The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Built‐In Active Microneedle Patch with Enhanced Autonomous Drug Delivery
Open accessAbstract
The use of microneedles has facilitated the painless localized delivery of drugs across the skin. However, their efficacy has been limited by slow diffusion of molecules and often requires external triggers. Herein, an autonomous and degradable, active microneedle delivery platform is introduced, employing magnesium microparticles loaded within the microneedle patch, as the built‐in engine for deeper and faster intradermal payload delivery. The magnesium particles react with the interstitial fluid, leading to an explosive‐like rapid production of H 2 bubbles, providing the necessary force to breach dermal barriers and enhance payload delivery. The release kinetics of active microneedles is evaluated in vitro by measuring the amount of IgG antibody (as a model drug) that passed through phantom tissue and a pigskin barrier. In vivo experiments using a B16F10 mouse melanoma model demonstrate that the active delivery of anti‐CTLA‐4 (a checkpoint inhibitor drug) results in greatly enhanced immune response and significantly longer survival. Moreover, spatially resolved zones of active and passive microneedles allow a combinatorial rapid burst response along with slow, sustained release, respectively. Such versatile and effective autonomous dynamic microneedle delivery technology offers considerable promise for a wide range of therapeutic applications, toward a greatly enhanced outcome, convenience, and cost.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lee, H., Choi, T. K., Lee, Y. B., Cho, H. R., Ghaffari, R., Wang, L., Choi, H. J., Chung, T. D., Lu, N., Hyeon, T., et al. (2016) · Nature Nanotechnology · doi:10.1038/nnano.2016.38 · Cited by 1,802
Neutralization of Tumor Acidity Improves Antitumor Responses to Immunotherapy
Pilon-Thomas, S., Kodumudi, K. N., El-Kenawi, A. E., Russell, S., Weber, A. M., Luddy, K., Damaghi, M., Wojtkowiak, J. W., Mulé, J. J., Ibrahim-Hashim, A., et al. (2016) · Cancer Research · doi:10.1158/0008-5472.can-15-1743 · Cited by 593
Cited by
Rational Design of Immunomodulatory Hydrogels for Chronic Wound Healing
Kharaziha, M., Baidya, A., & Annabi, N. (2021) · Advanced Materials · doi:10.1002/adma.202100176 · Cited by 721
Medical Micro/Nanorobots in Precision Medicine
Soto, F., Wang, J., Ahmed, R., & Demirci, U. (2020) · Advanced Science · doi:10.1002/advs.202002203 · Cited by 442
Self-citationWearable Electrochemical Sensors for the Monitoring and Screening of Drugs
Teymourian, H., Parrilla, M., Sempionatto, J. R., Montiel, N. F., Barfidokht, A., Van Echelpoel, R., De Wael, K., & Wang, J. (2020) · ACS Sensors · doi:10.1021/acssensors.0c01318 · Cited by 423
Self-citationPolydopamine Decorated Microneedles with Fe‐MSC‐Derived Nanovesicles Encapsulation for Wound Healing
Ma, W., Zhang, X., Liu, Y., Fan, L., Gan, J., Liu, W., Zhao, Y., & Sun, L. (2022) · Advanced Science · doi:10.1002/advs.202103317 · Cited by 358
Qu, F., Geng, R., Liu, Y., & Zhu, J. (2022) · Theranostics · doi:10.7150/thno.69999 · Cited by 321
Metadata
- Authors
- Lopez‐Ramirez, M. A., Soto, F., Wang, C., Rueda, R., Shukla, S., Silva‐Lopez, C., Kupor, D., McBride, D. A., Pokorski, J. K., Nourhani, A., Steinmetz, N. F., Shah, N. J., & Wang, J.
- Venue
- Advanced Materials
- Publisher
- Wiley
- Published
- 2019-11-04
- Volume
- 32
- Issue
- 1
- Pages
- e1905740-e1905740
- ISSN
- 0935-9648 (ISSN-L)
- 1521-4095
- OpenAlex
- W2987413771
- Cited by
- 275
- References
- 2
- FWCI
- 10.33
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Built‐In Active Microneedle Patch with Enhanced Autonomous Drug Delivery. https://app.cochat.ai/papers/10.1002/adma.201905740
- The paper
- Lopez‐Ramirez, M. A., Soto, F., Wang, C., Rueda, R., Shukla, S., Silva‐Lopez, C., Kupor, D., McBride, D. A., Pokorski, J. K., Nourhani, A., Steinmetz, N. F., Shah, N. J., & Wang, J. (2020). Built‐In Active Microneedle Patch with Enhanced Autonomous Drug Delivery. Advanced Materials. https://doi.org/10.1002/adma.201905740
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.