Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics
Open accessAbstract
Medical robots are invaluable players in non-pharmaceutical treatment of disabilities. Particularly, using prosthetic and rehabilitation devices with human-machine interfaces can greatly improve the quality of life for impaired patients. In recent years, flexible electronic interfaces and soft robotics have attracted tremendous attention in this field due to their high biocompatibility, functionality, conformability, and low-cost. Flexible human-machine interfaces on soft robotics will make a promising alternative to conventional rigid devices, which can potentially revolutionize the paradigm and future direction of medical robotics in terms of rehabilitation feedback and user experience. In this review, the fundamental components of the materials, structures, and mechanisms in flexible human-machine interfaces are summarized by recent and renowned applications in five primary areas: physical and chemical sensing, physiological recording, information processing and communication, soft robotic actuation, and feedback stimulation. This review further concludes by discussing the outlook and current challenges of these technologies as a human-machine interface in medical robotics.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
231 of 600 cited sources checked · 65 supported · 7 flagged · accuracy not yet measured
- Premisecitation
Some resistive sensors analyze changes in contact resistance, such as the quantum tunneling effect.
“Meanwhile, another resistive sensor may analyze the changes in the contact resistance, like the quantum tunneling effect (Figure 4A).[114,115]”
Quote in the paperNot a substantial claim1 of 2 sources checked- cites [114] source
The Abstract (page unavailable) describes contact-resistance sensing and Fowler–Nordheim quantum tunneling as distinct mechanisms, not tunneling as an example of contact resistance. The Fabrication and properties section (page unavailable) says the particles in its tunneling sensor cannot contact one another during compression. (LLM, conf=0.86)
Checked by a reasoning model — may be wrong.
Experimental — accuracy not yet measured - cites [115] source
- Premisecitation
After preprocessing EMG data, artificial neural networks classified 17 hand gestures from 6 EMG electrodes with 83% accuracy.
“By first preprocessing EMG data, ANNs were shown to classify 17 hand gestures from 6 EMG electrodes with an accuracy of 83%,[446]”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [446] source
The Data processing via ML technology section describes six channels of TENG sensor signals used to classify six gripped objects, not six EMG electrodes used to classify 17 hand gestures. It reports PCA followed by an SVM classifier and 97.1% accuracy, rather than an ANN and 83%. (LLM, conf=0.87)
Checked by a reasoning model — may be wrong.
Experimental — accuracy not yet measured
- Premisecitation
In recent years, flexible implantable stimulators with various mechanisms including electrical, optogenetic, ultrasonic, and magnetic are being developed as non-pharmacological treatment options.
“In recent years, profiting from the academic interest and deep exploration in neuroscience, flexible implantable stimulators with various mechanisms (electrical,[521–523] optogenetic,[524,525] ultrasonic,[526,527] magnetic[528]) are being developed as non-pharmacological treatment options.”
Quote in the paperNot a substantial claim3 of 7 sources checked- cites [521] source
- cites [522] source
The Abstract and Introduction (pages not supplied) describe a flexible, implantable μLED probe developed for optogenetic neural stimulation. The Conclusion says its purpose is to study neural circuits; our copy does not describe the probe as a non-pharmacological treatment option. This citation supports the optogenetic-device example, but not the treatment framing. (LLM, conf=0.84)
Experimental — accuracy not yet measured - cites [523] source
- cites [524] source
- cites [525] source
- cites [526] source
Citation [528] is attached to the magnetic example. The Introduction calls the paper’s transcranial magnetic stimulation technique noninvasive, and Section II (Concept and Design) says its flexible coil conforms to the surface of the head. The paper therefore describes a flexible magnetic stimulator, but not an implantable one. Page numbers were not supplied in our copy. (LLM, conf=0.88)
Checked by a reasoning model — may be wrong.
Experimental — accuracy not yet measured - cites [527] source
- Premisecitation
Subjects wearing a PI/Au-based stimulating and sensing hybrid platform attempted to control a robot hand to grip a bottle both with and without electro-tactile stimulation.
“A representative example is that subjects wearing a PI/Au-based stimulating and sensing hybrid platform attempted to control a robot hand to grip a bottle both with and without electro-tactile stimulation.”
Quote in the paperSubstantial claim1 of 1 sources checked- cites [599] source
The Electrode development section describes a 3D-printed electrode coated with graphene ink, contrary to the claimed PI/Au platform. The Application demonstration section describes electrotactile stimulation and EMG/ECG recording, not subjects controlling a robot hand to grip a bottle with and without stimulation. Page numbers are unavailable in our copy. (LLM, conf=0.83)
Checked by a reasoning model — may be wrong.
Experimental — accuracy not yet measured
- Premisereasoning
Optical stimulators for the spinal cord are generally flexible enough to be wraparound or wire-like.
“Thus, optical stimulators for spinal cord are generally flexible enough to be wraparound or wire-like.[556,569–571]”
Quote in the paperNot a substantial claim4 of 4 sources checked- cites [556] source
The “EMG recordings and light stimulation” section (page not provided) describes delivering light to the exposed spinal cord through a fiber-optic cable, which supports a wire-like means of light delivery. It does not describe a wraparound stimulator or establish that spinal-cord optical stimulators are generally flexible enough to take either form. (LLM, conf=0.84)
Experimental — accuracy not yet measured - cites [569] source
The Results (Design and material properties of the soft neural cuff; page not provided) describe a flexible optical cuff that wraps around a peripheral nerve. The Discussion proposes adapting it into a small flexible probe for the spinal cord, but does not establish that spinal-cord optical stimulators are generally wraparound or wire-like. (LLM, conf=0.86)
Experimental — accuracy not yet measured - cites [570] source
The paper describes a flexible filament implanted in the spinal epidural space, supporting the wire-like example. Its stretchable film appliqué is for a peripheral nerve, not a wraparound spinal-cord stimulator, and this device study does not establish that spinal stimulators are generally made in either form (Competing Financial Interests Statement; page unavailable). (LLM, conf=0.85)
Experimental — accuracy not yet measured - cites [571] source
The Online Methods (Implant construction; page unavailable) describe the spinal stimulator as an LED attached directly to the bottom of a circuit board; the wire extension belongs to the brain and peripheral implants. The Surgical procedures section says the spinal implant was cemented over a hole in the vertebra, rather than wrapped around the cord or implanted as a flexible wire. (LLM, conf=0.80)
Checked by a reasoning model — may be wrong.
Experimental — accuracy not yet measured
- Premisecitation
A pneumatic chamber structural design can achieve a pre-defined actuating motion.
“as the structural design of a pneumatic chamber will achieve the pre-defined actuating motion (Figure 2I and 2J).[64–66]”
Quote in the paperNot a substantial claim2 of 3 sources checked- cites [64] source
- cites [65] source
The Results (Implementation in robotics; page unavailable) show that the authors designed a bimorph actuator whose structure produces bending motion. That supports the general link between structural design and intended motion, but their actuator uses electrically heated composite material, not a pneumatic chamber. (LLM, conf=0.78)
Experimental — accuracy not yet measured - cites [66] source
- Premisecitation
Combining soft robotics with e-skin can provide safe, light, low-complexity actuation without the high cognitive strain of rigid heavy counterparts.
“The combination of soft robotics with e-skin can additionally provide the user with a safe, light, and low complexity mode of actuation without the high cognitive strain associated with its rigid and heavy counterpart.[33–35]”
Quote in the paperSubstantial claim2 of 3 sources checked- cites [33] source
- cites [34] source
In “Simplicity and Lower Cost” and “Other Characteristics: Light Weight,” the paper describes simpler control and lighter soft actuators than hard counterparts. “Biomedical Uses” describes safe interaction with humans. These passages do not establish that combining soft robotics with e-skin reduces users’ cognitive strain. (LLM, conf=0.87)
Experimental — accuracy not yet measured - cites [35] source
The Medical/Wearable Applications section says soft devices are compatible with tissue and contrasts them with rigid devices that can cause damage or discomfort. The Stretchable Electronics section anticipates integration with soft robots, and the paper describes lightweight grippers, but it does not establish that combining soft robotics with e-skin produces light, low-complexity actuation or reduces users’ cognitive strain relative to rigid, heavy devices. (LLM, conf=0.84)
Experimental — accuracy not yet measured
- Premisecitation
Advances in feedback sensors, modern designs, and novel materials have led to broader user acceptance of medical prosthetics.
“The progression of feedback sensors, modern designs, and novel materials similarly generated broader user-acceptance of medical prosthetics.[19,20]”
Quote in the paperNot a substantial claim1 of 2 sources checked- cites [19] source
- cites [20] source
The Restoring Sensation section links lack of sensory feedback to prosthesis rejection and says tactile feedback can increase a user's identification with a prosthesis. The Introduction and Restoring Sensation sections describe advances in design, sensors, and materials, but do not establish that these advances have generated broader user acceptance. (LLM, conf=0.84)
Experimental — accuracy not yet measured
- Premisecitation
When e-skin tactile sensing communicates harmful external stimuli to the user, soft robotics can use flexibility and high degrees of freedom to move away and adapt.
“In particular, when e-skin tactile sensing communicates harmful external stimuli to the user, soft robotics can utilize its flexibility and high degree of freedom to efficiently move away and adapt to the scenario.[19,36]”
Quote in the paperSubstantial claim1 of 2 sources checked- cites [19] source
- cites [36] source
The Introduction and Discussion and Conclusion (page numbers unavailable) link e-skin sensing to safe interaction and say soft, compliant robots need sensory feedback for precise control. They do not say that e-skin communicates harmful stimuli to a user or that a soft robot uses high degrees of freedom to move away from them and adapt. (LLM, conf=0.83)
Experimental — accuracy not yet measured
- Premisecitation
Using the strain signal, the subject successfully controlled a prosthetic to assist walking in real-world environments.
“By utilizing the strain signal, the subject successfully controlled the prosthetic to assist walking in real-world environments (Figure 6B).[192]”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [192] source
The Results section reports that a strain-sensor-integrated e-skin demonstrated prosthesis walking control for assistive walking in real-world environments. However, Materials and Methods specifies that a human operator, prompted by the transmitted strain signal, sent the command that triggered each swing step; it does not show the subject directly controlling the prosthesis. (LLM, conf=0.87)
Experimental — accuracy not yet measured
- Premisecitation
Bulky piezoresistive e-skins rely primarily on pressure-induced changes in the number of conductive pathways or in the shape of the sensing material.
“Bulky piezoresistive e-skins, like sponge-based sensors, rely primarily on pressure-induced changes in the number of conductive pathways[112] or in the shape of the sensing material.[113]”
Quote in the paperNot a substantial claim2 of 2 sources checked- cites [112] source
- cites [113] source
The Introduction explains that pressure deforms the sensor’s microchannels, changing their cross-sectional area and electrical resistance. This supports the shape-change mechanism associated with citation [113], but the paper describes a flexible microfluidic sensor, not bulky piezoresistive e-skins generally. (LLM, conf=0.84)
Experimental — accuracy not yet measured
- Premisecitation
Resistive, capacitive, and optical pressure-sensing mechanisms can also be used for flexible strain sensors.
“The mechanisms of pressure sensors mentioned above, like resistive, capacitive, and optical, etc.,[172] can also be applied to flexible strain sensors.”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [172] source
The Results (Fig. 4) demonstrate an optical flexible sensor that detects substrate deformation and external force through changes in laser output. The paper does not establish that resistive or capacitive pressure-sensing mechanisms can also be used for flexible strain sensors. (LLM, conf=0.88)
Experimental — accuracy not yet measured
- Premisecitation
Capacitive integration uses pressure-sensitive capacitors directly as gate capacitors, translating capacitance change into drain current variation in FET-based devices.
“As shown in Figure 4I, capacitive integration uses primarily pressure-sensitive capacitors directly as gate capacitors, where the change in capacitance is translated into a variation in drain current in the field-effect transistor (FET)-based device.[102,130–132]”
Quote in the paperNot a substantial claim3 of 4 sources checked - Premisecitation
Flexible waveguides and magnetic materials have been investigated for wearable strain sensing.
“Similar to the mechanism behind pressure sensing, flexible waveguides[136,153] and magnetic materials[187,188] have also been investigated for wearable strain sensing applications.”
Quote in the paperNot a substantial claim1 of 4 sources checked - Premisecitation
Resistive pressure sensing has been extensively applied because of its simple mechanism and convenient data collection.
“Due to its simple mechanism and convenient data collection strategy, resistive pressure sensing has been extensively applied using various recording mechanisms.[111]”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [111] source
- Premisecitation
A biofuel-powered strain sensor integrated on a human elbow captured strain signals.
“As shown in Figure 6A, a biofuel powered strain sensor was integrated onto a human elbow to capture strain signals.”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [192] source
- Premisecitation
Some microscopic strain-sensing mechanisms-misplace, disconnection, and crack propagation-are not found in pressure sensing.
“It is worth noting that some microscopic mechanisms in strain sensing, like misplace,[173,174] disconnection,[175] and crack propagation[168,176] are not available in pressure sensing.”
Quote in the paperNot a substantial claim2 of 5 sources checked- cites [173] source
The “In plane mechanical fracture modulation enabled by 2D interlayers” section reports crack propagation during bending and its effects on electrical conductance. It does not establish that crack propagation is a strain-sensing mechanism unavailable in pressure sensing. The citations for misplace and disconnection attach to other sources, so those examples are not assessed here. (LLM, conf=0.85)
Experimental — accuracy not yet measured - cites [174] source
The Results describe resistance changes in the MXene sensor under pressure, but do not compare strain-sensing and pressure-sensing mechanisms. A reference lists a microcrack-designed pressure sensor, but our copy does not say whether crack propagation is its sensing mechanism. Searches for misplace, disconnection, and crack propagation did not establish the claimed exclusion. (LLM, conf=0.70)
Experimental — accuracy not yet measured - cites [175] source
- cites [168] source
- cites [176] source
- Premisecitation
Thin metal films such as Au and Pt are widely used in flexible temperature detectors because of their good linearity and established microfabrication.
“Thin metal films, like Au,[210] Pt[211] are widely employed in constructing flexible temperature detectors due to their good linearity and proven success in their microfabrication technologies.”
Quote in the paperNot a substantial claim2 of 2 sources checked- cites [210] source
The paper describes flexible temperature sensors made from thin Au traces, and Methods > Fabrication of TCR devices details their microfabrication (page unavailable). It does not establish that Au is widely employed or attribute its use to good linearity. Pt is attached to a different citation in the citing sentence and is not judged here. (LLM, conf=0.82)
Experimental — accuracy not yet measured - cites [211] source
- Premisecitation
Integrating temperature and pressure sensors into one substrate would provide higher spatial resolution.
