The DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Self‐Powered Cardiac Pacemaker Enabled by Flexible Single Crystalline PMN‐PT Piezoelectric Energy Harvester
Open accessAbstract
A flexible single-crystalline PMN-PT piezoelectric energy harvester is demonstrated to achieve a self-powered artificial cardiac pacemaker. The energy-harvesting device generates a short-circuit current of 0.223 mA and an open-circuit voltage of 8.2 V, which are enough not only to meet the standard for charging commercial batteries but also for stimulating the heart without an external power source.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Alternative solutions for leadless devices have been proposed, including utilization of energy harvesters11, 12 and ultrasound-based wireless pacers8, 13, 14. However, these are similarly hindered by a large device size that leads to mechanically stressed fixation mechanisms.”
From Inductively powered wireless pacing via a miniature pacemaker and remote stimulation control system (2017) · cites this paper as [11]
Citations
Cites
Piezoelectric Nanogenerators Based on Zinc Oxide Nanowire Arrays
Wang, Z. L., & Song, J. (2006) · Science · doi:10.1126/science.1124005 · Cited by 7,922
Ferroelectric Ceramics: History and Technology
Haertling, G. H. (1999) · Journal of the American Ceramic Society · doi:10.1111/j.1151-2916.1999.tb01840.x · Cited by 4,103
Energy conservation in wireless sensor networks: A survey
Anastasi, G., Conti, M., Francesco, M. D., & Passarella, A. (2008) · Ad Hoc Networks · doi:10.1016/j.adhoc.2008.06.003 · Cited by 2,638
Dissolvable films of silk fibroin for ultrathin conformal bio-integrated electronics
Kim, D.-H., Viventi, J., Amsden, J. J., Xiao, J., Vigeland, L., Kim, Y.-S., Blanco, J. A., Panilaitis, B., Frechette, E. S., Contreras, D., et al. (2010) · Nature Materials · doi:10.1038/nmat2745 · Cited by 1,721
Xu, S., Qin, Y., Xu, C., Wei, Y., Yang, R., & Wang, Z. L. (2010) · Nature Nanotechnology · doi:10.1038/nnano.2010.46 · Cited by 1,640
Wang, S., Lin, L., & Wang, Z. L. (2012) · Nano Letters · doi:10.1021/nl303573d · Cited by 1,308
Power generation with laterally packaged piezoelectric fine wires
Yang, R., Qin, Y., Dai, L., & Wang, Z. L. (2008) · Nature Nanotechnology · doi:10.1038/nnano.2008.314 · Cited by 931
Piezoelectric BaTiO3Thin Film Nanogenerator on Plastic Substrates
Park, K., Xu, S., Liu, Y., Hwang, G., Kang, S. L., Wang, Z. L., & Lee, K. J. (2010) · Nano Letters · doi:10.1021/nl102959k · Cited by 831
Self-citationFlexible Nanocomposite Generator Made of BaTiO 3 Nanoparticles and Graphitic Carbons
Park, K., Lee, M. K., Liu, Y., Moon, S., Hwang, G., Zhu, G., Kim, J. E., Kim, S. O., Kim, D. K., Wang, Z. L., et al. (2012) · Advanced Materials · doi:10.1002/adma.201200105 · Cited by 712
Self-citationSelf‐Powered Nanosensors and Nanosystems
Wang, Z. L. (2011) · Advanced Materials · doi:10.1002/adma.201102958 · Cited by 710
Luo, H., Xu, G., Xu, H., Wang, P., & Yin, Z. (2000) · Japanese Journal of Applied Physics · doi:10.1143/jjap.39.5581 · Cited by 460
Park, S., Ahn, J., Feng, X., Wang, S., Huang, Y. Y., & Rogers, J. A. (2008) · Advanced Functional Materials · doi:10.1002/adfm.200800306 · Cited by 455
Choi, M., Choi, D., Jin, M., Kim, I.-S., Kim, S., Choi, J., Lee, S., Kim, J. M., & Kim, S. (2009) · Advanced Materials · doi:10.1002/adma.200803605 · Cited by 441
Self-citationSelf-Powered System with Wireless Data Transmission
Hu, Y., Zhang, Y., Xu, C., Lin, L., Snyder, R. L., & Wang, Z. L. (2011) · Nano Letters · doi:10.1021/nl201505c · Cited by 429
Transient, Biocompatible Electronics and Energy Harvesters Based on ZnO
Dagdeviren, C., Hwang, S., Su, Y., Kim, S., Cheng, H., Gur, O., Haney, R., Omenetto, F. G., Huang, Y., & Rogers, J. A. (2013) · Small · doi:10.1002/smll.201300146 · Cited by 412
