Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 243

The DOI matches its Crossref record.

Photophysical Pathways in Highly Sensitive Cs2AgBiBr6 Double‐Perovskite Single‐Crystal X‐Ray Detectors

Open access
Steele, Julian A., Pan, Weicheng, Martin, Cristina, Keshavarz, Masoumeh, Debroye, Elke, Yuan, Haifeng, Banerjee, Subhasree, Fron, Eduard, Jonckheere, Dries, Kim, Cheol Woong, Baekelant, Wouter, Niu, Guangda, Tang, Jiang, Vanacken, Johan, Van der Auweraer, Mark, Hofkens, Johan, Roeffaers, Maarten B. J.·2018·Advanced Materials

Abstract

The sensitive detection of X‐rays embodies an important research area, being motivated by a common desire to minimize the radiation doses required for detection. Among metal halide perovskites, the double‐perovskite Cs 2 AgBiBr 6 system has emerged as a promising candidate for the detection of X‐rays, capable of high X‐ray stability and sensitivity (105 μC Gy−1 cm−2). Herein, the important photophysical pathways in single‐crystal Cs 2 AgBiBr 6 are detailed at both room (RT) and liquid‐nitrogen (LN 2 T) temperatures, with emphasis made toward understanding the carrier dynamics that influence X‐ray sensitivity. This study draws upon several optical probes and an RT excitation model is developed which is far from optimal, being plagued by a large trap density and fast free‐carrier recombination pathways. Substantially improved operating conditions are revealed at 77 K, with a long fundamental carrier lifetime (>1.5 µs) and a marked depopulation of parasitic recombination pathways. The temperature dependence of a single‐crystal Cs 2 AgBiBr 6 X‐ray detecting device is characterized and a strong and monotonic enhancement to the X‐ray sensitivity upon cooling is demonstrated, moving from 316 μC Gy−1 cm−2 at RT to 988 μC Gy−1 cm−2 near LN 2 T. It is concluded that even modest cooling—via a Peltier device—will facilitate a substantial enhancement in device performance, ultimately lowering the radiation doses required.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/adma.201804450

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 243

Metadata

Authors
Steele, J. A., Pan, W., Martin, C., Keshavarz, M., Debroye, E., Yuan, H., Banerjee, S., Fron, E., Jonckheere, D., Kim, C. W., Baekelant, W., Niu, G., Tang, J., Vanacken, J., Van der Auweraer, M., Hofkens, J., & Roeffaers, M. B. J.
Venue
Advanced Materials
Publisher
Wiley
Published
2018-09-17
Volume
30
Issue
46
Pages
e1804450-e1804450
ISSN
  • 0935-9648 (ISSN-L)
  • 1521-4095
OpenAlex
W2891964245
Cited by
243
References
0
FWCI
21.54
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Photophysical Pathways in Highly Sensitive Cs2AgBiBr6 Double‐Perovskite Single‐Crystal X‐Ray Detectors. https://app.cochat.ai/papers/10.1002/adma.201804450
The paper
Steele, J. A., Pan, W., Martin, C., Keshavarz, M., Debroye, E., Yuan, H., Banerjee, S., Fron, E., Jonckheere, D., Kim, C. W., Baekelant, W., Niu, G., Tang, J., Vanacken, J., Van der Auweraer, M., Hofkens, J., & Roeffaers, M. B. J. (2018). Photophysical Pathways in Highly Sensitive Cs2AgBiBr6 Double‐Perovskite Single‐Crystal X‐Ray Detectors. Advanced Materials. https://doi.org/10.1002/adma.201804450

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.