“Integrating the two sensors into one substrate would provide a higher spatial resolution.[104,105]”
Quote in the paperNot a substantial claim2 of 2 sources checked- cites [104] source
- cites [105] source
The Results section describes pressure and temperature sensors integrated with a fingerprint sensor array. The Discussion reports high resolution for the fingerprint array, but does not say that integrating the pressure and temperature sensors increases spatial resolution. Page numbers were not available in our copy. (LLM, conf=0.84)
Experimental — accuracy not yet measured
- Premisecitation
An intrinsically stretchable rubbery electronic can be used to fabricate thermistors.
“Figure 7C shows an intrinsically stretchable rubbery electronic, which can be used to fabricate thermistors.[222]”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [222] source
- Premisecitation
An artificial fingertip with e-skin acquired information about thermal properties and surface texture of different materials.
“One such example used an artificial fingertip with e-skin to acquire information about the thermal properties and surface texture of different materials.”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [224] source
- Premisecitation
Using machine learning, combined vibrational and thermal information identified the group and type of materials.
“Using machine learning, the combination of vibrational and thermal information was used to identify the group (e.g. wood, metal, plastic) and type (e.g. aluminum, copper, pine, etc.) of the material.[224]”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [224] source
- Premisecitation
NTC thermistors have a clear advantage over other temperature sensors because they have a simpler structure while providing equivalently high temperature sensitivity.
“The negative temperature coefficient (NTC) thermistor has a clear advantage over other temperature sensors in that it exhibits a much simpler structure while presenting equivalently high temperature sensitivity.[215]”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [215] source
The passage labeled Abstract says NTC thermistors have a simpler structure and equivalently high sensitivity compared with IC temperature sensors. The citing sentence broadens that comparison to other temperature sensors generally, which the passage does not establish. (LLM, conf=0.88)
Experimental — accuracy not yet measured
- Premisecitation
The most conventional multisensory model places temperature and pressure sensors on different parts of a prosthesis.
“The most conventional multisensory model is for temperature and pressure sensors to be placed on different parts of a prosthesis (Figure 7C and 7D).[222]”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [222] source
The section “Intrinsically stretchable rubbery sensors for robotic skins” (p. 5) describes temperature and pressure sensors mounted on a robotic hand. It says both were placed on the finger phalanges rather than the joints; it does not say they were placed on different parts from each other, describe a prosthesis, or characterize this arrangement as the most conventional model. (LLM, conf=0.86)
Experimental — accuracy not yet measured
- Premisecitation
Resistive metallic temperature sensors and thermistors are the most commonly used sensors in flexible thermal electronics.
“Resistive metallic temperature sensors[207] and thermistors[208] are the most commonly used sensors in flexible thermal electronics.”
Quote in the paperNot a substantial claim2 of 2 sources checked- cites [207] source
The Design and fabrication section identifies gold serpentine resistors as temperature sensors, and Spatiotemporal cardiac measurements and stimulation explains that their resistance changes with temperature. This supports the cited example of a metallic resistive temperature sensor, but the paper does not establish that such sensors are among the most commonly used in flexible thermal electronics. (LLM, conf=0.84)
Experimental — accuracy not yet measured - cites [208] source
The Introduction (page unavailable) describes a flexible thermal sensor using a ZnO-based thermistor, supporting the citation as an example of that sensor type. The paper does not establish that thermistors are among the most commonly used sensors in flexible thermal electronics. (LLM, conf=0.85)
Experimental — accuracy not yet measured
- Premisecitation
A dual-parameter device using independent thermoelectric and piezoresistive effects can simultaneously transduce temperature and pressure stimuli into separate electrical signals.
“In Figure 7E, by taking advantage of independent thermoelectric and piezoresistive effects, a dual parameter device can simultaneously transduces temperature and pressure stimuli into separate electrical signals.[107]”
Quote in the paperSubstantial claim1 of 1 sources checked- cites [107] source
- Premisecitation
Conventional commercially available integrated-circuit components (more than ten chips) can be applied on an FPCB for data processing and transmission.
“Conventional commercially available integrated-circuit components (more than ten chips) can be applied on a FPCB to serve as data processing and transmission.[83]”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [83] source
- Premisecitation
Novel dual-parameter sensors that transduce different stimuli into separate signals can minimize signal interference, allowing temperature and pressure detection at a single point without decoupling analysis.
“The development of novel dual-parameter sensors that transduce different stimuli into separate signals can minimize signal interference, allowing the detection of both temperature and pressure at a single point without decoupling analysis.[107,228,229]”
Quote in the paperSubstantial claim2 of 3 sources checked - Premisecitation
A fully integrated wearable sensor array for multiplexed in-situ perspiration analysis measured sodium, potassium, lactate, and glucose in sweat simultaneously by electrochemical methods.
“Recently, a fully integrated wearable sensor array for multiplexed in-situ perspiration analysis was reported, where the sodium, potassium, lactate, and glucose content of sweat can be measured simultaneously by electrochemical methods.”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [83] source
- Premisecitation
Other flexible health monitoring mechanisms like optoelectronic and ultrasound devices can be applied to heartbeat, pulse oximetry, blood pressure, and other on-body measurements.
“Other mechanisms of flexible health monitoring in rehabilitation, like optoelectronic[263,264] and ultrasound[265,266] devices, can also be applied to heartbeat, pulse oximetry, blood pressure, and other on-body measurements.”
Quote in the paperNot a substantial claim3 of 4 sources checked- cites [263] source
The Abstract describes an ultraflexible optical sensor for photoplethysmogram monitoring and identifies pulse oximetry as an application of flexible optical sensors. The Fig. 4 caption reports blood-pulse detection at 77 beats per minute. Our copy does not establish blood-pressure measurement by this device; the ultrasound citations are separate from the citations attached to optoelectronic devices. (LLM, conf=0.84)
Experimental — accuracy not yet measured - cites [264] source
- cites [265] source
- cites [266] source
The Abstract describes a wearable, skin-conformal ultrasonic device that continuously monitors blood-pressure waveforms. The Results (‘Dynamic hemodynamics monitoring’) also report heart-rate measurements. Our copy does not show this ultrasonic device measuring pulse oximetry, so it supports only part of the measurement list attributed to it. (LLM, conf=0.84)
Experimental — accuracy not yet measured
- Premisecitation
Recent advancements in soft and nanomaterials have opened more options for flexible recording electrodes, such as conductive polymers and nanomaterial composites.
“Recent advancements in soft and nanomaterials have opened up more options for flexible recording electrodes, like conductive polymers (e.g., PEDOT)[302,312] and nanomaterial composites (metal-based, CNT, graphene)[313–317].”
Quote in the paperNot a substantial claim5 of 7 sources checked- cites [302] source
The paper describes flexible PEDOT:PSS/glycerol electrodes and says they are promising for neurophysiological recording (Abstract, page unavailable). It does not establish the claim about metal-based, CNT, or graphene nanomaterial composites, and recording is presented as a prospective use rather than a demonstrated function. (LLM, conf=0.85)
Experimental — accuracy not yet measured - cites [312] sourceExperimental — accuracy not yet measured
- cites [313] source
- cites [314] source
The Discussion and Conclusion describe a stretchable gold-nanowire/PDMS composite cuff electrode, supporting the metal-based nanomaterial example. But the paper develops and tests that electrode for peripheral nerve stimulation, not recording. Its Introduction mentions recording with other flexible electrodes, which does not establish recording use for this device. (LLM, conf=0.86)
Experimental — accuracy not yet measured - cites [315] source
- cites [316] sourceExperimental — accuracy not yet measured
- cites [317] sourceExperimental — accuracy not yet measured
- Premisecitation
Recent advances in wireless charging and self-powered technologies have been established to limit the number of replacement surgeries.
“Recent advances in wireless charging and self-powered technologies have been established to limit the number of times a user must undergo replacement surgery.[326]”
Quote in the paperSubstantial claim1 of 1 sources checked- cites [326] source
Section 5, “Wearable Self-Charging Power Units” (page unavailable), says self-charging units address the inconvenience of frequently recharging or replacing wearable power supplies. Section 6.2 describes wireless power delivery for a battery-free wearable sensor. Neither passage says these technologies reduce replacement surgeries; the paper focuses on wearable, non-invasive devices. (LLM, conf=0.85)
Experimental — accuracy not yet measured
- Premisecitation
High spatial and temporal resolution of ECoG and LFPs can provide finer and more accurate control signals for prostheses because neuronal areas can be recorded independently at higher density.
“Moreover, the high spatial and temporal resolution of ECoG and LFPs can provide finer and more accurate control signals for prostheses as the neuronal areas can be recorded independently at a higher density.[333,334]”
Quote in the paperSubstantial claim2 of 2 sources checked- cites [333] source
The Introduction and Discussion describe high-density ECoG recordings from sensorimotor areas that enabled online control of individual prosthetic fingers; Methods §2.1 specifies the dense electrode array. The paper does not establish the claim about LFPs or explicitly show that high spatial and temporal resolution makes control signals more accurate. Page numbers are not available in our copy. (LLM, conf=0.84)
Experimental — accuracy not yet measured - cites [334] source
The Abstract says ECoG has greater spatial specificity and bandwidth than EEG, and IV. Future Directions suggests higher-resolution ECoG arrays may better localize cortex involved in hand and finger movements. But II. Methods only defines LFPs; the paper does not extend the resolution or prosthetic-control claim to LFPs, nor does it say independently recording areas at higher density yields finer, more accurate control signals. Page numbers are unavailable in our copy. (LLM, conf=0.84)
Experimental — accuracy not yet measured
- Premisecitation
Studies on different interface locations and probing devices have established the foundation of user-communication with prosthetics.
“Thus, the vast number of studies on different interface locations and various probing devices to record electrophysiological signals have established the foundation of user-communication with prosthetics.[24,286,287]”
Quote in the paperNot a substantial claim2 of 3 sources checked - Premisecitation
Penetrating electrodes are mostly rigid enough to maintain structural integrity in muscle.
“The penetrating electrodes are mostly rigid enough to maintain their structural integrity in the muscle.[367,368]”
Quote in the paperNot a substantial claim2 of 2 sources checked- cites [367] source
The Materials and Methods section (IMES technical description; page unavailable) describes electrodes on a ceramic-packaged implant, and the Results (Animal experiments; page unavailable) report that implanted devices operated without problems and did not migrate in chronic animal studies. Those observations support stability of this particular implant in muscle, but the paper does not establish that penetrating electrodes are mostly rigid or that rigidity maintains their structural integrity. (LLM, conf=0.78)
Experimental — accuracy not yet measured - cites [368] source
The Introduction describes stiff electrodes, and the Discussion identifies several more rigid electrode arrays. Neither section says that penetrating electrodes are mostly rigid or that their rigidity maintains structural integrity in muscle. (LLM, conf=0.76)
Experimental — accuracy not yet measured
- Premisecitation
Mesh structures are distinguished for both inserted and superficial neural implants owing to their stretchability and adaptability.
“As another representative type of flexible structures, the mesh structure also distinguishes it for both inserted and superficial neural implants owing to its stretchability and adaptability.[301,348–350]”
Quote in the paperNot a substantial claim1 of 4 sources checked- cites [301] source
- cites [348] source
The paper’s Abstract (page unavailable) says mesh designs improve conformal coverage, and it describes mesh electrode arrays placed on the exposed brain. It does not establish their use as inserted, penetrating neural implants or attribute the improvement specifically to stretchability. (LLM, conf=0.86)
Experimental — accuracy not yet measured - cites [349] source
- cites [350] source
- Premisecitation
Spiral cuff electrodes can circumscribe the nerve, which limits variation in nerve diameter unless they are stretchable.
“In this type, spiral means that the ability to circumscribe the nerve, which somewhat limits the variation in nerve diameter (nerve growth), unless the electrodes are stretchable spiral cuffs.[302,361]”
Quote in the paperNot a substantial claim2 of 2 sources checked- cites [302] source
The paper reports that a cuff electrode’s inner diameter was outgrown by a rat sciatic nerve, constraining and deforming it (Abstract; page unavailable). This supports the concern about nerve growth, but the passages do not identify the cuff as spiral or establish that making a spiral cuff stretchable would remove that limitation; the paper also reports constraint from an elastic cuff substrate. (LLM, conf=0.82)
Experimental — accuracy not yet measured - cites [361] source
The Results and discussion and Mechanical cycling passages describe commercially available nerve cuffs connected to stretchable LCE cables. They do not address spiral cuffs, whether they circumscribe a nerve, or whether cuff stretchability accommodates changes in nerve diameter (searched: spiral cuff, circumscribe, nerve growth, diameter). (LLM, conf=0.76)
Experimental — accuracy not yet measured
- Premisecitation
Any delay beyond 300 milliseconds results in a user-perceived lag.
“Any delay beyond 300 milliseconds will further result in a user-perceived lag.[432]”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [432] source
Section 6.3 (p. 23) discusses microsecond delays in vacuum-tube circuits, not a threshold for user-perceived lag. A search for 300 milliseconds and human perception found no passage in our copy supporting the claimed threshold. (LLM, conf=0.78)
Experimental — accuracy not yet measured
- Premisecitation
A 17-mesh-electrode epidermal sensing array is placed on residual limbs to capture EMG for prosthetics.
“As demonstrated in Figure 9D, a high-density epidermal sensing array consisting of 17 mesh electrodes is integrated on the residual limbs to record EMG signals for prosthetic applications.”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [388] source
The Results section on speech recognition reports EMG recorded from the neck using an epidermal device. The device-design section describes a pair of electrophysiological electrodes, not a 17-mesh-electrode array; our copy does not report placing such an array on residual limbs for prosthetic applications. Page numbers are unavailable in our copy. (LLM, conf=0.87)
Experimental — accuracy not yet measured
- Premisecitation
Surface EMG is in principle a low-cost and specific way of detecting what the patient wants the prosthetic to do.
“Surface EMG is therefore, in principle, a low-cost and specific way of detecting what the patient wants the prosthetic to do.[400,401]”
Quote in the paperNot a substantial claim2 of 2 sources checked- cites [400] source
The Introduction mentions EMG as a technique used with patients who have neural-system disorders, but does not describe surface EMG as a way to detect intended prosthetic actions. The Discussion’s lower-cost finding concerns the paper’s EOG graphene sensors, not EMG. Searches for surface EMG, prosthetic control, patient intention, and cost found no passage establishing the claim. (LLM, conf=0.75)
Experimental — accuracy not yet measured - cites [401] source
The Methods section (page unavailable) says EMG was recorded to rule out overt movements during motor imagery, not to detect intended prosthetic actions. The paper describes EEG and EOG as the signals used to control the hand exoskeleton. Searches for EMG-based intent detection and cost found no passage addressing whether surface EMG is a low-cost, specific way to detect what a patient wants a prosthetic to do. (LLM, conf=0.75)
Experimental — accuracy not yet measured
- The authors state this as an assumption: The user's intentions can be extracted from the activation of the remnant muscles.
