CoChat

High Performance Conducting Polymer Nanofiber Biosensors for Detection of Biomolecules

Open access
Yang, Guang, Kampstra, Kelly L., Abidian, Mohammad Reza · 2014 · Advanced Materials
Cited by 141

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Sensitive detection and selective determination of the physiologically important chemicals involved in brain function have drawn much attention for the diagnosis and treatment of brain diseases and neurological disorders. This paper reports a novel method for fabrication of enzyme entrapped-conducting polymer nanofibers that offer higher sensitivity and increased lifetime compared to glucose sensors that are based on conducting polymer films.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/adma.201400753

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 141

Metadata

Authors
Yang, G., Kampstra, K. L., & Abidian, M. R.
Venue
Advanced Materials
Publisher
Wiley
Published
2014-04-09
Volume
26
Issue
29
Pages
4954-4960
ISSN
  • 0935-9648 (ISSN-L)
  • 1521-4095
OpenAlex
W2047656177
Cited by
141
References
4
FWCI
9.20
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: High Performance Conducting Polymer Nanofiber Biosensors for Detection of Biomolecules. https://app.cochat.ai/papers/10.1002/adma.201400753
The paper
Yang, G., Kampstra, K. L., & Abidian, M. R. (2014). High Performance Conducting Polymer Nanofiber Biosensors for Detection of Biomolecules. Advanced Materials. https://doi.org/10.1002/adma.201400753

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.