Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 38 of the 42 references it cites were found in a registry or an index.

Multimode Hydraulically Amplified Electrostatic Actuators for Wearable Haptics

Open access
Leroy, Edouard, Hinchet, Ronan, Shea, Herbert · 2020 · Advanced Materials

Abstract

The sense of touch is underused in today’s virtual reality systems due to lack of wearable, soft, mm‐scale transducers to generate dynamic mechanical stimulus on the skin. Extremely thin actuators combining both high force and large displacement are a long‐standing challenge in soft actuators. Sub‐mm thick flexible hydraulically amplified electrostatic actuators are reported here, capable of both out‐of‐plane and in‐plane motion, providing normal and shear forces to the user’s fingertip, hand, or arm. Each actuator consists of a fluid‐filled cavity whose shell is made of a metalized polyester boundary and a central elastomer region. When a voltage is applied to the annular electrodes, the fluid is rapidly forced into the stretchable region, forming a raised bump. A 6 mm × 6 mm × 0.8 mm actuator weighs 90 mg, and generates forces of over 300 mN, out‐of‐plane displacements of 500 µm (over 60% strain), and lateral motion of 760 µm. Response time is below 5 ms, for a specific power of 100 W kg−1. In user tests, human subjects distinguished normal and different 2‐axis shear forces with over 80% accuracy. A flexible 5 × 5 array is demonstrated, integrated in a haptic sleeve.

Overview

Integrity signals

Registry

Crossref · 10.1002/adma.202002564

Cites

38 of 38 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 42 references

Research works printed but not linked: 5

  1. Jansen Y., 2010, ITS’10, ACM (2010), 11
  2. Agharese N., 2018, 2018 IEEE International Conf. on Robotics and Automation (ICRA), 1
  3. Carpi F., 2011, Electroactive Polymer Actuators and Devices (EAPAD) 2011, 364
  4. Sîrbu I.‐D., 2019, Electroactive Polymer Actuators and Devices (EAPAD) XXI, 109662D
  5. Poulin A., 2015, Electroactive Polymer Actuators and Devices (EAPAD) 2015, 943011

Cited by

See all 295

Metadata

Authors
Leroy, E., Hinchet, R., & Shea, H.
Affiliations
École Polytechnique Fédérale de Lausanne (CH)
Corresponding author
Shea, Herbert
Venue
Advanced Materials
Publisher
Wiley
Published
2020-07-23
Volume
32
Issue
36
Pages
e2002564-e2002564
ISSN
  • 0935-9648 (ISSN-L)
  • 1521-4095
OpenAlex
W3045105376
Cited by
276
References
42
Citations by year
2026: 40 · 2025: 47 · 2024: 60 · 2023: 52 · 2022: 34 · 2021: 36 · 2020: 7
FWCI
10.13
Type
journal article
Language
en
Open access
Locations
  • Advanced Materials (publishedVersion)
  • PubMed (publishedVersion)
  • Infoscience (Ecole Polytechnique Fédérale de Lausanne) (submittedVersion, cc-by-nc-nd)
Funders
Hasler Stiftung
Topics
  • Physical Sciences › Materials Science › Electronic, Optical and Magnetic Materials › Dielectric materials and actuators
  • Life Sciences › Neuroscience › Cognitive Neuroscience › Tactile and Sensory Interactions
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
Keywords
electrostatic actuators, wearable haptics, soft actuators, fluid-filled cavity, elastomers, virtual reality haptics, tactile feedback
MeSH terms
Wearable Electronic Devices, Biomechanical Phenomena, Equipment Design, Fingers, Humans, Static Electricity, Touch Perception

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Multimode Hydraulically Amplified Electrostatic Actuators for Wearable Haptics. https://app.cochat.ai/papers/10.1002/adma.202002564
The paper
Leroy, E., Hinchet, R., & Shea, H. (2020). Multimode Hydraulically Amplified Electrostatic Actuators for Wearable Haptics. Advanced Materials. https://doi.org/10.1002/adma.202002564

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.