- Premisecitation
Versatile epidermal electrodes with high performance can universally measure EEG, EMG, EOG, and ECG by placing electrodes on different skin areas.
“Researchers have developed various versatile epidermal electrodes with high performance that can universally measure EEG, EMG, EOG, and ECG through placing electrodes on different areas of the skin.[25,414]”
Quote in the paperNot a substantial claim2 of 2 sources checked- cites [25] source
Section 4.2 (page not provided) describes skin-contacting electrodes used to monitor ECG, EMG, and EEG, with placement depending on the target body part. It does not mention EOG or establish that the same versatile, high-performance epidermal electrodes can universally measure all four signals simply by changing placement. (LLM, conf=0.85)
Experimental — accuracy not yet measured - cites [414] source
The “Sensor designs, system configurations, and wireless, battery-free modes of operation” section (Fig. 1A; page not provided) describes skin-interfaced electrodes recording ECG on the chest. The paper describes a separate foot-mounted optical sensor for PPG, but the passages do not support measuring EEG, EMG, or EOG by moving the electrodes to other skin areas. (LLM, conf=0.88)
Experimental — accuracy not yet measured
- Premisecitation
Ultrathin film electrode arrays are a promising and widely adopted option for electrocorticography electrodes on the cortex surface, owing to high recording density in a non-penetrating fashion.
“Referring to another brain (ECoG) recording, ultrathin film electrode arrays are a promising and widely adopted option for electrodes used on the surface of the cortex, owing to its high recording density in a non-penetrating fashion.[296,343–346]”
Quote in the paperNot a substantial claim5 of 5 sources checked- cites [296] source
The Abstract (page not provided) describes flexible, non-penetrating subdural arrays as capable of high-resolution ECoG recording, and the fabrication section describes the paper’s ultrathin, high-resolution device. It does not establish that ultrathin, high-density arrays were widely adopted; the Abstract instead says clinically used subdural electrodes were larger and more widely spaced. (LLM, conf=0.86)
Experimental — accuracy not yet measured - cites [343] source
The Results describe the NeuroGrid as a 4-μm-thin array with densely spaced electrodes, and the Abstract reports recording from the cortical surface without penetrating it. The Discussion presents it as a promising approach for surface recording. The paper calls the NeuroGrid novel, however, and does not establish that ultrathin film arrays were widely adopted. Page numbers are unavailable in our copy. (LLM, conf=0.87)
Experimental — accuracy not yet measured - cites [344] source
The Introduction describes ultrathin, flexible surface μECoG arrays as capable of dense neural sampling with little tissue injury, supporting their promise as non-penetrating cortical electrodes. The Results report a high-density, 1008-electrode array. Neither passage establishes that such arrays are widely adopted. (LLM, conf=0.84)
Experimental — accuracy not yet measured - cites [345] source
The paper’s Abstract describes a high-density, stretchable grid that records from the cortical surface in rats; its fabrication description gives a thickness of approximately 80 μm. This supports the surface-recording and high-density aspects, but the paper does not establish that ultrathin film arrays are widely adopted for ECoG. (LLM, conf=0.86)
Experimental — accuracy not yet measured - cites [346] source
The Results describe a 4-by-4 electrode array on a thin PET film, and the imaging section reports placing it on the cortical surface to record electrical activity without penetrating the cortex (pages not supplied). The Discussion calls high-density arrays a future fabrication possibility, rather than establishing that ultrathin-film ECoG arrays are already widely adopted or that high recording density explains their adoption. (LLM, conf=0.86)
Experimental — accuracy not yet measured
- Premisecitation
The multiplexed neural interface arrays implanted over sensorimotor cortices in monkeys presented stable long-term recording.
“To verify the feasibility of the device, the arrays were implanted over sensorimotor cortices in monkeys, which presents a stable long-term recording. (Figure 8C).[347]”
Quote in the paperSubstantial claim1 of 1 sources checked- cites [347] source
The “Interfaces with the Peripheral Nerve” section discusses recording instability in peripheral-nerve electrode arrays, not multiplexed arrays implanted over monkey sensorimotor cortices. Searches for monkey sensorimotor implants and stable long-term recording found no passage addressing the claimed experiment. (LLM, conf=0.76)
Experimental — accuracy not yet measured
- Premisecitation
Flexible cuff electrodes, both spiral and helical shaped, are the most common peripheral nerve electrodes.
“For these cable-like peripheral nerves, the flexible cuff electrodes (both spiral[356,357] and helical[358,359] shaped) are the most common ones that must be mentioned.[360]”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [360] source
The “Extra-neural interfaces” section identifies helical and spiral cuff designs and says cuff interfaces are the most common *among extra-fascicular types*. It does not establish that they are the most common peripheral-nerve electrodes overall or explicitly describe these designs as flexible. (LLM, conf=0.86)
Experimental — accuracy not yet measured
- Premisecitation
Various soft mechanical and thermal actuators have been extensively adopted as artificial muscles and heat sources in prosthetic actuation.
“Currently, various soft mechanical[76,460] and thermal actuators[106,461] have been extensively adopted as artificial muscles and heat sources in prosthetic actuation.”
Quote in the paperNot a substantial claim2 of 4 sources checked- cites [76] source
- cites [460] source
- cites [106] source
The Results describe electroresistive thermal actuators that heat a prosthetic skin layer, and the section on SiNR mechanical sensors reports that the heater can maintain body temperature. This supports the thermal-actuator example, but this paper does not establish that various actuators have been extensively adopted across prosthetic applications. (LLM, conf=0.85)
Experimental — accuracy not yet measured - cites [461] source
- Premisecitation
Prosthetic actuation has repeatedly been shown to enhance rehabilitation recovery through assisted motion actuation and heat therapy after paralysis, muscle injury, or loss of limb.
“Despite these issues, prosthetic actuation has repeatedly been shown to enhance rehabilitation recovery through assisted motion actuation[458] and heat therapy[203] after paralysis, muscle injury, or loss of limb.[459]”
Quote in the paperNot a substantial claim1 of 3 sources checked- cites [458] source
- cites [203] source
- cites [459] source
The citation is attached to “heat therapy.” Section 2.3 describes a heated glove providing thermal feedback and a potential surgical ablation tool, not heat therapy for rehabilitation. The Discussion likewise reports no recovery outcomes; searches for rehabilitation and heat therapy found no supporting passage in our copy. (LLM, conf=0.76)
Experimental — accuracy not yet measured
- Premisecitation
In medical robotics, convolutional neural networks can be applied to textile-based tactile sensors to classify human poses, motions, and other user interactions.
“For medical robotics, CNNs can be applied to textile-based tactile sensors to classify human poses, motions, and other user interactions (Figure 11A–11C).[160,444]”
Quote in the paperNot a substantial claim1 of 2 sources checked- cites [160] source
- cites [444] source
The Conclusions (page not provided) report classifying hand movements for a myoelectric prosthetic hand, supporting the medical-robotics movement-classification aspect. Section 4.2 (page not provided) specifies a multilayer perceptron, while the Conclusions specify EMG sensors; the paper does not support the claim about CNNs, textile-based tactile sensors, or classification of poses and other user interactions. (LLM, conf=0.85)
Experimental — accuracy not yet measured
- Premisecitation
The human hand can achieve various dexterous gestures with almost 23 degrees of freedom.
“The human hand can achieve various dexterous gestures with almost 23 degrees of freedoms (DOFs).[454]”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [454] source
The Background discusses prosthetic devices with 10 and 16 degrees of freedom, and Methods > Data and training describes 3- and 4-DoF prosthetic controllers; neither gives a degree-of-freedom count for the human hand. Searches for “23-DoF” and human-hand degrees of freedom found no passage supporting the claimed figure or its link to dexterous gestures. Page numbers were not available in our copy. (LLM, conf=0.73)
Experimental — accuracy not yet measured
- Premisecitation
Artificial sensory neurons have been used to detect tactile, noxious, and mechanical stimuli.
“Another promising neuromorphic design for communication is artificial sensory neurons, which have already been applied to measure tactile, noxious, and mechanical stimuli.[440]”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [440] source
The paper’s Abstract describes an artificial sensory neuron that detects touch patterns through a pressure sensor, supporting tactile and mechanical stimuli. It does not report detecting noxious stimuli; its reference to pain being alleviated by gentle strokes is an analogy for how two tactile inputs interact, not a noxious-stimulus measurement. (LLM, conf=0.88)
Experimental — accuracy not yet measured
- Premisecitation
After touching a baby doll with a robotic hand with the e-skin, heat transfer to the doll was similar to that of a human natural hand.
“After touching a baby doll using a robotic hand with the e-skin, the heat transfer to the baby doll is then captured with an infrared camera, which is similar to that of human natural hand (Figure 14C).[106]”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [106] source
The SiNR mechanical sensors section says the artificial skin was heated to about 36.5 °C to mimic body temperature and that heat transfer to the baby doll was captured with an IR camera. The Figure 5 caption says heat remained after the prosthetic hand was removed. Our copy does not report a comparison of that heat transfer with a natural human hand. (LLM, conf=0.84)
Experimental — accuracy not yet measured
- Premisecitation
Some subjects wearing prostheses with sensory feedback reported that stimulation eliminates phantom pains in the artificial limbs.
“Moreover, some subjects wearing prostheses with sensory feedback reported that stimulation eliminates phantom pains in the artificial limbs.[157,519]”
Quote in the paperNot a substantial claim1 of 2 sources checked - Premisecitation
Flexible heaters, such as a graphene-AgNP-based heater, can be combined with traditional Chinese medicine to treat arthritis.
“Flexible heaters, like a graphene-AgNP-based heater, can also be combined with traditional Chinese medicine to treat arthritis.[514]”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [514] source
The Results (Fabrication of MOSD) and Methods (MOSD fabrication and characterization; page numbers unavailable) describe a polyurethane shape-memory device with mini-LEDs for nerve stimulation. Searches for graphene-AgNP heaters, traditional Chinese medicine, and arthritis found no passage addressing their combination or its use to treat arthritis. (LLM, conf=0.76)
Experimental — accuracy not yet measured
- Premisecitation
Various soft conductive materials such as thin metal, conductive polymers, and nanomaterials can be thermally actuated in the form of resistors.
“Various soft conductive materials such as thin metal,[106] conductive polymers,[508] nanomaterials,[509] etc. can be thermally actuated in the form of resistors.”
Quote in the paperNot a substantial claim2 of 3 sources checked - Premisecitation
These flexible stimulators function by releasing electrical and optical signals into the brain, spinal cord, and periphery nerves to achieve neural modulation for sensory perception and motor rehabilitation.
“These flexible stimulators function by releasing (electrical and optical) signals into the brain,[272] spinal cord,[522] and periphery nerves[529] to achieve neural modulation for associated sensory perception and motor rehabilitation.”
Quote in the paperNot a substantial claim2 of 3 sources checked- cites [272] source
The section on eliciting somatosensory percepts through cortical stimulation describes electrical stimulation of the brain to evoke sensations and discusses optogenetic stimulation as a possible approach. It does not establish that flexible stimulators deliver both electrical and optical signals to the brain for sensory perception and motor rehabilitation; the optical approach is presented as prospective. In the printed sentence, this citation is attached to the brain, not the spinal-cord or peripheral-nerve claims. (LLM, conf=0.84)
Experimental — accuracy not yet measured - cites [522] source
The Device Architecture and Results sections describe flexible probes that deliver light to brain tissue and evoke neuronal activity in mouse brain slices. The paper describes electrical recording, not delivery of electrical stimulation, and does not establish sensory-perception or motor-rehabilitation outcomes. The spinal-cord and peripheral-nerve portions of the citing sentence have separate citations and are not judged here. (LLM, conf=0.88)
Experimental — accuracy not yet measured - cites [529] source
- Premisecitation
Flexible deep brain needles or wires are the most widely adopted carrier for optogenetic localization of cellular-scale stimulation in the brain.
“For instance, flexible deep brain needles or wires offers the most widely adopted carrier for optogenetic localization of cellular-scale stimulation in brain.[342,563–568]”
Quote in the paperNot a substantial claim3 of 7 sources checked- cites [342] source
- cites [563] source
The paper describes flexible, cellular-scale optoelectronic devices inserted into deep brain tissue using releasable needles for localized optogenetic stimulation (Abstract; page not provided). It does not say that flexible needles or wires are the most widely adopted carrier; the needles described are used for insertion, while the devices deliver the light. (LLM, conf=0.82)
Experimental — accuracy not yet measured - cites [564] source
The Main Text describes flexible implanted probes that control the spatial location of optogenetic stimulation. It does not say that flexible deep-brain needles or wires are the most widely adopted carrier; the Introduction instead calls tethered optical fibers the simplest and most common method. No page numbers are available in our copy. (LLM, conf=0.85)
Experimental — accuracy not yet measured - cites [565] source
- cites [566] source
The Introduction (page unavailable) says that skull-anchored optic fibers or head stages deliver light for brain optogenetics. It does not establish that flexible deep-brain needles or wires are the most widely adopted carriers, or that they provide cellular-scale localization; the device studied here targets the spinal cord. (LLM, conf=0.78)
Experimental — accuracy not yet measured - cites [567] source
- cites [568] source
- Premisecitation
Nanomaterials and conductive polymers used in implantable stimulation electrodes have higher charge injection capacity (1-15 mC cm−2) than conventional materials such as Pt (0.05-0.15 mC cm−2) and TiN (0.9 mC cm−2).
“In the recent decade, various nanomaterials[301,345,534,535] and conductive polymers[536–538] have also made their way into implantable stimulation electrodes, which have higher charge injection capacity (1~15 mC cm−2) compared to conventional materials (Pt 0.05~0.15 mC cm−2, TiN 0.9 mC cm−2).[39]”
Quote in the paperSubstantial claim2 of 8 sources checked- cites [39] source
- cites [301] source
- cites [345] source
The electrode-characterization passage (labeled Abstract; page unavailable) reports ≈2.7 mC cm−2 as areal capacitance and describes stability during electrical stimulation, not charge injection capacity. Our copy does not give the claimed 1–15 mC cm−2 range or the Pt and TiN comparison values; searches for charge injection capacity and those materials found no supporting passage. (LLM, conf=0.76)
Experimental — accuracy not yet measured - cites [534] source
- cites [535] source
The charge-injection passage (labeled Abstract in our copy; page unavailable) reports 3.9 mC cm−2 for a conducting-polymer electrode and says it outperformed many common electrode materials. It does not give the claimed Pt range of 0.05–0.15 mC cm−2 or TiN value of 0.9 mC cm−2, or establish the 1–15 mC cm−2 range for nanomaterials and conductive polymers generally. (LLM, conf=0.88)
Experimental — accuracy not yet measured - cites [536] source
- cites [537] source
- cites [538] source
- Premisecitation
Most peripheral nerve neural interfaces can be made flexible to improve mechanical compliance with nerve morphology and biocompatibility.