Functional Electrical Stimulation by Nanogenerator with 58 V Output Voltage
Zhu, G., Wang, A. C., Liu, Y., Zhou, Y., & Wang, Z. L. (2012) · Nano Letters · doi:10.1021/nl300972f · Cited by 346
Flexible Piezoelectric PMN–PT Nanowire-Based Nanocomposite and Device
Xu, S., Yeh, Y., Poirier, G. R., McAlpine, M. C., Register, R. A., & Yao, N. (2013) · Nano Letters · doi:10.1021/nl400169t · Cited by 339
Flexible Fiber Nanogenerator with 209 V Output Voltage Directly Powers a Light-Emitting Diode
Gu, L., Cui, N., Cheng, L., Xu, Q., Bai, S., Yuan, M., Wu, W., Liu, J., Zhao, Y. S., Ma, F., et al. (2012) · Nano Letters · doi:10.1021/nl303539c · Cited by 307
Replacing a Battery by a Nanogenerator with 20 V Output
Hu, Y., Lin, L., Zhang, Y., & Wang, Z. L. (2011) · Advanced Materials · doi:10.1002/adma.201103727 · Cited by 290
Flexible Memristive Memory Array on Plastic Substrates
Kim, S., Jeong, H. Y., Kim, S., Choi, S., & Lee, K. J. (2011) · Nano Letters · doi:10.1021/nl203206h · Cited by 274
Self-citationJeong, C. K., Park, K., Ryu, J., Hwang, G., & Lee, K. J. (2014) · Advanced Functional Materials · doi:10.1002/adfm.201303484 · Cited by 247
Self-citationPark, K., Jeong, C. K., Ryu, J., Hwang, G., & Lee, K. J. (2013) · Advanced Energy Materials · doi:10.1002/aenm.201300458 · Cited by 245
Self-citationVirus-Directed Design of a Flexible BaTiO3 Nanogenerator
Jeong, C. K., Kim, I., Park, K., Oh, M. H., Paik, H., Hwang, G., No, K., Nam, Y. S., & Lee, K. J. (2013) · ACS Nano · doi:10.1021/nn404659d · Cited by 231
Self-citationSouthcott, M. A., MacVittie, K., Halámek, J., Halámková, L., Jemison, W. D., Lobel, R. M., & Katz, E. (2013) · Physical Chemistry Chemical Physics · doi:10.1039/c3cp50929j · Cited by 189
A high performance PZT ribbon-based nanogenerator using graphene transparent electrodes
Kwon, J., Seung, W., Sharma, B. K., Kim, S., & Ahn, J. (2012) · Energy & Environmental Science · doi:10.1039/c2ee22251e · Cited by 177
A brief history of cardiac pacing.
Nelson, G. (1993) · PubMed · Cited by 163
Large nonlinear dielectric properties of artificial BaTiO3/SrTiO3 superlattices
Kim, J., Kim, Y., Kim, Y. S., Lee, J., Kim, L., & Jung, D. (2002) · Applied Physics Letters · doi:10.1063/1.1477934 · Cited by 147
Self-citationAspect Ratio Dependence of the Elastic Properties of ZnO Nanobelts
Lucas, M., Mai, W., Yang, R., Wang, Z. L., & Riedo, E. (2007) · Nano Letters · doi:10.1021/nl070310g · Cited by 138
Hwang, G., Im, D., Lee, S., Lee, J., Koo, M. Y., Park, S. Y., Kim, S., Yang, K., Kim, S. J., Lee, K., et al. (2013) · ACS Nano · doi:10.1021/nn401246y · Cited by 127
Self-citationHigh-Performance Flexible Thin-Film Transistors Exfoliated from Bulk Wafer
Zhai, Y., Mathew, L., Rao, R. A., Xu, D., & Banerjee, S. K. (2012) · Nano Letters · doi:10.1021/nl302735f · Cited by 86
Cardiac Pacemaker Infection: Surgical Management With and Without Extracorporeal Circulation
Wilhelm, M. J., Schmid, Ç., Hammel, D., Kerber, S., Loick, H. M., Herrmann, M., & Scheld, H. H. (1997) · The Annals of Thoracic Surgery · doi:10.1016/s0003-4975(97)00989-2 · Cited by 81
Horlbeck, F., Mellert, F., Kreuz, J., Nickenig, G., & SCHWAB, J. O. (2012) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2012.02408.x · Cited by 72
Starzl, T. E., Gaertner, R. A., & Webb, R. C. (1955) · Circulation · doi:10.1161/01.cir.11.6.952 · Cited by 71
Kamba, S., Buixaderas, E., Petzelt, J., Fousek, J., Nosek, J., & Bridenbaugh, P. M. (2003) · Journal of Applied Physics · doi:10.1063/1.1528274 · Cited by 67
Growth and electrostrictive properties of Pb(Mg1/3Nb2/3)O3 crystals
Lee, S.-G., Monteiro, R. G., Feigelson, R. S., Lee, H. S., Lee, M., & Park, S.-E. (1999) · Applied Physics Letters · doi:10.1063/1.123445 · Cited by 53
Self-citationMond, H. G., Sloman, J. G., & EDWARDS, R. H. (1982) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1982.tb02226.x · Cited by 50
