Cited by 542Polymer Surface Interaction StudiesDendrimers and Hyperbranched PolymersSurgical Sutures and Adhesives

Water-triggered hyperbranched polymer universal adhesives: From strong underwater adhesion to rapid sealing hemostasis

Cui, Chunyan, Fan, Chuanchuan, Wu, Yuanhao, Xiao, Meng, Wu, Tengling, Zhang, Dongfei, Chen, Xinyu, Liu, Bo +3 more·2019·Advanced Materials

Abstract

Despite recent advance in bioinspired adhesives, achieving strong adhesion and sealing hemostasis in aqueous and blood environments is challenging. A hyperbranched polymer (HBP) with a hydrophobic backbone and hydrophilic adhesive catechol side branches is designed and synthesized based on Michael addition reaction of multi-vinyl monomers with dopamine. It is demonstrated that upon contacting water, the hydrophobic chains self-aggregate to form coacervates quickly, displacing water molecules on the adherent surface to trigger increased exposure of catechol groups and thus rapidly strong adhesion to diverse materials from low surface energy to high energy in various environments, such as deionized water, sea water, PBS, and a wide range of pH solutions (pH = 3 to 11) without use of any oxidant. Also, this HBP adhesive (HBPA) exhibits a robust adhesion to fractured bone, precluding the problem of mismatched surface energy and mechanical properties. The HBPA's adhesion is repeatable in a wet condition. Intriguingly, the HBPA is capable of gluing dissimilar materials with distinct properties. Importantly, introducing long alkylamine into this modular hyperbranched architecture contributes to formation of an injectable hemostatic sealant that can rapidly stop visceral bleeding, especially hemorrhage from deep wound.

Integrity signals

Registry

Crossref · 10.1002/adma.201905761

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cited by

Sorted by citations

Authors
Cui, C., Fan, C., Wu, Y., Xiao, M., Wu, T., Zhang, D., Chen, X., Liu, B., Xu, Z., Qu, B., & Liu, W.
Affiliations
Tianjin University (CN)
Corresponding author
Liu, Wenguang
Venue
Advanced Materials
Publisher
Wiley
Published
2019-10-18
Volume
31
Issue
49
Pages
e1905761-e1905761
ISSN
  • 0935-9648 (ISSN-L)
  • 1521-4095
OpenAlex
W2980540973
Cited by
542
References
0
Citations by year
2026: 50 · 2025: 64 · 2024: 93 · 2023: 100 · 2022: 106 · 2021: 93 · 2020: 34 · 2019: 1
FWCI
18.39
Type
journal article
Language
en
Open access
closed
Locations
  • Advanced Materials (publishedVersion)
  • PubMed (publishedVersion)
Funders
National Basic Research Program of China (2016YFC1101301)
Topics
  • Physical Sciences › Materials Science › Surfaces, Coatings and Films › Polymer Surface Interaction Studies
  • Physical Sciences › Materials Science › Polymers and Plastics › Dendrimers and Hyperbranched Polymers
  • Health Sciences › Medicine › Surgery › Surgical Sutures and Adhesives
Keywords
coacervation, Michael addition, dopamine, wet adhesion, hemostatic sealant, alkylamines
MeSH terms
Adhesives, Animals, Biocompatible Materials, Catechols, Hemorrhage, Hemostatics, Polymers, Water, Rats, Sprague-Dawley, Biomimetic Materials, Rats, Hydrophobic and Hydrophilic Interactions

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review