The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
High‐Performance Next‐Generation Perovskite Nanocrystal Scintillator for Nondestructive X‐Ray Imaging
Abstract
Readily commercializable and cost‐effective next‐generation CsPbBr 3 perovskite nanocrystals (PNCs) based X‐ray detectors are demonstrated. The PNCs‐based X‐ray detector exhibits higher spatial resolution (9.8 lp mm−1 at modulation transfer function (MTF) = 0.2 and 12.5–8.9 lp mm−1 for a linear line chart), faster response time (≈200 ns), and comparable stability (>40 Gy air s−1 of X‐ray exposure) compared with the commercialized terbium‐doped gadolinium oxysulfide (GOS)‐based detectors (spatial resolution = 6.2 lp mm−1 at MTF = 0.2 and 6.3 lp mm−1 for a linear line chart, response time = ≈1200 ns) because the PNCs‐based scintillator has ≈5.6‐fold faster average photoluminescence lifetime and stronger emission than the GOS‐based one.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Protesescu, L., Yakunin, S., Bodnarchuk, M. I., Krieg, F., Caputo, R., Hendon, C. H., Yang, R. X., Walsh, A., & Kovalenko, M. V. (2015) · Nano Letters · doi:10.1021/nl5048779 · Cited by 9,209
Sensitive X-ray detectors made of methylammonium lead tribromide perovskite single crystals
Wei, H., Fang, Y., Mulligan, P., Chuirazzi, W., Fang, H.-H., Wang, C., Ecker, B. R., Gao, Y., Loi, M. A., Cao, L., et al. (2016) · Nature Photonics · doi:10.1038/nphoton.2016.41 · Cited by 1,877
Stoumpos, C. C., Malliakas, C. D., Peters, J. A., Liu, Z., Sebastian, M., Im, J., Chasapis, T. C., Wibowo, A. C., Chung, D. Y., Freeman, A. J., et al. (2013) · Crystal Growth & Design · doi:10.1021/cg400645t · Cited by 1,596
Printable organometallic perovskite enables large-area, low-dose X-ray imaging
Kim, Y. C., Kim, K. H., Son, D.-Y., Jeong, D.-N., Seo, J.-Y., Choi, Y. S., Han, I. T., Lee, S. Y., & Park, N.-G. (2017) · Nature · doi:10.1038/nature24032 · Cited by 1,206
Self-citationDetection of X-ray photons by solution-processed lead halide perovskites
Yakunin, S., Sytnyk, M., Kriegner, D., Shrestha, S., Richter, M., Matt, G. J., Azimi, H., Brabec, C. J., Stangl, J., Kovalenko, M. V., et al. (2015) · Nature Photonics · doi:10.1038/nphoton.2015.82 · Cited by 1,184
Colloidal CsPbBr3 Perovskite Nanocrystals: Luminescence beyond Traditional Quantum Dots
Swarnkar, A., Chulliyil, R., Ravi, V. K., Irfanullah, M., Chowdhury, A., & Nag, A. (2015) · Angewandte Chemie International Edition · doi:10.1002/anie.201508276 · Cited by 996
X-ray detectors for digital radiography
Yaffe, M. J., & Rowlands, J. A. (1997) · Physics in Medicine and Biology · doi:10.1088/0031-9155/42/1/001 · Cited by 694
Rieder, R., Economou, T., Wänke, H., Turkevich, A., Crisp, J., Brückner, J., Dreibus, G., & McSween, H. Y. (1997) · Science · doi:10.1126/science.278.5344.1771 · Cited by 607
CdZnTe and CdTe materials for X‐ray and gamma ray radiation detector applications
Szeles, C. (2004) · physica status solidi (b) · doi:10.1002/pssb.200304296 · Cited by 469
Blasse, G. (1994) · Chemistry of Materials · doi:10.1021/cm00045a002 · Cited by 361
Cited by
Surface Chemistry Engineering of Perovskite Quantum Dots: Strategies, Applications, and Perspectives
Bai, Y., Hao, M., Ding, S., Chen, P., & Wang, L. (2022) · Advanced Materials · doi:10.1002/adma.202105958 · Cited by 394
Cao, F., Yu, D., Ma, W., Xu, X., Cai, B., Yang, Y. M., Liu, S., He, L., Ke, Y., Lan, S., et al. (2020) · ACS Nano · doi:10.1021/acsnano.9b06114 · Cited by 322
Ma, W., Jiang, T., Yang, Z., Zhang, H., Su, Y., Chen, Z., Chen, X., Ma, Y., Zhu, W., Yu, X., et al. (2021) · Advanced Science · doi:10.1002/advs.202003728 · Cited by 322
Recent Advances in Perovskite Photodetectors for Image Sensing
Li, L., Ye, S., Qu, J., Zhou, F., Song, J., & Shen, G. (2021) · Small · doi:10.1002/smll.202005606 · Cited by 235
Emerging New-Generation Photodetectors Based on Low-Dimensional Halide Perovskites
Wang, Y., Song, L., Chen, Y., & Huang, W. (2020) · ACS Photonics · doi:10.1021/acsphotonics.9b01233 · Cited by 156
Metadata
- Authors
- Heo, J. H., Shin, D. H., Park, J. K., Kim, D. H., Lee, S. J., & Im, S. H.
- Venue
- Advanced Materials
- Publisher
- Wiley
- Published
- 2018-08-23
- Volume
- 30
- Issue
- 40
- Pages
- e1801743-e1801743
- ISSN
- 0935-9648 (ISSN-L)
- 1521-4095
- OpenAlex
- W2888364028
- Cited by
- 523
- References
- 13
- FWCI
- 29.51
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High‐Performance Next‐Generation Perovskite Nanocrystal Scintillator for Nondestructive X‐Ray Imaging. https://app.cochat.ai/papers/10.1002/adma.201801743
- The paper
- Heo, J. H., Shin, D. H., Park, J. K., Kim, D. H., Lee, S. J., & Im, S. H. (2018). High‐Performance Next‐Generation Perovskite Nanocrystal Scintillator for Nondestructive X‐Ray Imaging. Advanced Materials. https://doi.org/10.1002/adma.201801743
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.