The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Detection of X-ray photons by solution-processed lead halide perovskites
Open accessAbstract
The evolution of real-time medical diagnostic tools such as angiography and computer tomography from radiography based on photographic plates was enabled by the development of integrated solid-state X-ray photon detectors made from conventional solid-state semiconductors. Recently, for optoelectronic devices operating in the visible and near-infrared spectral regions, solution-processed organic and inorganic semiconductors have also attracted a great deal of attention. Here, we demonstrate a possibility to use such inexpensive semiconductors for the sensitive detection of X-ray photons by direct photon-to-current conversion. In particular, methylammonium lead iodide perovskite (CH3NH3PbI3) offers a compelling combination of fast photoresponse and a high absorption cross-section for X-rays, owing to the heavy Pb and I atoms. Solution-processed photodiodes as well as photoconductors are presented, exhibiting high values of X-ray sensitivity (up to 25 μC mGyair−1 cm−3) and responsivity (1.9 × 104 carriers/photon), which are commensurate with those obtained by the current solid-state technology. Solid-state X-ray detectors have enabled real-time diagnostics as well as reduced patient dose. Now researchers have shown that potentially inexpensive perovskites can be used for efficient X-ray imaging.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Stranks, S. D., Eperon, G. E., Grancini, G., Menelaou, C., Alcocer, M. J. P., Leijtens, T., Herz, L. M., Petrozza, A., & Snaith, H. J. (2013) · Science · doi:10.1126/science.1243982 · Cited by 10,413
Mid-infrared HgTe colloidal quantum dot photodetectors
Keuleyan, S., Lhuillier, E., Brajuskovic, V., & Guyot-Sionnest, P. (2011) · Nature Photonics · doi:10.1038/nphoton.2011.142 · Cited by 503
Cited by
Solution-processed semiconductors for next-generation photodetectors
García de Arquer, F. P., Armin, A., Meredith, P., & Sargent, E. H. (2017) · Nature Reviews Materials · doi:10.1038/natrevmats.2016.100 · Cited by 1,529
Ahmadi, M., Wu, T., & Hu, B. (2017) · Advanced Materials · doi:10.1002/adma.201605242 · Cited by 820
Yettapu, G. R., Talukdar, D., Sarkar, S., Swarnkar, A., Nag, A., Ghosh, P., & Mandal, P. (2016) · Nano Letters · doi:10.1021/acs.nanolett.6b01168 · Cited by 594
Han, T.-H., Lee, J.-W., Choi, C., Tan, S., Lee, C., Zhao, Y., Dai, Z., De Marco, N., Lee, S.-J., Bae, S.-H., et al. (2019) · Nature Communications · doi:10.1038/s41467-019-08455-z · Cited by 588
Heo, J. H., Shin, D. H., Park, J. K., Kim, D. H., Lee, S. J., & Im, S. H. (2018) · Advanced Materials · doi:10.1002/adma.201801743 · Cited by 523
Metadata
- Authors
- Yakunin, S., Sytnyk, M., Kriegner, D., Shrestha, S., Richter, M., Matt, G. J., Azimi, H., Brabec, C. J., Stangl, J., Kovalenko, M. V., & Heiss, W.
- Venue
- Nature Photonics
- Published
- 2015-05-25
- Volume
- 9
- Issue
- 7
- Pages
- 444-449
- ISSN
- 1749-4885 (ISSN-L)
- 1749-4893
- OpenAlex
- W1517556801
- Cited by
- 1,184
- References
- 2
- FWCI
- 38.65
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Detection of X-ray photons by solution-processed lead halide perovskites. https://app.cochat.ai/papers/10.1038/nphoton.2015.82
- The paper
- Yakunin, S., Sytnyk, M., Kriegner, D., Shrestha, S., Richter, M., Matt, G. J., Azimi, H., Brabec, C. J., Stangl, J., Kovalenko, M. V., & Heiss, W. (2015). Detection of X-ray photons by solution-processed lead halide perovskites. Nature Photonics. https://doi.org/10.1038/nphoton.2015.82
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.