The DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Self‐Powered Cardiac Pacemaker Enabled by Flexible Single Crystalline PMN‐PT Piezoelectric Energy Harvester
Open accessAbstract
A flexible single-crystalline PMN-PT piezoelectric energy harvester is demonstrated to achieve a self-powered artificial cardiac pacemaker. The energy-harvesting device generates a short-circuit current of 0.223 mA and an open-circuit voltage of 8.2 V, which are enough not only to meet the standard for charging commercial batteries but also for stimulating the heart without an external power source.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Alternative solutions for leadless devices have been proposed, including utilization of energy harvesters11, 12 and ultrasound-based wireless pacers8, 13, 14. However, these are similarly hindered by a large device size that leads to mechanically stressed fixation mechanisms.”
From Inductively powered wireless pacing via a miniature pacemaker and remote stimulation control system (2017) · cites this paper as [11]
Citations
Cites
Piezoelectric Nanogenerators Based on Zinc Oxide Nanowire Arrays
Wang, Z. L., & Song, J. (2006) · Science · doi:10.1126/science.1124005 · Cited by 7,922
Ferroelectric Ceramics: History and Technology
Haertling, G. H. (1999) · Journal of the American Ceramic Society · doi:10.1111/j.1151-2916.1999.tb01840.x · Cited by 4,103
Energy conservation in wireless sensor networks: A survey
Anastasi, G., Conti, M., Francesco, M. D., & Passarella, A. (2008) · Ad Hoc Networks · doi:10.1016/j.adhoc.2008.06.003 · Cited by 2,638
Dissolvable films of silk fibroin for ultrathin conformal bio-integrated electronics
Kim, D.-H., Viventi, J., Amsden, J. J., Xiao, J., Vigeland, L., Kim, Y.-S., Blanco, J. A., Panilaitis, B., Frechette, E. S., Contreras, D., et al. (2010) · Nature Materials · doi:10.1038/nmat2745 · Cited by 1,721
Xu, S., Qin, Y., Xu, C., Wei, Y., Yang, R., & Wang, Z. L. (2010) · Nature Nanotechnology · doi:10.1038/nnano.2010.46 · Cited by 1,640
Wang, S., Lin, L., & Wang, Z. L. (2012) · Nano Letters · doi:10.1021/nl303573d · Cited by 1,308
Power generation with laterally packaged piezoelectric fine wires
Yang, R., Qin, Y., Dai, L., & Wang, Z. L. (2008) · Nature Nanotechnology · doi:10.1038/nnano.2008.314 · Cited by 931
Piezoelectric BaTiO3Thin Film Nanogenerator on Plastic Substrates
Park, K., Xu, S., Liu, Y., Hwang, G., Kang, S. L., Wang, Z. L., & Lee, K. J. (2010) · Nano Letters · doi:10.1021/nl102959k · Cited by 831
Self-citationFlexible Nanocomposite Generator Made of BaTiO 3 Nanoparticles and Graphitic Carbons
Park, K., Lee, M. K., Liu, Y., Moon, S., Hwang, G., Zhu, G., Kim, J. E., Kim, S. O., Kim, D. K., Wang, Z. L., et al. (2012) · Advanced Materials · doi:10.1002/adma.201200105 · Cited by 712
Self-citationSelf‐Powered Nanosensors and Nanosystems
Wang, Z. L. (2011) · Advanced Materials · doi:10.1002/adma.201102958 · Cited by 710
Flagged first, then by citations
Research works printed but not linked: 8
- Nelson G. D., 1993, Texas Heart Institute Journal, 20, 12
- Mallela V. S., 2004, Indian Pacing and Electrophysiology J., 4, 201
- Wang X. D., 2013, Am. Ceram. Soc. Bull, 92, 18
- Park K.‐I., 2014, Adv. Mater., 26, 2154
- Bedell S. W., 2013, J. Phys. D Appl. Phys., 46
- Chen L. P., 2011, Epl‐Europhys. Lett., 93
- Henderson I. R., 2006, Piezoelectric Ceramics: Principles and Applications
- Tian J., 2007, IEEE T. on, 54, 1895
Cited by
Sorted by citations
Flexible Nanogenerators for Energy Harvesting and Self‐Powered Electronics
Fan, F. R., Tang, W., & Wang, Z. L. (2016) · Advanced Materials · doi:10.1002/adma.201504299 · Cited by 1,933
A comprehensive review on the state-of-the-art of piezoelectric energy harvesting
Sezer, N., & Koç, M. (2020) · Nano Energy · doi:10.1016/j.nanoen.2020.105567 · Cited by 1,539
High-Performance Piezoelectric Energy Harvesters and Their Applications
Yang, Z., Zhou, S., Zu, J. W.-Z., & Inman, D. J. (2018) · Joule · doi:10.1016/j.joule.2018.03.011 · Cited by 1,280
Smart Textiles for Electricity Generation
Chen, G., Li, Y., Bick, M., & Chen, J. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00821 · Cited by 940
Device integration of electrochemical biosensors
Wu, J., Liu, H., Chen, W., Ma, B., & Ju, H. (2023) · Nature Reviews Bioengineering · doi:10.1038/s44222-023-00032-w · Cited by 995
Metadata
- Authors
- Hwang, G., Park, H., Lee, J., Oh, S., Park, K., Byun, M., Park, H., Ahn, G., Jeong, C. K., No, K., Kwon, H., Lee, S., Joung, B., & Lee, K. J.
- Affiliations
- Korea Advanced Institute of Science and Technology (KR)
- Yonsei University (KR)
- Ibule Photonics (South Korea) (KR)
- Corresponding author
- Lee, Keon Jae
- ORCID
- Venue
- Advanced Materials
- Publisher
- Wiley
- Published
- 2014-04-17
- Volume
- 26
- Issue
- 28
- Pages
- 4880-4887
- ISSN
- 0935-9648 (ISSN-L)
- 1521-4095
- OpenAlex
- W1968395095
- Cited by
- 672
- References
- 40
- Citations by year
- 2026: 24 · 2025: 36 · 2024: 46 · 2023: 55 · 2022: 67 · 2021: 64 · 2020: 76 · 2019: 73 · 2018: 75 · 2017: 66 · 2016: 47 · 2015: 33 · 2014: 10
- FWCI
- 60.54
- Type
- journal article
- Language
- en
- Open access
- Licence
- Locations
- Advanced Materials (publishedVersion)
- PubMed (publishedVersion)
- YUHSpace (Yonsei University Medical Library) (submittedVersion, cc-by-nc-nd)
- Topics
- Physical Sciences › Engineering › Mechanical Engineering › Innovative Energy Harvesting Technologies
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Physical Sciences › Materials Science › Materials Chemistry › Ferroelectric and Piezoelectric Materials
- Keywords
- PMN-PT single crystal, piezoelectric energy harvesting, flexible energy harvester, biomedical implants, cardiac pacing, battery charging, piezoelectric materials
- MeSH terms
- Crystallization, Energy Transfer, Equipment Design, Lead, Materials Testing, Niobium, Oxides, Pacemaker, Artificial, Electric Power Supplies, Titanium, Equipment Failure Analysis, Prostheses and Implants, Elastic Modulus, Micro-Electrical-Mechanical Systems
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review