“Most of these neural interfaces can be somehow flexible to improve mechanical compliance for adapting to the morphology of the peripheral nerve and improving biocompatibility.”
Quote in the paperNot a substantial claim1 of 4 sources checked- cites [357] source
The Abstract (page not specified) says soft, stretchable materials can better match nerve tissue mechanically, and that mechanical adaptability can reduce compression-induced immune responses. It does not establish that most peripheral-nerve interfaces are flexible or can be made flexible. (LLM, conf=0.84)
Experimental — accuracy not yet measured - cites [455] source
- cites [550] source
- cites [551] source
- Premisecitation
Faradic electrodes based on iridium oxides (IrOx) tend to have higher charge capacity than titanium-derived electrodes because of their excellent electrochemical properties.
“Faradic electrodes based on oxides of iridium (IrOx) tend to have a higher charge capacity compared to titanium-derived electrodes due to their excellent electrochemical properties.[532,533]”
Quote in the paperNot a substantial claim1 of 2 sources checked- cites [532] source
- cites [533] source
The Discussion (page unavailable) compares the stimulation charge capacity of CNT yarn electrodes with platinum-iridium wires. Searches for iridium oxide (IrOx), titanium-derived electrodes, and their electrochemical properties found no passage comparing the materials named in the claim. (LLM, conf=0.76)
Experimental — accuracy not yet measured
- Premisecitation
Optogenetic stimulation does not cause muscle fatigue as prolonged and irregular electrical stimulation does.
“Fortunately, optogenetic stimulation does not lead to muscle fatigue as prolonged and irregular electrical stimulation does.”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [556] source
The sections on light-induced diaphragmatic EMG activity and spinal plasticity report that breathing activity could persist after intermittent photostimulation, but they do not assess muscle fatigue. Searches for fatigue and electrical stimulation found no passage comparing fatigue under optical and prolonged, irregular electrical stimulation. Page numbers were unavailable in our copy. (LLM, conf=0.76)
Experimental — accuracy not yet measured
- Premisecitation
Flexible LEDs and microscale inorganic LEDs with biocompatibility have been reported to facilitate optogenetic stimulation of the central and peripheral nervous system.
“With the advances of materials science and manufacturing technologies, flexible light-emitting diodes (LED) [562] and microscale, inorganic LED (μ-ILED)[563] with biocompatibility have been reported to facilitate the progress in optogenetic stimulation for central and peripheral nervous system.”
Quote in the paperSubstantial claim2 of 2 sources checked- cites [562] source
The paper describes implantable microscale inorganic LEDs for wireless optogenetic stimulation in the brain, and its Optoelectronic Design section describes soft components intended to minimize tissue damage. Its introduction also mentions optoelectronic stimulation of peripheral nerves, but does not establish that the μ-ILED devices reported here were used for peripheral stimulation. (LLM, conf=0.82)
Experimental — accuracy not yet measured - cites [563] source
The paper’s Abstract describes biocompatible, mechanically compliant microscale inorganic LEDs and demonstrates their use for optogenetic stimulation in the mammalian brain. It does not report stimulation of the peripheral nervous system. The separate citation for flexible LEDs is not assessed here. (LLM, conf=0.86)
Experimental — accuracy not yet measured
- Premisecitation
Wraparound peripheral nerve interfaces can reduce foreign body reactions caused by insertion.
“The wraparound peripheral nerve interface can reduce foreign body reactions caused by insertion.[58,302,551,554]”
Quote in the paperNot a substantial claim2 of 4 sources checked- cites [58] source
- cites [302] source
The Abstract (page unavailable) reports that the wraparound MorphE interface had no significant increase in the ED1 inflammatory-response marker relative to sham controls, while conventional cuffs did. This supports reduced inflammation in this rat comparison, but not the claim that the reaction was caused by insertion: the paper points instead to implant detachment and chronic compression, rather than an initial injury. (LLM, conf=0.87)
Experimental — accuracy not yet measured - cites [551] source
- cites [554] source
The Surgical Procedure and Optical Fiber Implant Sites in Midbrain sections describe an optical fiber inserted into monkeys’ midbrains, not a wraparound peripheral nerve interface. The No Sign of Toxicity in the Brain by NIr section reports mechanical damage and gliosis along the fiber tract, but does not test whether a wraparound design reduces insertion-related foreign-body reactions. Searches for wraparound and peripheral nerve interfaces found no passage addressing that comparison; page numbers were not provided in our copy. (LLM, conf=0.76)
Experimental — accuracy not yet measured
- Premisecitation
Penetrating microelectrodes with low charge/phase thresholds, high charge density thresholds, and smaller surface area are more suitable for selective, high-spatial-resolution stimulation of specific functional brain areas.
“The first is penetrating microelectrodes with low-charge/phase thresholds, high-charge density thresholds and smaller surface area, which are more suitable for stimulating specific functional areas in a selective and high spatial resolution way.[543,544]”
Quote in the paperNot a substantial claim2 of 2 sources checked- cites [543] source
The Results and Discussion link smaller electrode dimensions to potentially higher spatial resolution, and the introductory passage calls for high charge-transfer capacity in cortical microelectrodes. But these points concern the paper’s surface-based porous graphene arrays, not penetrating microelectrodes. The copy does not establish the claimed low charge-per-phase thresholds, high charge-density thresholds, or superior selectivity of penetrating electrodes. (LLM, conf=0.81)
Experimental — accuracy not yet measured - cites [544] source
The Introduction (page unavailable) reports that intracortical microstimulation can provide somatosensory feedback and contrasts it with cortical surface stimulation, which may affect a large brain volume. It does not establish that penetrating microelectrodes have the stated charge thresholds or smaller surface area, or that they are more suitable for selective, high-spatial-resolution stimulation. (LLM, conf=0.74)
Experimental — accuracy not yet measured
- Premisecitation
Miniaturization or cuff shape is still the mainstream design of peripheral nerve optical stimulators.
“Therefore, miniaturization or cuff shape is still the mainstream design of peripheral nerve optical stimulators[572–575].”
Quote in the paperNot a substantial claim1 of 4 sources checked- cites [572] source
The “Optical nerve cuff construction” section describes a spiral cuff-shaped optical stimulator, so the paper supports cuff shape as an example of peripheral nerve stimulator design. It does not establish that cuff-shaped or miniaturized designs are the mainstream. (LLM, conf=0.84)
Experimental — accuracy not yet measured - cites [573] source
- cites [574] source
- cites [575] source
- Premisecitation
Integrating epidermal electrodes on amputees' remaining extremities has been tested in some studies.
“Integrating epidermal electrodes, which provide opportunities in intimate, long-term interfaces to the human body,[602] on amputees’ remaining extremities has been tested in some studies.[603]”
Quote in the paperNot a substantial claim1 of 2 sources checked- cites [602] source
The Design and self-assembly and In vivo implantation sections describe probes implanted in mouse brains, not epidermal electrodes tested on amputees’ remaining extremities. Searches for epidermal electrodes, amputees, and residual limbs found no passage addressing that claim in our copy. (LLM, conf=0.77)
Experimental — accuracy not yet measured - cites [603] source
- Premisecitation
A fully implantable, battery-free wireless optoelectronic device for spinal optogenetics avoids the tethered operation of traditional optic fiber implants.
“For example, a fully implantable, battery-free wireless optoelectronic devices for spinal optogenetics is illustrated in Figure 15I. [569] This device design avoids the tethered operation in traditional optic fiber implants.”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [569] source
The Introduction describes this paper’s battery-free, fully implantable wireless device, and the Results say wireless operation removes the need for physical handling. But the device studied is a cuff for peripheral nerves, not a spinal optogenetics implant; the References identify a separate Samineni et al. (2017) paper with the spinal-device title. This paper therefore supports the wireless, untethered design in general, but not the attribution of the spinal device to this study. (LLM, conf=0.88)
Experimental — accuracy not yet measured
- Premisecitation
A noninvasive electrical stimulation system consisting of a TENG array for power supply and a ball-shaped electrode array for current simulation allowed subjects to identify different virtual spatial patterns by spatio-temporal varying electrical stimulation.
“Figure 16D presents a noninvasive electrical stimulation system consisting of a TENG array for power supply and a ball-shaped electrode array for current simulation. Subjects wearing the system can identify different virtual spatial patterns by spatio-temporal varying electrical stimulation (Figure 16E and 16F).[604]”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [604] source
Split into 2 atoms — 0 confirmed, 0 partially supported, 0 disputed, 0 misattributed, 2 unverifiable. Expand the claim to see per-atom verdicts.
Experimental — accuracy not yet measured
- Premisecitation
The frequency and amplitude of vibration are keys to generating different types of sensory information in vibration stimulation.
“Whereas, the frequency and amplitude of the vibration are keys to generate different types of sensory information in the vibration stimulus.[360]”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [360] source
- Premisecitation
In high frequency vibration stimulation, piezoelectric stimulators based on the inverse piezoelectric effect are a good alternative.
“In this high frequency vibration stimulation, piezoelectric stimulators based on the inverse piezoelectric effect are also a good alternative.[595–597]”
Quote in the paperNot a substantial claim1 of 3 sources checked- cites [595] source
- cites [596] source
The discussion of stimulation electrodes (Figure 2a; page not supplied) says that electrical current can produce a vibration-like sensation. Searches for piezoelectric stimulators, the inverse piezoelectric effect, and high-frequency vibration found no passage assessing them as an alternative. (LLM, conf=0.75)
Experimental — accuracy not yet measured - cites [597] source
- Premisecitation
Many integrated flexible stimulation systems can also perform electrophysiological recording.
“Consequently, many integrated flexible stimulation systems can also perform electrophysiological recording.[52]”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [52] source
The paper’s introductory description (section E; page not provided) describes a compliant integrated probe that combines light delivery with long-term neural recording. The in vivo electrophysiology methods also report recording signals during optical stimulation. This supports the capability for the system studied, but not the broader claim that many flexible stimulation systems have it. (LLM, conf=0.85)
Experimental — accuracy not yet measured
- Interpretationcitation
Multiple performance characteristics of a device often have an implicated relationship, so optimizing one performance may bring another performance limitation (e.g., sensitivity vs. range, accuracy vs. softness).
“The multiple performance of the device often has an implicated relationship, the optimization of one performance may bring another performance limitation (such as sensitivity vs. range,[112] accuracy vs. softness[35] etc.)”
Quote in the paperNot a substantial claim2 of 2 sources checked- cites [112] source
- cites [35] source
The concluding discussion says soft robots are difficult to model and control, particularly when they must retain a desired body configuration, and calls for matching softness to the capabilities required. This supports a softness–control trade-off, but the paper does not establish the specific accuracy-versus-softness relationship attributed to citation [35]. The sensitivity-versus-range example is attached to a different citation. (LLM, conf=0.80)
Experimental — accuracy not yet measured
- Premisecitation
Some potential mass-processing technologies are emerging, such as laser-based processing, roll-to-roll printing, inkjet printing, and other technologies for flexible electronics that offer excellent and consistent performance while ensuring fast, low-cost manufacturing.
“To eliminate these issues, some potential mass-processing technologies are emerging, such as laser-based processing,[249,617] roll-to-roll printing,[618,619] inkjet printing,[620] and other technologies for flexible electronics that offer excellent and consistent performance while ensuring fast, low-cost manufacturing.”
Quote in the paperNot a substantial claim1 of 5 sources checked - Interpretationcitation
The long-term impact of these materials on the human body remains an uncertainty limiting the actual long-term commercial application of devices in HMI.
“However, the long-term impact of these materials on the human body remains an uncertainty limiting the actual long-term commercial application of the devices in HMI.”
Quote in the paperSubstantial claim1 of 2 sources checked- cites [607] source
The Introduction (page not provided) says biocompatibility warrants study because printed materials may contact skin for multiple days, and warns that leached metal ions could harm human tissue. The Results (page not provided) report a seven-day cell-viability test, but the paper does not say that uncertain long-term effects limit commercial HMI applications. (LLM, conf=0.82)
Experimental — accuracy not yet measured - cites [608] source
- Premisecitation
Some temperature-sensitive e-skins can outperform human skin in sensitivity, accuracy, and detection range.
“Currently, some temperature-sensitive e-skins can outperform the human skin in terms of sensitivity, accuracy, and detection range.[205,206]”
Quote in the paperNot a substantial claim0 of 2 sources checked - Interpretationreasoning
Through dual sensory communication and flexible robotic actuation, e-skin and soft robotics can restore lost sensory awareness in an extremity, letting the patient see the limb as an extension of the body.
“Through dual sensory communication and flexible robotic actuation, e-skin and soft robotics devices can restore the user’s lost sensory awareness in the extremity, allowing the patient to see the limb as an extension of their body rather than a lifeless mechanical appendage.”
Quote in the paperNot a substantial claim - Premisecitation
Noble metals such as platinum and gold are important in neural interface electrodes because of their chemical stability in physiological environments.
“For implantable devices, noble metals such as platinum (Pt) and gold (Au) play an important role in neural interface electrodes due to their chemical stability in physiological environments.[51]”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [51] source
- Premisecitation
For many prostheses, the same sensory information can be obtained through the user's stump.
“For many prostheses, the same sensory information can be acquired through the users’ stump.[19]”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [19] source
- Premisecitation
A flexible lightweight prosthetic system weighing 300 grams was developed that mimics a commercially available prosthetic device weighing more than 400 grams.
“For example, using flexible lightweight materials, a prosthetic system weighing 300 grams was developed that mimics a commercially available prosthetic device that weighs more than 400 grams.[76]”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [76]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Premisecitation
Sealing devices in biocompatible materials like polyimide or polydimethylsiloxane is a common technique for devices that are not chemically biocompatible.
“For devices that are not chemically biocompatible, the last commonly used technique is to completely seal the device in biocompatible material, like polyimide (PI) or polydimethylsiloxane (PDMS).[59]”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [59] source
- Premisecitation
Combining an electroactive polymer actuator with a hydraulic structure can improve actuation capability.
“the combination of electroactive polymer (EAP) actuator and hydraulic structure can improve actuation capability[62,63]”
Quote in the paperNot a substantial claim0 of 2 sources checked - Premisecitation
Gesture control using simple, accurate signals from non-invasive visible sensors has become an intuitive and reliable prosthetic control method.
“By using simple and accurate signal gathered from non-invasive and visible sensors, gesture control strategy has become an intuitive and reliable control method for prosthetics.[146]”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [146]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Interpretationreasoning
Flexible strain sensors are promising alternatives for monitoring mechanical signals because they are stretchable, durable, and lightweight.
“Flexible strain sensors prove to be promising alternatives to monitor these mechanical signals owing to their stretchability, durability, and lightweight nature.”
Quote in the paperSubstantial claim - Premisecitation
Nanomaterials and liquid metals can serve as electrodes in strain sensors because their conductivity remains stable under tensile strain.
