Stretchable E‐Skin Apexcardiogram Sensor
Abstract
A new strategy to measure the apex cardiogram with electronic skin technology is presented. An electronic skin apexcardiogram sensor, which can compensate the conventional electrocardiogram for cardiac diagnosis, is demonstrated through a highly sensitive and stretchable strain sensor with gold-nanoparticle composites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In a variety of heart diseases, continuous, unobtrusive cardiac monitoring may detect disease onset or decline earlier, enabling earlier detection and intervention, and thus potentially improving outcomes.
“In a variety of heart diseases, continuous, unobtrusive cardiac monitoring may detect disease onset or decline earlier, enabling earlier detection and intervention, and thus potentially improving outcomes.”
From A Chest‐Conformable, Wireless Electro‐Mechanical E‐Tattoo for Measuring Multiple Cardiac Time Intervals (2023) · cites this paper as [3]
The ACG waveform clearly indicated all the characteristic peaks, providing valuable information for cardiac diagnosis.
“The ACG waveform clearly indicated all the characteristic peaks, providing valuable information for cardiac diagnosis.”
From Nanomaterial-Enabled Wearable Sensors for Healthcare (2018) · cites this paper as [115]
An AuNP-based resistive strain sensor was used in detecting the temporal changes of volume and pressure in the heart under normal state and after exercise.
“Figure 9a depicts the application of an AuNP-based resistive strain sensor in detecting the temporal changes of volume and pressure in the heart under normal state and after exercise.[115]”
From Nanomaterial-Enabled Wearable Sensors for Healthcare (2018) · cites this paper as [115]
The citation lists haven’t been fetched yet
References 27 · Cited by 213
- Authors
- You, I., Kim, B., Park, J., Koh, K., Shin, S., Jung, S., & Jeong, U.
- Affiliations
- Pohang University of Science and Technology (KR)
- Yonsei University (KR)
- Corresponding author
- Jeong, Unyong
- Venue
- Advanced Materials
- Publisher
- Wiley
- Published
- 2016-05-11
- Volume
- 28
- Issue
- 30
- Pages
- 6359-6364
- ISSN
- 0935-9648 (ISSN-L)
- 1521-4095
- OpenAlex
- W2391213063
- Cited by
- 213
- References
- 27
- Citations by year
- 2026: 2 · 2025: 11 · 2024: 19 · 2023: 23 · 2022: 25 · 2021: 23 · 2020: 32 · 2019: 28 · 2018: 29 · 2017: 19 · 2016: 2
- FWCI
- 12.51
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Advanced Materials (publishedVersion)
- PubMed (publishedVersion)
- Open Access System for Information Sharing (Pohang University of Science and Technology) (submittedVersion)
- Funders
- Samsung (SRFC‐MA1301‐07)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Nanomaterials and Printing Technologies
- Keywords
- electronic skin, apexcardiogram, stretchable strain sensors, electrocardiogram, heart disease diagnosis, wearable sensors
- MeSH terms
- Wearable Electronic Devices, Adult, Gold, Heart Diseases, Humans, Kinetocardiography, Male, Sensitivity and Specificity, Metal Nanoparticles
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review