The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Multicenter Metal–Organic Framework‐Based Ratiometric Fluorescent Sensors
Abstract
Metal–organic frameworks (MOFs) with multiple emission centers are newly emerging as ratiometric sensors owing to their high sensitivity and high selectivity toward a wide range of targeted functional species. Energy transfer between the light‐absorbing group and emission centers and between different emission centers is the key to rationally design and synthesize MOF‐based ratiometric sensors. A good match between the energy levels of the light‐absorbing groups and emission centers is the prerequisite for MOF‐based sensors to exhibit multiple emissions, and a good match of the MOF‐based sensors and those of the targeted species can increase the sensitivity and selectivity, but this match is highly challenging to obtain via synthesis. MOFs with multiple emission centers can be produced by functionalizing MOFs with multiple lanthanide centers, organic luminophores, dyes, carbon dots, and other such emissive groups. In this progress report, recent advances in the strategies for synthesizing MOFs with multiple emission centers and their applications for ratiometric sensing of solution conditions, including the pH value, and ion, organic molecule, and biomolecule concentrations, are summarized, as are the related sensing mechanisms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
H 2 S as a Physiologic Vasorelaxant: Hypertension in Mice with Deletion of Cystathionine γ-Lyase
Yang, G., Wu, L., Jiang, B., Yang, W., Qi, J., Cao, K., Meng, Q., Mustafa, A. K., Mu, W., Zhang, S., et al. (2008) · Science · doi:10.1126/science.1162667 · Cited by 2,310
Cogliano, V. J., Grosse, Y., Baan, R. A., Straif, K., Secretan, M. B., Ghissassi, F. E., & the Working Group for Volume 88 (2005) · Environmental Health Perspectives · doi:10.1289/ehp.7542 · Cited by 375
Metal based neurodegenerative diseases—From molecular mechanisms to therapeutic strategies
Crichton, R. R., Dexter, D. T., & Ward, R. J. (2008) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2007.10.019 · Cited by 252
Cited by
Rare-Earth Doping in Nanostructured Inorganic Materials
Zheng, B., Fan, J., Chen, B., Qin, X., Wang, J., Wang, F., Deng, R., & Liu, X. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00644 · Cited by 1,204
Bimetallic metal–organic frameworks and their derivatives
Chen, L., Wang, H.-F., Li, C., & Xu, Q. (2020) · Chemical Science · doi:10.1039/d0sc01432j · Cited by 639
Metal-organic frameworks (MOFs) and MOF composites based biosensors
Mohanty, B., Kumari, S., Yadav, P., Kanoo, P., & Chakraborty, A. (2024) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2024.216102 · Cited by 440
Energy Transfer in Metal–Organic Frameworks for Fluorescence Sensing
Wang, J.-X., Yin, J., Shekhah, O., Bakr, O. M., Eddaoudi, M., & Mohammed, O. F. (2022) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.1c24759 · Cited by 300
Metadata
- Authors
- Wu, S., Min, H., Shi, W., & Cheng, P.
- Venue
- Advanced Materials
- Publisher
- Wiley
- Published
- 2019-02-21
- Volume
- 32
- Issue
- 3
- Pages
- e1805871-e1805871
- ISSN
- 0935-9648 (ISSN-L)
- 1521-4095
- OpenAlex
- W2916719623
- Cited by
- 712
- References
- 3
- FWCI
- 32.51
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Multicenter Metal–Organic Framework‐Based Ratiometric Fluorescent Sensors. https://app.cochat.ai/papers/10.1002/adma.201805871
- The paper
- Wu, S., Min, H., Shi, W., & Cheng, P. (2020). Multicenter Metal–Organic Framework‐Based Ratiometric Fluorescent Sensors. Advanced Materials. https://doi.org/10.1002/adma.201805871
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.