“Nanomaterials[177,178] and liquid metals[179] can be used as electrodes owing to their stable conductivity under tensile strain.”
Quote in the paperNot a substantial claim0 of 3 sources checked - Premisecitation
High integration density of sensing arrays depends on fabrication process, materials, and data acquisition method.
“Achieving a high integration density of sensing arrays is dependent on the fabrication process, materials, and the data acquisition method.[128]”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [128] source
- Interpretationnone given
For many flexible devices, durability and functionality are only theoretical predictions or proof of concept.
“Although most studies mention durability and functionality, for many devices this is just a theoretical prediction or proof of concept.”
Quote in the paperSubstantial claim - Premisecitation
Piezoresistive sensors can be connected to the source or drain of an FET, where drain current varies with applied pressure.
“On the other hand, piezoresistive sensors can be connected to the source or drain of the FET, where the drain current of the FET varies with the applied pressure (Figure 4J).[48,77,133–135]”
Quote in the paperNot a substantial claim0 of 5 sources checked - Premisecitation
Piezoelectric materials such as BaTiO3, ZnO, and PVDF can be used to make strain sensors that convert strain into voltage signals.
“Piezoelectric materials, like BaTiO3,[183] zinc oxide (ZnO),[184] PVDF,[185,186] can be utilized to fabricate strain sensors by converting strain readings into voltage signals.”
Quote in the paperNot a substantial claim0 of 4 sources checked - Premisecitation
An active matrix approach, with transistors integrated around the device to control and amplify signals, can address crosstalk and interference from high integration density.
“An attractive approach to address this issue is to have transistors that maintain the sensing unit state integrated around the device to control and amplify the signal, namely the “active matrix”.[129]”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [129] source
- Premisecitation
Various flexible e-skin sensors mimicking human skin functions have been integrated onto medical robotics to sense external information for rehabilitation.
“In the past decade, various flexible e-skin sensors that mimic the functions and features of human skin have already been integrated onto medical robotics to sense external information[86] for rehabilitation applications.[87]”
Quote in the paperSubstantial claim0 of 2 sources checked - Premisecitation
Collecting strain and pressure information from a patient during rehabilitation can inform the therapist in real time about movement accuracy and physiological status.
“Collecting information from the patient during rehabilitation, specifically strain[89] and pressure,[90] can inform the therapist in real-time about the accuracy of the movement as well as the physiological status.”
Quote in the paperSubstantial claim0 of 2 sources checked - Premisecitation
A hybrid robotic skin can turn inanimate objects into soft robots by estimating their current position.
“This hybrid robotic skin can turn inanimate objects into soft robots by estimating their current position.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [200] source
- Premisecitation
Fatigue and psychological tension during rehabilitation can cause temperature variations through sweat evaporation.
“For example, the potential fatigue and psychological tension during the rehabilitation process can cause temperature variations due to sweat evaporation.[226]”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [226] source
- Premisecitation
An implantable capacitive multifunctional sensor was designed to measure pressure and strain signals under the skin.
“As shown in Figure 6G, an implantable capacitive multifunctional sensor was designed to measure pressure and strain signals under the skin.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [204] source
- Premisenone given
Identification of materials is inseparable from accurate temperature perception.
“One important lesson learned from studying the natural perception of human skin is that the identification of materials is inseparable from accurate temperature perception.”
Quote in the paperNot a substantial claim - Premisecitation
Flexible capacitive sensors combined with soft actuators can detect bending angles for self-perception.
“A noteworthy example to detect bending angles, an essential part of its self-perception, is flexible capacitive sensors alongside soft actuators.”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [200] source
- Interpretationreasoning
The design of these strain sensors provides a new paradigm for in vivo biomechanical measurements.
“The design of these strainers provide a new paradigm for in vivo biomechanical measurements.”
Quote in the paperNot a substantial claim - Premisecitation
A stable flexible strain gauge based on an island-and-gap structure of aligned CNT thin films was demonstrated.
“As shown in Figure 6D, a stable flexible strain gauge based on the “island and gap” structure of aligned CNT thin films was recently demonstrated.[175]”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [175] source
- Premisecitation
Monitoring body temperature at different locations can reflect the body's physiological and psychological state in real time.
“In the field of medical rehabilitation, monitoring body temperature at different locations can reflect the body's state (both physiological and psychological) in real time.”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [226] source
- Premisecitation
Flexible strain sensors can sense stretching and relaxation of prosthetics similarly to mechanoreceptors in muscles, skin, and tendons.
“In particular, flexible strain sensors can sense the stretching and relaxation of prosthetics like the human body's mechanoreceptors located on the muscles, skin, and tendons.[197]”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [197] source
- Premisecitation
Using this strain gauge for hand rehabilitation, a data glove can be fabricated to accurately detect each finger's motion individually.
“Using this strain gauge for hand rehabilitation, a data glove can be fabricated to accurately detect the motion of each finger individually.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [175] source
- Premisecitation
In vivo strain sensing has been investigated to monitor inner tissue such as tendons and muscle recovery by continuously providing real-time, long-term information for rehabilitation surveillance.
“In addition to monitoring external strain on the human skin, recently in vivo strain sensing has been investigated to monitor inner tissue, e.g. tendons and muscle recovery, by continuously providing real-time and long-term information for rehabilitation surveillance.[179,204]”
Quote in the paperNot a substantial claim0 of 2 sources checked - Premisecitation
An EGaIn-based strain sensor can be applied on top of the ankle to measure joint angle and provide feedback on foot motion during rehabilitation.
“Figure 6E presents an EGaIn based-strain sensor that can be applied on top of the ankle to measure the joint’s angle to provide feedback on the foot’s motion during rehabilitation.[201]”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [201] source
- Premisecitation
Conductive nanomaterial-filled polymers are promising for flexible PTC temperature sensors, where volume changes through the melting point of crystalline regions affect resistance.
“Conductive nanomaterial-filled polymers[212,213] are a promising candidate for flexible PTC temperature sensors, where the volume changes as the material progresses through the melting point of crystalline regions, thus affecting the resistance.[214]”
Quote in the paperNot a substantial claim0 of 3 sources checked - Premisecitation
On the skin, respiratory waves and pulses cause slight stretches that sensitive strain sensors can capture for health monitoring during rehabilitation.
“On the skin, respiratory waves and pulses can also contribute to slight stretches, which can be captured by sensitive strainers for health monitoring during rehabilitation.[94,202,203]”
Quote in the paperNot a substantial claim0 of 3 sources checked - Premisecitation
Some biomaterial- and structure-based designs have superior temperature response properties, offering another method for thermal perception.
“Some remarkable designs based on biomaterials and structures have superior temperature response properties, offering another method for thermal perception.[97]”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [97] source
- Premisecitation
Resistive metallic temperature detectors work because resistance and temperature are linear in metals.
“The mechanism of resistive metallic temperature detectors relies on the linearity between resistance and temperature found in metals.[209]”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [209] source
- Premisecitation
In demonstration, the e-skin provided real-time thermal information, force directions, and strain graphics in various tactile motions.
“In the demonstration, it can provide real-time thermal information, force directions, and strain graphics in various tactile motions (shear, pinch, spread, torsion; Figure 7G).”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [230] source
- Premisereasoning
Sweat can potentially communicate health and rehabilitation progress to the user, informing when to rehydrate and replenish electrolytes.
“In this regard, sweat can potentially communicate to the user about health and rehabilitation progress, informing the user when to rehydrate and replenish electrolytes.”
Quote in the paperNot a substantial claim - Premisereasoning
Flexible sensors attached to prostheses and human skin generally require compliant flexible characteristics, which limits e-skin thickness.
“First, flexible sensors attached to prostheses and human skin generally require compliant flexible characteristics, which places a limit on the thickness of e-skins.”
Quote in the paperSubstantial claim - Premisecitation
A cross-reactive sensor matrix based on machine learning can respond to a wide range of stimuli rather than specific stimuli like lock-and-key sensors.
“Another promising multimodal detection method based on machine learning is the “cross-reactive” sensor matrix. Instead of responding to certain specific stimuli like conventional “lock and key” sensors, this sensor has the ability to respond to a wide range of stimuli.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [231] source
- Interpretationreasoning
Dual-monitoring devices greatly enrich the external information available to prosthetic haptics.
“These dual-monitoring devices greatly enriches the external information that can be acquired by prosthetic haptics.”
Quote in the paperSubstantial claim - Premisecitation
Transistor-based approaches including FET and OECT show promise because they can amplify detected signals in situ.
“In addition to conventional electrochemical biosensing techniques, the transistor-based approach, including field-effect transistors (FET) and organic electrochemical transistors (OECT) also show great promise owing to their ability for in situ amplification of the detected signal.[235,236]”
Quote in the paperNot a substantial claim0 of 2 sources checked - Premisecitation
Changes in resistive or dielectric properties of these materials as they absorb moisture reflect humidity in the air.
“The change in the resistive or dielectric properties of these materials as they absorb moisture is used to reflect the humidity in the air.[256–258]”
Quote in the paperNot a substantial claim0 of 3 sources checked - Premisecitation
Existing flexible humidity sensors are mainly made by placing transducing materials such as graphene, CNT, and MoS2 on flexible substrates.
“Existing flexible humidity sensors are mainly fabricated by accommodating different transducing materials, such as graphene, CNT, and MoS2, on flexible substrates.”
Quote in the paperNot a substantial claim0 of 3 sources checked - Premisenone given
Chemical sensors for prosthetic and robotic applications have been less investigated than mechanical and thermal sensors.
“Chemical sensors for prosthetic and robotic applications have been less investigated than mechanical and thermal sensors.”
Quote in the paperNot a substantial claim - Premisecitation
The first stretchable e-skin that decoupled temperature and strain in a single parameter has an electrode-electrolyte-electrode structure.
“The first stretchable e-skin that decoupled temperature and strain in a single parameter is shown in Figure 7F.[230] The e-skin has a simple electrode-electrolyte-electrode structure, where two variables (temperature and strain) are”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [230] source
- Premisecitation
Harvesting brain signals as an information source has the advantage that the brain is the source of motor intention, reducing delay between conscious action and robotic actuation.
“Firstly, the brain acts as the source of motor intention, which is essential to reduce the delay time between conscious action and robotic actuation.[332]”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [332] source
- Premisenone given
Bioelectrical signals propagating through the nervous system can be detected both in vivo and on the skin surface using electrodes.
“Such bioelectrical signals propagating through the nervous system can be detected both in vivo and on the skin’s surface (using electrodes).”
Quote in the paperSubstantial claim - Premisenone given
Implantable electrodes embedded under the skin or inserted into target tissue, especially around deep or delicate tissues, are more accurate than non-invasive electrodes because they obtain substantially more biological signals.
“Implantable electrodes that are embedded under the skin or inserted into the target tissue, especially around deep or delicate tissues, are more accurate than non-invasive electrodes as they obtain substantially more biological signals.”
Quote in the paperNot a substantial claim - Premisereasoning
Because impedance adds noise, lower-impedance electrodes are expected to have a higher signal-to-noise ratio overall.
“As impedance adds noise to the signal, lower impedance electrodes are expected to have a higher signal-to-noise ratio (SNR) overall.”
Quote in the paperNot a substantial claim - Premisecitation
Biocompatibility is the determining factor for the safety and stability of implants in long-term chronic operation.
“Biocompatibility is the determining factor for the safety and stability of implants in long-term chronic operation (see section 2).[304]”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [304] source
- Premisereasoning
The performance requirements of implantable sensing neural interfaces lie primarily in device impedance, and hence conductivity and capacitance.
“Apart from the biocompatibility, the requirements of implantable sensing neural interfaces for good performance lie primarily in the device impedance, and hence conductivity and capacitance.”
Quote in the paperNot a substantial claim - Premisereasoning
Using electrophysiological signals to capture and decode movement intention can provide a natural way to control prosthetics.
“Utilizing these electrophysiological signals to capture and decode the movement intention can provide a natural way to control prosthetics.”
Quote in the paperSubstantial claim - Premisecitation
Traditional commercial implantable neural interfaces typically contain noble metals and silicon-based materials as electrodes.
“Traditional commercial implantable neural interfaces (e.g., Utah electrodes[306] and Michigan electrodes[307]) typically contain noble metals[308] (high conductivity and chemical stability), and silicon-based materials[309] (ideally suited to existing microfabrication techniques) as electrodes.”
Quote in the paperNot a substantial claim0 of 3 sources checked - Premisecitation
Low electrode impedance combined with distributed capacitance between electrodes and the recording amplifier enhances the electrode's high-frequency response.
“Moreover, low electrode impedance combined with the distributed capacitance between the electrodes and the recording amplifier will enhance the high-frequency response performance of the electrode.[305]”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [305] source
- Premisecitation
Various adapted peripheral electrodes have been proposed, including cuff electrodes, flat interface nerve electrodes, wire electrodes, longitudinal interfascicular electrodes, and transverse interfascicular multichannel electrodes.
“Various adapted peripheral electrodes have been proposed, such as implants around the nerve (cuff electrodes[351] and flat interface nerve electrodes (FINE)[352]), longitudinally through the nerves (wire[353] and longitudinal interfascicular electrodes (LIFE)[354]), and through the nerves via shafts (such as transverse interfascicular multichannel electrodes (TIME)[355]).”
Quote in the paperNot a substantial claim0 of 3 sources checked - Premisecitation
A TENG-powered ECG recording system conformed around a pig heart successfully performed real-time wireless cardiac monitoring.
“For example, Figure 8J demonstrates a TENG-powered ECG recording system conformed around a pig heart. Owing to the triboelectric material, which couples the contact electrification and electrostatic induction mechanism in the heartbeat (Figure 8K), and the structure, the device successfully performed real-time wireless cardiac monitoring (Figure 8L).[382]”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [382] source
- Premisereasoning
Flexible dry epidermal electrodes based on conductive materials and stretchable structures overcame drawbacks of commercial clinical electrodes.
“In contrast, flexible dry epidermal electrodes based on conductive materials and stretchable structures overcame these drawbacks.”
Quote in the paperSubstantial claim - Premisecitation
Conventional brain-machine interfaces with probe-like morphology for local field potential recordings are generally small and rigid.
“Conventional BMIs with probe-like morphology for LFP recordings are generally small and rigid.[338]”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [338] source
- Premisecitation
Users prefer a modality-matched feedback system where vibrations are felt as vibrations and temperature as heat.
“Specifically, users prefer a modality-matched feedback system where vibrations are felt as vibrations and temperature is felt as heat.[19]”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [19] source
- Premisecitation
An ultrasonic backscattering concept-based neural dust demonstrated stable wireless ENG and EMG recording from the sciatic nerve and gastrocnemius muscle.
