The DOI matches its Crossref record.
Thermosensitive Hydrogel Based on PEO–PPO–PEO Poloxamers for a Controlled In Situ Release of Recombinant Adeno‐Associated Viral Vectors for Effective Gene Therapy of Cartilage Defects
Open accessAbstract
Advanced biomaterial‐guided delivery of gene vectors is an emerging and highly attractive therapeutic solution for targeted articular cartilage repair, allowing for a controlled and minimally invasive delivery of gene vectors in a spatiotemporally precise manner, reducing intra‐articular vector spread and possible loss of the therapeutic gene product. As far as it is known, the very first successful in vivo application of such a biomaterial‐guided delivery of a potent gene vector in an orthotopic large animal model of cartilage damage is reported here. In detail, an injectable and thermosensitive hydrogel based on poly(ethylene oxide) (PEO)–poly(propylene oxide) (PPO)–PEO poloxamers, capable of controlled release of a therapeutic recombinant adeno‐associated virus (rAAV) vector overexpressing the chondrogenic sox9 transcription factor in full‐thickness chondral defects, is applied in a clinically relevant minipig model in vivo. These comprehensive analyses of the entire osteochondral unit with multiple standardized evaluation methods indicate that rAAV‐FLAG‐h sox9/PEO–PPO–PEO hydrogel‐augmented microfracture significantly improves cartilage repair with a collagen fiber orientation more similar to the normal cartilage and protects the subchondral bone plate from early bone loss.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Recent progress in targeted delivery vectors based on biomimetic nanoparticles
Chen, L., Hong, W., Ren, W., Xu, T., Qian, Z., & He, Z. (2021) · Signal Transduction and Targeted Therapy · doi:10.1038/s41392-021-00631-2 · Cited by 374
Recent Advances in 3D Printing of Smart Scaffolds for Bone Tissue Engineering and Regeneration
Yuan, X., Zhu, W., Yang, Z., He, N., Chen, F., Han, X., & Zhou, K. (2024) · Advanced Materials · doi:10.1002/adma.202403641 · Cited by 339
Hu, C., Zhang, F., Long, L., Kong, Q., Luo, R., & Wang, Y. (2020) · Journal of Controlled Release · doi:10.1016/j.jconrel.2020.05.010 · Cited by 290
Lv, Z., Hu, T., Bian, Y., Wang, G., Wu, Z., Li, H., Liu, X., Yang, S., Tan, C., Liang, R., et al. (2023) · Advanced Materials · doi:10.1002/adma.202206545 · Cited by 278
In situ formation of injectable hydrogels for chronic wound healing
Gao, Y., Li, Z., Huang, J., Zhao, M., & Wu, J. (2020) · Journal of Materials Chemistry B · doi:10.1039/d0tb01074j · Cited by 189
Articular cartilage repair biomaterials: strategies and applications
Wang, M., Wu, Y., Li, G., Lin, Q., Zhang, W., Liu, H., & Su, J. (2024) · Materials Today Bio · doi:10.1016/j.mtbio.2024.100948 · Cited by 145
Metadata
- Authors
- Madry, H., Gao, L., Rey‐Rico, A., Venkatesan, J. K., Müller‐Brandt, K., Cai, X., Goebel, L., Schmitt, G., Speicher‐Mentges, S., Zurakowski, D., Menger, M. D., Laschke, M. W., & Cucchiarini, M.
- Venue
- Advanced Materials
- Publisher
- Wiley
- Published
- 2019-11-25
- Volume
- 32
- Issue
- 2
- Pages
- e1906508-e1906508
- ISSN
- 0935-9648 (ISSN-L)
- 1521-4095
- OpenAlex
- W2991591738
- Cited by
- 167
- References
- 0
- FWCI
- 12.45
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.