Large electrocaloric effect in highly (001)-oriented 0.67PbMg1/3Nb2/3O3–0.33PbTiO3 thin films
Feng, Z., Shi, D., & Dou, S. X. (2010) · Solid State Communications · doi:10.1016/j.ssc.2010.11.010 · Cited by 49
Baniecki, J. D., Laibowitz, R. B., Shaw, T. M., Saenger, K. L., Duncombe, P. R., Cabral, C., Kotecki, D. E., Shen, H., Lian, J., & Ma, Q. Y. (1999) · Journal of the European Ceramic Society · doi:10.1016/s0955-2219(98)00449-x · Cited by 46
(2012) · ISRN Materials Science · doi:10.5402/ms · Cited by 23
Fiber‐Based Hybrid Nanogenerators for/as Self‐Powered Systems in Biological Liquid
Pan, C., Li, Z., Guo, W., Zhu, J., & Wang, Z. L. (2011) · Angewandte Chemie · doi:10.1002/ange.201104197 · Cited by 16
Flagged first, then by citations
Research works printed but not linked: 8
- Nelson G. D., 1993, Texas Heart Institute Journal, 20, 12
- Mallela V. S., 2004, Indian Pacing and Electrophysiology J., 4, 201
- Wang X. D., 2013, Am. Ceram. Soc. Bull, 92, 18
- Park K.‐I., 2014, Adv. Mater., 26, 2154
- Bedell S. W., 2013, J. Phys. D Appl. Phys., 46
- Chen L. P., 2011, Epl‐Europhys. Lett., 93
- Henderson I. R., 2006, Piezoelectric Ceramics: Principles and Applications
- Tian J., 2007, IEEE T. on, 54, 1895
Cited by
Sorted by citations
Flexible Nanogenerators for Energy Harvesting and Self‐Powered Electronics
Fan, F. R., Tang, W., & Wang, Z. L. (2016) · Advanced Materials · doi:10.1002/adma.201504299 · Cited by 1,933
A comprehensive review on the state-of-the-art of piezoelectric energy harvesting
Sezer, N., & Koç, M. (2020) · Nano Energy · doi:10.1016/j.nanoen.2020.105567 · Cited by 1,539
High-Performance Piezoelectric Energy Harvesters and Their Applications
Yang, Z., Zhou, S., Zu, J. W.-Z., & Inman, D. J. (2018) · Joule · doi:10.1016/j.joule.2018.03.011 · Cited by 1,280
Smart Textiles for Electricity Generation
Chen, G., Li, Y., Bick, M., & Chen, J. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00821 · Cited by 940
Device integration of electrochemical biosensors
Wu, J., Liu, H., Chen, W., Ma, B., & Ju, H. (2023) · Nature Reviews Bioengineering · doi:10.1038/s44222-023-00032-w · Cited by 995
Metadata
- Authors
- Hwang, G., Park, H., Lee, J., Oh, S., Park, K., Byun, M., Park, H., Ahn, G., Jeong, C. K., No, K., Kwon, H., Lee, S., Joung, B., & Lee, K. J.
- Affiliations
- Korea Advanced Institute of Science and Technology (KR)
- Yonsei University (KR)
- Ibule Photonics (South Korea) (KR)
- Corresponding author
- Lee, Keon Jae
- ORCID
- Venue
- Advanced Materials
- Publisher
- Wiley
- Published
- 2014-04-17
- Volume
- 26
- Issue
- 28
- Pages
- 4880-4887
- ISSN
- 0935-9648 (ISSN-L)
- 1521-4095
- OpenAlex
- W1968395095
- Cited by
- 672
- References
- 40
- Citations by year
- 2026: 24 · 2025: 36 · 2024: 46 · 2023: 55 · 2022: 67 · 2021: 64 · 2020: 76 · 2019: 73 · 2018: 75 · 2017: 66 · 2016: 47 · 2015: 33 · 2014: 10
- FWCI
- 60.54
- Type
- journal article
- Language
- en
- Open access
- Licence
- Locations
- Advanced Materials (publishedVersion)
- PubMed (publishedVersion)
- YUHSpace (Yonsei University Medical Library) (submittedVersion, cc-by-nc-nd)
- Topics
- Physical Sciences › Engineering › Mechanical Engineering › Innovative Energy Harvesting Technologies
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Physical Sciences › Materials Science › Materials Chemistry › Ferroelectric and Piezoelectric Materials
- Keywords
- PMN-PT single crystal, piezoelectric energy harvesting, flexible energy harvester, biomedical implants, cardiac pacing, battery charging, piezoelectric materials
- MeSH terms
- Crystallization, Energy Transfer, Equipment Design, Lead, Materials Testing, Niobium, Oxides, Pacemaker, Artificial, Electric Power Supplies, Titanium, Equipment Failure Analysis, Prostheses and Implants, Elastic Modulus, Micro-Electrical-Mechanical Systems
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review