“In one representative example, an ultrasonic backscattering concept-based neural dust demonstrated stable wireless ENG and EMG recording from the sciatic nerve and the gastrocnemius muscle respectively (Figure 8G).”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [372] source
- Premisecitation
By adding AI to these neurons, researchers created a neuromorphic tactile processing system (NeuTap) that captures spatiotemporal tactile features with 0.4% accuracy.
“Integrating artificial intelligence into these neurons, researchers further developed a neuromorphic tactile processing system (NeuTap) that acquires tactile sensory information with a 0.4% accuracy for spatiotemporal features.[442]”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [442]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Interpretationreasoning
A drawback of support vector machines and k-nearest neighbors is that the input features to the machine learning models might not be readily available.
“The drawback to using these algorithms is that the input features to the ML models might not be readily available.”
Quote in the paperNot a substantial claim - Premisecitation
Support vector machines have been successfully used in soft robotics tactile sensing to identify objects with 98.1% accuracy.
“Meanwhile, SVMs have been successfully used by soft robotics in tactile sensing to identify objects with an accuracy of 98.1%.[448]”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [448]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Interpretationreasoning
Convolutional neural networks have an advantage over other machine learning algorithms such as artificial neural networks because they require little preprocessing on most imaging data, since information is compressed later inside the network.
“The benefit of CNNs over other ML algorithms (such as ANNs), however, is that there is little preprocessing required on (most) imaging data as the information will inevitably be compressed later inside the network.”
Quote in the paperNot a substantial claim - Premisecitation
An asynchronously coded electronic skin (ACES) can send data from 10,000 sensors over one wire with a 1-millisecond latency.
“Recently, an asynchronously coded e-skin (ACES) was developed that can simultaneously transmit information from 10,000 sensors using only a single wire with a latency period of 1 millisecond (Figure 10C and 10D).[433]”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [433] source
- Interpretationreasoning
Machine learning accuracy naturally declines over time.
“This results in the natural decline of the ML accuracy over time.”
Quote in the paperNot a substantial claim - Premisecitation
In medical robotics, k-nearest neighbors has been shown to outperform other machine learning techniques including support vector machines for proprioception sensing when training a soft robotic hand to recognize bending and twisting angles.
“In medical robotics, the KNN algorithm has been shown to outperform other ML techniques (including SVMs) for proprioception sensing when training a soft robotic hand to recognize its bending and twisting angles.[199]”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [199] source
- Interpretationcitation
A commonly overlooked issue in machine learning applications is sampling enough data points across all gender, race, age, and sexuality.
“Another issue commonly overlooked in ML applications is sampling enough data points across all gender, race, age, and sexuality.[449]”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [449] source
- Premisecitation
Artificial neural networks classified 5 hand gestures from 8 EMG electrodes with 98.7% accuracy.
“as well as 5 hand gestures from 8 EMG electrodes with an accuracy of 98.7%.[447]”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [447] source
- Premisecitation
Despite performing well in training groups, Amazon's Rekognition facial recognition software preferentially labeled innocent people in minority groups as potential criminals in practice.
“Despite performing well in training groups, in practice, Rekognition was found to preferentially label innocent people in minority groups as potential criminals.[450]”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [450]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Premisecitation
Most commercial prostheses have only about 4 degrees of freedom because of the complexity of computing control signals for multiple rigid motors.
“In contrast, most commercial prostheses have only about 4 DOFs[455,456] due to the complexity of computing control signals for multiple rigid motors.”
Quote in the paperSubstantial claim0 of 2 sources checked- cites [455] source
- cites [456]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Premisecitation
Many studies have focused on structural design of EAPs, such as parallel connections and hydraulic amplification, to amplify force output.
“In order to amplify the force output, a lot of studies have focused on the structural design of EAPs, like parallel connections[491] and hydraulic amplification.[62,492]”
Quote in the paperNot a substantial claim0 of 3 sources checked - Premisecitation
In motor-based tendon-driven devices, cables in the form of variable length tendons are embedded in soft or rigid skeletons to provide controlled deformation.
“In these devices, cables in the forms of variable length tendons are embedded in soft or rigid skeletons to provide a controlled deformation.[482,483]”
Quote in the paperNot a substantial claim0 of 2 sources checked- cites [482] source
- cites [483]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Premisenone given
Intimate conformal contact with the skin promotes heat transfer between heaters and skin.
“Intimate conformal contact with the skin promoting heat transfer between heaters and skin.”
Quote in the paperNot a substantial claim - Interpretationreasoning
Soft-robotic systems show great potential in medical and wearable applications.
“Soft-robotic systems therefore show great potential in medical and wearable applications.[462–464]”
Quote in the paperSubstantial claim0 of 3 sources checked - Interpretationcitation
A soft wearable 3D printed robotic ankle-foot orthosis with a bi-directional tendon-driven actuator, integrated with a gait sensing module, has the potential to improve hemiplegic gait after stroke.
“Through the integration of the device with the gait sensing module, the system has the potential to improve hemiplegic gait after stroke (Figure 13F).[496]”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [496] source
- Premisecitation
A wearable robotic device powered by pneumatic artificial muscles in ankle-foot rehabilitation provides active assistance without restricting natural degrees of freedom at the ankle joint.
“Figure 13E shows the design and control of a wearable robotic device powered by pneumatic artificial muscles in ankle-foot rehabilitation which provides active assistance without restricting natural DOFs at the ankle joint.[495]”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [495] source
- Interpretationcitation
Dedicated tendon-driven actuating systems are suitable for bi-directional actuation in foot rehabilitation.
“Dedicated tendon driven actuating systems are suitable for bi-directional actuation in foot rehabilitation.”
Quote in the paperNot a substantial claim - Premisecitation
The actuation stress, strain, and efficiency of EAPs are problematic for prosthetic applications, especially for ionic polymer actuators.
“However, the actuation stress, strain, and efficiency of EAPs (aforementioned in section 2.1.4) are problematic in applications to prosthetics, especially for ionic polymer actuators.[490]”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [490]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Interpretationnone given
Soft wearable robotics offers an opportunity for rehabilitation, especially in motion therapy.
“The field of soft wearable robotics offers an opportunity for rehabilitation, especially in motion therapy.”
Quote in the paperNot a substantial claim - Interpretationnone given
Thermal actuators provide an additional dimension beyond mechanical and electronic for human-machine interfaces.
“Thermal actuators provide an additional dimension beyond mechanical and electronic for HMI.”
Quote in the paperNot a substantial claim - Premisecitation
Combining two planes of HASEL actuators with simultaneous capacitance measurements can reflect the actuation state of a robotic arm.
“The combination of two planes of HASEL actuators with simultaneous capacitance measurements can be used to reflect the actuation state of the robotic arm (Figure 12I).[62]”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [62] source
- Interpretationreasoning
Combining the actuating ability of dielectric elastomer actuators and all-soft matter hydraulic architectures can greatly amplify the output force of HASEL actuators.
“Combining the actuating ability of dielectric elastomer actuators and all–soft matter hydraulic architectures, the output force of hydraulically amplified self-healing electrostatic (HASEL) actuators can be greatly amplified.”
Quote in the paperSubstantial claim - Premisecitation
Exosuits produce gait-restorative joint torques by transmitting mechanical power from waist-mounted body-worn or off-board actuators to the wearer through textile anchors and cable-based transmission.
“Exosuits produce gait-restorative joint torques by transmitting mechanical power from waist-mounted body-worn or off-board actuators to the wearer through the interaction of textile anchors and cable-based transmission (Figure 13D).[494]”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [494] source
- Premisecitation
Due to its sensing and actuating abilities, the soft hand has been successfully applied in grasping and human-machine interface scenarios.
“Due to its sensing and actuating abilities, the soft hand has been successfully applied in grasping and HMI scenarios (Figure 12B and 12C).[153]”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [153] source
- Premisecitation
Soft pneumatic actuators can be deformed in a controlled manner through inflation or evacuation of special structures or external binding modes such as fiber shells.
“Soft pneumatic actuators can be deformed in a controlled manner through inflation or evacuation of special structures[469] or external binding modes (fiber shells).[470]”
Quote in the paperNot a substantial claim0 of 2 sources checked - Premisenone given
Stimulation modalities can transmit biopotential electrical, optical, or mechanical signals to the body for sensation.
“Specifically, stimulation modalities can transmit biopotential electrical, optical, or mechanical signals to the body for sensation.”
Quote in the paperSubstantial claim - Premisecitation
Compared to rigid thermoelectric coolers, the performance of all flexible Peltier cooling devices is far from adequate for human-machine interface use.
“However, compared to rigid thermoelectric coolers, the performance of all flexible Peltier cooling devices is far from adequate for HMI use.[510]”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [510] source
- Interpretationreasoning
Implantable electrical stimulators are widely used because they are compatible with the body's electrical signaling.
“Therefore, implantable electrical stimulators are widely deployed because of signal compatibility.”
Quote in the paperNot a substantial claim- Rests on an assumption: Electrical signals are the predominant form of nerve excitation in the human body.
- Interpretationreasoning
Peltier cooling is a promising solution for providing both heating and cooling in thermal feedback.
“Peltier cooling is a promising solution for the challenge.”
Quote in the paperNot a substantial claim - Premisecitation
In rehabilitation therapy, stimulations have been prescribed to treat disabilities caused by neurological disorders through neural modulation, such as deep brain stimulation for paralysis and Parkinson's disease.
“In rehabilitation therapy, stimulations have also been prescribed to treat disabilities caused by neurological disorders through neural modulation, such as deep brain stimulation for paralysis and Parkinson's disease.[305,520]”
Quote in the paperNot a substantial claim0 of 2 sources checked - Premisecitation
A thermo-haptic device is based on a thermally conductive elastomer backbone and thermoelectric materials connected with stretchable interconnecting electrodes, enabling heat transfer under maximum stretching over 230%.
“The device is based upon a thermally conductive elastomer backbone and thermoelectric materials connected with stretchable interconnecting electrode, which enables heat transfer under maximum stretching over 230%.[501]”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [501] source
- Premisecitation
Capacitive electrical stimulators inject charge mainly through double-layer charge at electrode-electrolyte interfaces.
“The capacitive type relies mainly on the double-layer charge at the electrode-electrolyte interfaces to inject charge”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [305] source
- Premisecitation
With medical imaging and genetic labelling, epidural and subdural electrical stimulators can be integrated on the spinal cord for sensory feedback and motor function modulation as linear-type or paddle-type probes.
“With the aid of medical imaging and genetic labelling technologies, epidural and subdural electrical stimulators could be integrated on spinal cord for sensory feedback and motor function modulation in forms of linear-type probes and paddle-type probes.[86]”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [86] source
- Premisereasoning
Electrode material is a decisive factor in the electrical performance of implantable stimulation electrodes.
“Electrode material is a decisive factor in the electrical performance of implantable stimulation electrodes.”
Quote in the paperSubstantial claim - Premisecitation
The paddle-like neural implant e-dura can achieve long-term biological integration in the central nervous system of the spinal cord.
“Figure 15C shows a paddle like neural implants named “e-dura”, which can have long-term biological integration in the central nervous system of spinal cord.[548]”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [548] source
- Premisecitation
e-dura was effectively used to restore locomotion in a rat after spinal cord injury.
“Finally, this e-dura was effectively exploited to restore locomotion of a rat after spinal cord injury (Figure 15D).”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [548] source
- Premisecitation
A wireless bioresorbable electronic system using a Mg layer embedded in insulating polymer to deliver electrical stimuli enhanced neuroregeneration and functional recovery in rodent models.
“Utilizing a deposited layer of Mg embedded in insulting polymer to deliver electrical stimuli from the receiver antenna to the tissue, the system successfully enhanced neuroregeneration and functional recovery in rodent models (Figure 15F).[303]”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [303] source
- Premisereasoning
The large surface area of nanomaterials can enhance charge injection capabilities.
“On the other hand, the considerable surface area of nanomaterials can enhance charge injection capabilities.”
Quote in the paperNot a substantial claim - Premisenone given
Nanomaterials can form percolation networks that adapt to neural tissue deformation while maintaining high electrical performance.
“Nanomaterials can constitute percolation networks that can adapt to the deformation of neural tissue while maintaining high electrical performance.”
Quote in the paperNot a substantial claim - Interpretationreasoning
Conductive polymers' intrinsic mechanical elasticity and favorable charge storage and injection capacity make them an unparalleled option for faradic electrical stimulators.
“The intrinsic mechanical elasticity, favorable charge storage and injection capacity of conductive polymers provide an unparalleled option for faradic electrical stimulators.”
Quote in the paperNot a substantial claim - Interpretationcitation
The variability and over-time drift of skin impedance present perplexing challenges for electrotactile stimulation.
“Nevertheless, the variability and over time drift of skin impedance also present perplexing challenges for electrotactile stimulation at the same time.[598]”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [598] source
- Interpretationnone given
Emerging noninvasive tactile stimulation methods (transdermal electrical, mechanical, thermal feedback) provide alternative solutions for stimulating the human body in prosthetic and rehabilitation applications.
“Emerging noninvasive tactile stimulation methods, like transdermal electrical, mechanical stimulation, thermal feedback (introduced in section 6.2.2), provide alternative solutions to stimulate the human body for prosthetic and rehabilitation applications.”
Quote in the paperSubstantial claim - Interpretationnone given
These mechanisms can output significantly larger forces and deformation for static force stimulation.
“These mechanisms are able to output significantly larger forces and deformation for static force stimulation.”
Quote in the paperNot a substantial claim - Interpretationnone given
For fully implantable optogenetic stimulators, device mass and size have a nonnegligible effect on an animal's freedom of movement and behavior by preventing entry into small enclosures or normal social interactions.
“Additionally, for fully implantable optogenetic stimulators, the mass and size of the devices have a nonnegligible effect on the animal’s freedom of movement and behavior by preventing animals from entering small enclosures or engaging in normal social interactions with others.”
Quote in the paperSubstantial claim - Interpretationreasoning
Flexible epidermal electrotactile displays have the potential to replace mechanical haptic displays because of advantages such as small and thin size, lightweight, and rapid responsiveness.
“It has the potential to replace mechanical haptic displays owing to several advantages, such as small and thin size, lightweight and rapid responsiveness.”
Quote in the paperNot a substantial claim - Premisecitation
A wireless optogenetic device weighing 20-50 mg is two orders of magnitude smaller and lighter than previously reported wireless optogenetic systems.
“Figure 15K and 15L demonstrate a wireless optogenetic devices weigh 20–50 mg, which is two orders of magnitude smaller and lighter than previously reported wireless optogenetic systems.[574]”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [574] source
- Premisecitation
The type of perception evoked by feedback depends mainly on different mechanical stimulation parameters.
“From a physiological point of view, the type of perception evoked by the feedback depends mainly on the different mechanical stimulation parameters.”
Quote in the paperNot a substantial claim - Premisecitation
Flexible epidermal electrotactile displays provide stimulation by applying electric current through the skin surface.
