The DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.
MOF Thin Film‐Coated Metal Oxide Nanowire Array: Significantly Improved Chemiresistor Sensor Performance
Abstract
A strategy for combining metal oxides and metal-organic frameworks is proposed to design new materials for sensing volatile organic compounds, for the first time. The prepared ZnO@ZIF-CoZn core-sheath nanowire arrays show greatly enhanced performance not only on its selectivity but also on its response, recovery behavior, and working temperature.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Chromium Terephthalate-Based Solid with Unusually Large Pore Volumes and Surface Area
Férey, G., Mellot-Draznieks, C., Serre, C., Millange, F., Dutour, J., Surblé, S., & Margiolaki, I. (2005) · Science · doi:10.1126/science.1116275 · Cited by 5,430
Interpenetrating Nets: Ordered, Periodic Entanglement
Batten, S. R., & Robson, R. (1998) · Angewandte Chemie International Edition · doi:10.1002/(sici)1521-3773(19980619)37:11<1460::aid-anie1460>3.0.co;2-z · Cited by 4,337
Metal Oxide Gas Sensors: Sensitivity and Influencing Factors
Wang, C., Yin, L., Zhang, L., Xiang, D., & Gao, R. (2010) · Sensors · doi:10.3390/s100302088 · Cited by 2,928
A route to high surface area, porosity and inclusion of large molecules in crystals
Materials Design and Discovery Group, Chae, H. K., Siberio-Pérez, D. Y., Kim, J., Go, Y., Eddaoudi, M., Matzger, A. J., O'Keeffe, M., & Yaghi, O. M. (2004) · Nature · doi:10.1038/nature02311 · Cited by 2,816
Highly sensitive and selective gas sensors using p-type oxide semiconductors: Overview
Kim, H.-J., & Lee, J.-H. (2014) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2013.11.005 · Cited by 2,258
General Route to Vertical ZnO Nanowire Arrays Using Textured ZnO Seeds
Greene, L. E., Law, M., Tan, D. H., Montano, M., Goldberger, J., Somorjai, G., & Yang, P. (2005) · Nano Letters · doi:10.1021/nl050788p · Cited by 1,442
Electronic Nose: Current Status and Future Trends
Röck, F., Barsan, N., & Weimar, U. (2008) · Chemical Reviews · doi:10.1021/cr068121q · Cited by 1,437
Campbell, M. G., Sheberla, D., Liu, S. F., Swager, T. M., & Dincă, M. (2015) · Angewandte Chemie International Edition · doi:10.1002/anie.201411854 · Cited by 1,063
Chemiresistive Sensor Arrays from Conductive 2D Metal–Organic Frameworks
Campbell, M. G., Liu, S. F., Swager, T. M., & Dincă, M. (2015) · Journal of the American Chemical Society · doi:10.1021/jacs.5b09600 · Cited by 852
Zhang, L., Su, Z., Jiang, F., Yang, L., Qian, J., Zhou, Y., Li, W., & Hong, M. (2014) · Nanoscale · doi:10.1039/c4nr00348a · Cited by 814
Cited by
Xu, G.-R., An, Z.-H., Xu, K., Liu, Q., Das, R., & Zhao, H.-L. (2021) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2020.213554 · Cited by 379
Self-citationNanoparticles as Next-Generation Tooth-Whitening Agents: Progress and Perspectives
Kim, D.-H., Bae, J., Heo, J. H., Park, C. H., Kim, E. B., & Lee, J. H. (2022) · ACS Nano · doi:10.1021/acsnano.2c01412 · Cited by 50
Metadata
- Authors
- Yao, M., Tang, W., Wang, G., Nath, B., & Xu, G.
- Venue
- Advanced Materials
- Publisher
- Wiley
- Published
- 2016-05-06
- Volume
- 28
- Issue
- 26
- Pages
- 5229-5234
- ISSN
- 0935-9648 (ISSN-L)
- 1521-4095
- OpenAlex
- W2346338627
- Cited by
- 641
- References
- 39
- FWCI
- 26.68
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: MOF Thin Film‐Coated Metal Oxide Nanowire Array: Significantly Improved Chemiresistor Sensor Performance. https://app.cochat.ai/papers/10.1002/adma.201506457
- The paper
- Yao, M., Tang, W., Wang, G., Nath, B., & Xu, G. (2016). MOF Thin Film‐Coated Metal Oxide Nanowire Array: Significantly Improved Chemiresistor Sensor Performance. Advanced Materials. https://doi.org/10.1002/adma.201506457
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.