“Flexible epidermal electrotactile display is another haptic interface that provides stimulation by applying an electric current through the skin surface.[430]”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [430] source
- Premisecitation
A matrix of 15 SMA-based plasters attached to human skin allows the user to perceive different touch patterns through tangential and shear forces generated by SMAs and changes in the location of working units.
“For example, a matrix composed of 15 SMA-based plasters can be attached to human skin, and the user can perceive different touch patterns through the tangential and shear forces generated by SMAs and changes in the location of working units.[584]”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [584] source
- Interpretationreasoning
The need for coils and permanent magnets, which are usually rigid, makes electromagnetic stimulators occupy a large volume.
“However, the need for coils and permanent magnets, which are usually rigid, always makes such stimulators occupy a large volume.”
Quote in the paperNot a substantial claim - Premisecitation
The low response speed and hysteresis of fluidic and heat-induced deformation stimulators limit both mechanisms to stimulating the skin in the form of high frequency vibrations.
“Nonetheless, the low response speed and hysteresis of fluidic and heat-induced deformation stimulators limit both mechanisms to stimulate the skin in the form of high frequency vibrations.[585]”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [585] source
- Premisecitation
Perception of the residual limb can be elicited by mechanical stimulation such as vibration and static force stimulation.
“Perception of the residual limb can be elicited by mechanical stimulation, such as vibration and static force stimulation.”
Quote in the paperNot a substantial claim - Premisecitation
For arraying stimulators, feedback stimulation can be achieved with continuous temporal and spatial variation.
“For arraying stimulators, the feedback stimulation can be achieved with continuous temporal and spatial variation.[578]”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [578] source
- Interpretationreasoning
TENGs provide a potential solution to achieve self-powered, wireless electrical stimulation.
“TENGs provide a potential solution to achieve self-powered, wireless electrical stimulation.”
Quote in the paperSubstantial claim - Premisecitation
This combination therapy can achieve independent rehabilitation without a guide.
“This combination therapy can achieve independent rehabilitation without a guide.[158]”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [158] source
- Interpretationreasoning
For medical rehabilitation, system integration is critical to achieve precise treatment and assess rehabilitation efficacy.
“For medical rehabilitation, system integration is also critical to achieve precise treatment and assess rehabilitation efficacy.”
Quote in the paperNot a substantial claim - Premisenone given
Such stimuli can be converted into electrophysiological signals through artificial synapses, which are then fed back into the body through flexible stimulators.
“Such stimuli can be further converted into electrophysiological signals through artificial synapses, which are then fed back into the body through flexible stimulators.”
Quote in the paperNot a substantial claim - Interpretationreasoning
Interface issues for signal relay are a major challenge in HMI robotics, specifically for mechanical and electrical components.
“Interface issues for signal relay are a major challenge in HMI robotics, specifically for mechanical and electrical components.”
Quote in the paperSubstantial claim - Premisenone given
Evaluation of optogenetic stimulation relies mainly on real-time recording of in situ electrophysiological signals.
“The evaluation of optogenetic stimulation relies mainly on real-time recording of the in situ electrophysiological signals.”
Quote in the paperNot a substantial claim - Premisereasoning
With the aid of soft robotic hand motions, flexible e-skins can acquire various signals from the exterior environment.
“With the aid of soft robotic hand motions, flexible e-skins can then acquire various signals from the exterior environment.”
Quote in the paperNot a substantial claim
- May combine two claims. 191
- Classified as probably not a substantial claim. 137
- The quote only partly states this claim. 1
May combine two claims.
PremisecitationThe PN junction method has advantages of small size, fast response time, and good linearity.
“The advantage of this method is its small size, fast response time, and good linearity.[106,217]”
Quote in the paperNot a substantial claim1 of 2 sources checked- cites [106] source
In the section on SiNR sensors (page unavailable), the paper describes the diode temperature sensors’ nonlinear characteristics as an advantage, contrary to the claimed advantage of good linearity. Its statement that sensors have a linear and fast response concerns SiNR strain gauges, not the p–n-junction temperature sensors; the cited passages also do not establish small size as an advantage of the junction method. (LLM, conf=0.79)
Checked by a reasoning model — may be wrong.
Experimental — accuracy not yet measured - cites [217] source
Probably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationSome locomotor system diseases cause abnormal elevations of metabolites and biomarkers, such as L-dopa in Parkinson's disease and uric acid in gout.
“Moreover, some diseases of the locomotor system provoke abnormal elevations of metabolites and biomarkers, such as L-dopa in Parkinson’s disease[246–248] uric acid in gout,[45] which are very important evaluation factors.”
Quote in the paperNot a substantial claim3 of 4 sources checked- cites [246] source
The Introduction (page unavailable) describes levodopa as a treatment for Parkinson’s disease, not as a metabolite or biomarker abnormally elevated by the disease. Searches for elevated L-dopa, biomarker concentrations, and related terms found no passage addressing that claim. The separate gout example is cited to another source, not this paper. (LLM, conf=0.76)
Experimental — accuracy not yet measured - cites [247] source
The Levodopa Monitoring > Abstract passages describe L-dopa as a medication for Parkinson’s disease, not a biomarker elevated by the disease. The on-body study reports increased sweat L-dopa after fava-bean consumption and almost zero concentration without it. The gout example has a separate citation and is not assessed against this source. (LLM, conf=0.85)
Checked by a reasoning model — may be wrong.
Experimental — accuracy not yet measured - cites [248] source
The paper’s Abstract supports monitoring L-Dopa levels to guide Parkinson’s disease treatment. It does not support the claim that Parkinson’s disease itself causes L-Dopa to rise: the reported increase followed an oral L-Dopa tablet, and the measurements were made in healthy volunteers. Uric acid in gout is attached to a different citation in the citing sentence. (LLM, conf=0.88)
Experimental — accuracy not yet measured - cites [45] source
May combine two claims.
Premisecitation2D porous materials facilitate sweat outflow and evaporation, are comfortable to wear, and cause little skin irritation.
“Due to their breathability, these aforementioned 2D porous materials facilitate the outflow and evaporation of sweat and are not only comfortable to wear but also do not cause much skin irritation.[75]”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [75] source
The Results section (page unavailable) reports that the paper’s perforated e-skin lets sweat and vapor pass through and caused no skin irritation in a one-week forearm test. The Introduction describes its low mass as suitable for imperceptible wear. These findings support the claim for this specific e-skin, but not for 2D porous materials generally. (LLM, conf=0.84)
Experimental — accuracy not yet measured
May combine two claims.
PremisecitationE-skin and soft robotics together can alleviate limited functionality, heavy weight, and poor aesthetic design.
“Together, e-skin and soft robotics can therefore alleviate problems such as limited functionality,[37] heavy weight,[19] and poor aesthetic design.[31]”
Quote in the paperSubstantial claim1 of 3 sources checked- cites [37] source
- cites [19] source
- cites [31] source
Citation [31] is attached to the aesthetic-design part of the sentence. The Prosthetic Hands and Fingers section describes robotic or bionic prostheses with life-like, aesthetically pleasing outer shells, supporting the possibility of improved appearance. It does not establish that e-skin and soft robotics together produce that improvement. (LLM, conf=0.83)
Experimental — accuracy not yet measured
May combine two claims.
PremisecitationCoating hydrogels on electronics or mixing conductive materials such as CNTs, ionic liquids, or conductive polymers into the gel can maintain biocompatibility while preserving electronic properties.
“Coating hydrogels on electronics[55] or mixing conductive materials such as carbon nanotubes (CNTs),[56] ionic liquids,[57] or conductive polymers[58] into the gel can help maintain biocompatibility while also preserving the electronic properties.”
Quote in the paperNot a substantial claim2 of 3 sources checkedMay combine two claims.
PremisecitationHydrogels can reduce inflammatory response to foreign objects, regulate cell or protein attachment, and prevent device failure in vivo.
“As a material whose features resemble water-rich tissue in the human body, hydrogels can greatly reduce the inflammatory response of foreign objects, regulate cell or protein attachment, and prevent device failure in vivo,[52] which is important for implants.[53,54]”
Quote in the paperNot a substantial claim3 of 3 sources checked- cites [52] source
The ‘Assessment of the foreign body response’ section (page not specified) reports a substantially reduced response to implanted hydrogel hybrid probes after 1, 3, and 6 months. The paper also reports stable recording performance in mice, but it does not establish that hydrogels generally prevent device failure in vivo. Its Discussion presents cell-adhesion enhancers as a possible future addition, not a demonstrated ability to regulate cell or protein attachment. (LLM, conf=0.88)
Experimental — accuracy not yet measured - cites [53] source
The paper’s introductory passage (indexed as Abstract; page unavailable) says hydrogels resemble human tissues and may serve as coatings for long-term bio-integration. Its discussion of device reliability concerns robust hydrogel–component interfaces under deformation, not prevention of failure in vivo. The copy does not report reduced foreign-body inflammation or regulation of cell or protein attachment. (LLM, conf=0.86)
Experimental — accuracy not yet measured - cites [54] source
The ‘Advancing the state of the art in implanted electrodes’ section says hydrogels or other soft coatings can help clear inflammatory factors, and that functionalized surface coatings can regulate cell or protein attachment (page unavailable). It does not say hydrogels greatly reduce inflammation or prevent device failure in vivo; its examples of attachment control include PEG and ECM coatings. (LLM, conf=0.87)
Experimental — accuracy not yet measured
May combine two claims.
PremisecitationTo replace rigid electronics, e-skin needs low mechanical modulus, aesthetic appearance, low cost, lightweight design, large-scale fabrication, self-healing, and thermal stability.
“To make the replacement from current rigid electronics, e-skin requires a low mechanical modulus (high stretchability),[28–30] aesthetic appearance,[31] low-cost,[32] lightweight design,[29] large-scale fabrication techniques,[32] self-healing properties,[30] and be thermally stable.[29]”
Quote in the paperNot a substantial claim2 of 5 sources checked- cites [28] source
The Introduction (page not provided) contrasts low-modulus, compliant flexible electronics with bulky, rigid systems, and §2.2 identifies modulus and stretchability as important for skin contact. §2.5 describes an ultra-lightweight wearable device. The paper does not establish thermal stability as a requirement for e-skin; the citing sentence attaches this source to that point as well. Its other listed properties are assigned to other citations. (LLM, conf=0.85)
Experimental — accuracy not yet measured - cites [29] source
- cites [30] source
- cites [31] source
The Introduction’s “Aesthetics” section says soft-tissue prostheses should look realistic and aesthetically pleasing. The cited paper discusses prosthetic materials, however, not aesthetic appearance as a requirement for e-skin replacing rigid electronics. In the citing sentence, this source appears attached only to “aesthetic appearance,” not to the other listed properties. (LLM, conf=0.82)
Experimental — accuracy not yet measured - cites [32] source
May combine two claims.
PremisecitationWearable robotics also have shortcomings including limited environmental feedback, limited power supply, and failure to autonomously respond appropriately to external stimuli.
“Additional shortcomings include their limited environmental feedback, power supply, and failure to autonomously respond appropriately to external (possibly dangerous) stimuli.[24]”
Quote in the paperSubstantial claim1 of 1 sources checked- cites [24] source
May combine two claims.
Premisecitation3D flexible electronics maintain conductivity while gaining an extra dimension and more sophisticated functions than 2D electronics.
“Notably, 3D flexible electronics maintain conductivity while gaining an extra dimension and thus more sophisticated functions that 2D electronics do not offer (Figure 3E and 3F).[70–72]”
Quote in the paperNot a substantial claim2 of 3 sources checked- cites [70] source
The ‘Route to morphable 3D mesostructures and electronics’ section (page unavailable) reports unchanged transistor characteristics after a 3D shape change, while its LED example shows that electrical connectivity can change with the assembly route. The ‘Morphable 3D radio frequency electronic devices’ section describes shape-dependent functions, including a circuit that switches between a filter and an inductor. These examples support retained electrical operation and added reconfigurable functions, but not the blanket claims that conductivity is always maintained or that 2D electronics cannot offer those functions. (LLM, conf=0.85)
Experimental — accuracy not yet measured - cites [71] source
In “Inspired by Wind-Dispersed Seeds” (page unavailable), the paper describes converting planar electronic precursors into 3D fliers and reports electrical properties consistent with devices made on planar wafers. It also demonstrates functional 3D fliers, but does not establish the broader claim that 3D flexible electronics offer more sophisticated functions unavailable to 2D electronics. (LLM, conf=0.84)
Experimental — accuracy not yet measured - cites [72] source
May combine two claims.
PremisecitationProsthetics can be controlled by neural electrophysiological signals and by mechanical signals such as gestures or body movements.
“Prosthetics can be controlled by neural electrophysiological signals (will be further discussed in section 4) and mechanical signals such as gestures[189,190] or body movements.[191]”
Quote in the paperNot a substantial claim2 of 3 sources checked- cites [189] source
- cites [190] source
The Results and Discussion section reports that sensors detecting finger bending and gestures transmitted signals to control a robotic hand. It does not identify that hand as a prosthesis. This citation is attached to the gesture-control part of the sentence, not the separate claims about neural signals or body movements; the gesture mechanism is supported, but its application to prosthetics is not established by this paper. (LLM, conf=0.84)
Experimental — accuracy not yet measured - cites [191] source
The Results section (“Wearable closed-loop HMI system”; page unavailable) shows that sensors detect shoulder and hand movements and use those signals to control a robotic hand. The paper calls it a robotic hand with prosthetic skin, not a prosthesis used by a person, so it supports movement-based control but not that application specifically. Citation [191] is attached to “body movements,” not to the separate claim about neural electrophysiological signals. (LLM, conf=0.82)
Experimental — accuracy not yet measured
May combine two claims.
PremisecitationCapacitive sensors have excellent linearity with lower power consumption than resistive sensors.
“Compared with resistive sensors, capacitive sensors have excellent linearity with lower power consumption.[119]”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [119] source
The Results and Discussion (p. 5) state that the capacitive sensor had better linearity than the resistive sensor, and Figure 2 (p. 3) reports a linear capacitive response. Our copy does not report lower power consumption for the capacitive sensor; a search for power consumption found no supporting passage. (LLM, conf=0.87)
Experimental — accuracy not yet measured
Probably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationTransparency based on polymers or nanomesh materials contributes to greater aesthetic properties of flexible devices.
“Furthermore, the transparency based on polymers, or nanomesh materials, also contributes to greater aesthetic properties of flexible devices.[77,78]”
Quote in the paperNot a substantial claim1 of 2 sources checked- cites [77] source
- cites [78] source
The Abstract and Introduction (pages not provided) describe transparent polymer-based elastomers for flexible electronics and explain that a lack of transparency hinders optical applications. They do not say transparency improves a device’s aesthetic properties or discuss nanomesh materials. (LLM, conf=0.83)
Experimental — accuracy not yet measured
Probably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationThermocouples generate a potential difference under temperature differences between different materials based on the Seebeck effect.
“Thermocouples can generate a potential difference under different temperature between different materials based on the thermoelectric (Seebeck) phenomenon.[216]”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [216] source
Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
PremisecitationIn medical rehabilitation, temperature sensing is commonly used to monitor the body and can serve as a health reference.
“In medical rehabilitation, temperature sensing is commonly used to monitor the body, which can be a reference for health.[225,226]”
Quote in the paperNot a substantial claim1 of 2 sources checked- cites [225] source
The Results section on continuous exercise monitoring describes axillary temperature as a marker of health and performance and demonstrates its measurement during exercise. The Discussion identifies rehabilitation as a possible application for full-body monitoring, but does not say temperature sensing is commonly used in rehabilitation. (LLM, conf=0.85)
Experimental — accuracy not yet measured - cites [226] source
May combine two claims.
PremisecitationAn organic active matrix with polymer PTC sensor pads fabricated on a PI substrate exhibits bending insensitivity and high spatial resolution.
“For measuring spatial temperature gradients, an organic active matrix with polymer PTC sensor pads was fabricated on a PI substrate, which exhibits a bending insensitivity and high spatial resolution (Figure 7A and 7B).[103]”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [103] source
May combine two claims.
PremisecitationThe human hand, as a heat source and sensor, can perceive heat dissipation ability for fluid flow rate sensing and identify thermal characteristics of surface materials.
“As a heat source and sensor, the human hand can effectively perceive the heat dissipation ability for fluid flow rate sensing[223] and identifying the thermal characteristics of surface materials.[224]”
Quote in the paperNot a substantial claim1 of 2 sources checkedProbably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationIn PN junction temperature sensors, forward voltage varies with temperature, converting heat into electrical signals in diodes and transistors.
“Whereas the forward voltage in PN junction temperature sensors can vary with temperature, converting the heat into electrical signals in the diodes and transistors.”
Quote in the paperNot a substantial claim1 of 2 sources checked- cites [106] source
The ‘Characterization of SiNR temperature sensors’ section (page unavailable) describes p–n-diode sensors calibrated by plotting voltage at a fixed current against temperature. This supports the temperature-dependent voltage claim for diodes, but the cited passages do not establish it for transistors. (LLM, conf=0.85)
Experimental — accuracy not yet measured - cites [217] source
Probably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationA robotic hand equipped with e-skin grabbed and measured the temperature of different cups.
“Researchers demonstrated the sensor’s functions by using a robotic hand equipped with e-skin to grab and measure the temperature of different cups. (Figure 7D)”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [222] source
In “Intrinsically stretchable rubbery sensors for robotic skins” (pp. 5–6), the paper describes temperature sensors on a robotic hand touching hot and cold cups and records their responses. It says the hand touched the cups, but does not establish that it grabbed them. (LLM, conf=0.84)
Experimental — accuracy not yet measured
May combine two claims.
PremisecitationLong-term body temperature monitoring with flexible temperature sensors is convenient and can effectively prevent medical abnormalities such as foot ulcers.
“Long-term monitoring of body temperature by using flexible temperature sensors is convenient and can effectively prevent medical abnormalities such as foot ulcers.[227]”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [227] source
The Introduction (page unavailable) describes wearable sensors intended to monitor body, skin, and ulcer temperature, and says a temperature rise can warn of ulcer onset. But the Introduction says continuous wearable ulcer-temperature monitoring was not yet available, while the Conclusion (page unavailable) says the sensors still needed clinical validation. The paper therefore does not establish that convenient long-term monitoring with these sensors effectively prevents foot ulcers. (LLM, conf=0.88)
Experimental — accuracy not yet measured
May combine two claims.
PremisecitationSweat detection can respond in real time to changes in sweat volume and rate and to concentrations of ions and metabolites.
“Sweat detection can respond in real-time to changes in the volume and rate of sweat loss,[241,242] as well as the concentration of various ions and metabolites in the body.[45,243–245]”
Quote in the paperSubstantial claim3 of 6 sources checked- cites [241] source
The Introduction (page unavailable) describes real-time sweat-biomarker sensing, and the Results section on aquatic and dryland athletes reports measurements of sweat volume, rate, and chloride concentration. It does not demonstrate real-time measurement of changes in all these quantities: the Methods say volume and chloride readings were taken after exercise. The Results discuss metabolite testing as a potential application, not a demonstrated measurement. (LLM, conf=0.84)
Experimental — accuracy not yet measured - cites [242] source
- cites [45] source
- cites [243] source
- cites [244] source
The Introduction describes real-time measurement of local sweat volume and rate, and the Results section on smartphone-based analysis describes measuring sweat volume and chloride concentration. The cited paper does not establish detection of various metabolites or measurement of ion and metabolite concentrations in the body; its demonstrated chemical measurement is sweat chloride. (LLM, conf=0.87)
Experimental — accuracy not yet measured - cites [245] source
May combine two claims.
PremisecitationAdding chemical sensing to prostheses can prevent users from exposure to harmful chemicals and reduce potential harm.
“Thus, adding chemical sensing capability to prostheses can prevent users from being exposed to harmful chemicals, such as organophosphate pesticide residues in agricultural products, and subsequently reduce the potential risk of harm.[239]”
Quote in the paperSubstantial claim1 of 1 sources checked- cites [239] source
The Introduction (page unavailable) says organophosphate pesticide residues in agricultural products pose a health threat and that remote robotic sampling can avoid placing people in unsafe environments. The study equips robotic manipulators with chemical sensors, not prostheses worn by users, so it does not establish that adding sensing to prostheses prevents users’ exposure or reduces their risk of harm. (LLM, conf=0.88)
Experimental — accuracy not yet measured
May combine two claims.
PremisecitationSweat sensing can monitor patient fatigue and support psychological applications by monitoring stress hormones such as cortisol and norepinephrine.
“In addition to monitoring patient fatigue, sweat sensing can also be used for psychological applications by monitoring the level of stress hormones such as cortisol and norepinephrine.[249,250]”
Quote in the paperNot a substantial claim1 of 2 sources checked- cites [249] source
The Introduction describes sensing cortisol in sweat for stress monitoring, and the Conclusion proposes applications in mental-health monitoring while noting that the study tested only physical stress stimuli. The cited paper does not support monitoring norepinephrine or patient fatigue. (LLM, conf=0.88)
Experimental — accuracy not yet measured - cites [250] source
May combine two claims.
PremisecitationChemical sensing is not sufficiently developed for prosthesis, but sweat chemical sensing is well-studied and highly relevant to rehabilitation exercises.
“Although chemical sensing is not sufficiently developed for prosthesis, in the field of health monitoring, sweat chemical sensing (including electrochemical and optical modalities) is well-studied and highly relevant to rehabilitation exercises.[240]”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [240] source
The State-of-the-Art Wearable Sweat Sensors section (page unavailable) describes electrochemical and optical sweat sensing and its use in fitness and health monitoring. It does not assess whether chemical sensing is sufficiently developed for prostheses or establish that sweat sensing is highly relevant to rehabilitation exercises; its exercise discussion concerns fitness monitoring. (LLM, conf=0.87)
Experimental — accuracy not yet measured
Probably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationWith smartphone cameras, quantitative color measurement is highly attractive for in-home monitoring of optical sensors.
“In recent years, with the popularity of smartphone cameras, the quantitative measurement of color is highly attractive for in-home monitoring of optical sensors.[237]”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [237] source
The Results (Hybrid, battery-free, skin-mounted system for sweat sensing; page unavailable) say a smartphone camera captures images for colorimetric analysis, and Materials and Methods (Data collection and analyses; page unavailable) describes using those images to determine sweat chloride and pH. The paper does not establish that smartphone-camera popularity makes quantitative color measurement attractive for in-home monitoring of optical sensors generally. (LLM, conf=0.84)
Experimental — accuracy not yet measured
May combine two claims.
PremisecitationMotor intention originates from the primary motor cortex and is transmitted from the central to peripheral nervous system as electrophysiological signals, which are translated into mechanical muscle contractions.
“Motor intention originates from the primary motor cortex of the brain and is transmitted from the central nervous system to the peripheral nervous system in the form of electrophysiological signals, which are translated into mechanical contractions of the muscles.[269]”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [269] source
The Abstract reports that the interface derived motor commands from neuronal activity in primary motor cortex (M1). It does not establish that motor intention originates there or describe signals traveling from the central to the peripheral nervous system and producing muscle contractions; the interface instead bypassed the body. No page number is provided in our copy. (LLM, conf=0.84)
Experimental — accuracy not yet measured
May combine two claims.
PremisecitationE-skin can exhibit greater functionality than human skin, such as proximity and magnetic field sensing, complementing natural skin and allowing HMI devices to obtain richer environmental information.
“Due to new sensing mechanisms, e-skin can exhibit greater functionality beyond the human skin, such as proximity[259,260] and magnetic field sensing,[261,262] which can be seen as complements to the natural skin capabilities, allowing HMI devices to obtain richer information about the external environment.”
Quote in the paperNot a substantial claim2 of 4 sources checkedProbably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
PremisecitationPPG uses optical differences between vascular and other tissues or oxygenated and deoxygenated hemoglobin to measure heart rate, blood oxygen, and other cardiovascular information.
“PPG uses optical differences between the vascular and other tissues or oxygenated and deoxygenated hemoglobin to measure heart rate,[263] blood oxygen,[267] and other in-depth cardiovascular information.[268]”
Quote in the paperNot a substantial claim2 of 3 sources checked- cites [263] source
The citation [268] is attached to “other in-depth cardiovascular information.” In the Ultraflexible organic photodetectors section (page not specified), the paper says reflected light tracks blood-vessel volume pulsation, but it reports calculating pulse rate and does not identify other in-depth cardiovascular measurements. (LLM, conf=0.78)
Experimental — accuracy not yet measured - cites [267] source
- cites [268]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
May combine two claims.
PremisecitationSubcutaneous invasive electrophysiological signals can be obtained through brain interfaces, ECoG on the cortical surface, and LFPs from electrodes inserted into the cortex.
“Subcutaneous invasive electrophysiological signals can be derived through brain interfaces,[270–272] using electrocorticography (ECoG)[273,274] on the cortical surface as well as local field potentials (LFP)[275,276] extracted from electrodes inserted into the cortex.”
Quote in the paperNot a substantial claim3 of 7 sources checkedProbably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
PremisecitationCommon wearable techniques include EEG, sEMG, and EOG, which capture electrical activity of the brain, muscles, and eye movements respectively.
“Common wearable techniques include electroencephalography (EEG),[281,282] surface electromyography (sEMG),[283,284] and electrooculography (EOG),[285] which capture the electrical activity of the brain, muscles, and eye movements respectively.”
Quote in the paperNot a substantial claim1 of 5 sources checkedMay combine two claims.
PremisecitationECoG electrodes are generally placed on the cerebral cortex surface and can collect signals without penetrating tissue, with a larger recording area and relatively less brain damage.
“In contrast, ECoG electrodes are generally placed on the surface of the cerebral cortex and can collect signals without penetrating the tissue, with a larger recording area with relatively less damage to the brain.[270]”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [270] source
The passage labeled Abstract describes ECoG as recording with subdural grid electrodes on the cortical surface, in contrast to electrodes placed in the brain for LFP recordings. This supports surface recording without penetrating brain tissue, but our copy does not establish a larger recording area or relatively less brain damage. (LLM, conf=0.87)
Experimental — accuracy not yet measured
May combine two claims.
PremisecitationWireless transmission of data and energy for flexible implants can reduce messy wires and improve user mobility and social interaction.
“Recently, there has been a focus on wireless transmission of data and energy for flexible implants, which can reduce messy wires and improve user mobility and social interaction.[325]”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [325] source
The “Limitations of tethered systems” section reports that, compared with untethered mice, mice with fiber tethers had reduced mobility and social interaction. The paper also discusses flexible components for wireless implants, but the cited behavioral comparison concerns animals; it does not establish improved mobility or social interaction for human implant users. (LLM, conf=0.84)
Experimental — accuracy not yet measured
May combine two claims.
PremisecitationCompared with rigid electrodes based on silicon wafers and rigid packaging, flexible electrodes are more biocompatible and can adapt to complex tissue geometries.
“Compared to commercially available rigid electrodes based on silicon wafers and rigid packaging, flexible electrodes are also more biocompatible (details described in section 2) and can adapt to the complex tissue geometries of the human body,[293–295] such as sulci in the cerebral cortex,[296,297] bundled peripheral nerves,[298] and stretching motions on the skin.[299]”
Quote in the paperSubstantial claim5 of 6 sources checked- cites [293] source
The Introduction says that subcellular electrode designs such as carbon fiber arrays reduce mechanical mismatch and inflammatory impact, which supports part of the biocompatibility rationale. It does not establish a comparison between flexible and rigid electrodes or say that flexible electrodes conform to complex tissue geometries. No page number is available in our copy. (LLM, conf=0.74)
Experimental — accuracy not yet measured - cites [294]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [295] source
The Results (p. 3) say the soft electrodes can be adapted to the anatomy of cortical, spinal, and peripheral-nerve tissues, and the technology description (p. 4) calls their materials biocompatible. The paper does not establish that they are more biocompatible than rigid silicon-wafer electrodes, nor does it demonstrate adaptation to human anatomy. (LLM, conf=0.88)
Experimental — accuracy not yet measured - cites [296] source
The Abstract (page not provided) says flexible, non-penetrating subdural arrays minimize irritation and injury to brain tissue compared with penetrating arrays. Electrode array fabrication and testing (page not provided) shows that this flexible device can fold to access cortical sulci. The paper does not establish a comparison with commercially available silicon-wafer electrodes and rigid packaging, or show that flexible electrodes adapt to complex tissue geometries throughout the human body. (LLM, conf=0.86)
Experimental — accuracy not yet measured - cites [297] source
The Introduction says flexible neural probes comply with brain tissue, and the Results (Long-term chronic stability of Neurotassels; page unavailable) report less neuronal cell loss around Neurotassels than around silicon probes in mice. This supports a brain-implant biocompatibility advantage, but the paper does not establish that flexible electrodes adapt to complex geometries throughout the human body. (LLM, conf=0.88)
Experimental — accuracy not yet measured - cites [298] source
May combine two claims.
PremisecitationInsulative packaging materials are a critical part of sensing recorders, and many popular insulating soft materials have been used for packaging sensing electrodes.
“Apart from the conductive functional materials, the insulative packaging materials are also a critical part of sensing recorders. Many popular insulating soft materials have been used for packaging sensing electrodes,[318] such as PI,[319,320] PDMS,[321,322] hydrogel,[323,324] etc., as they have suitable mechanical, dielectric and biological properties.”
Quote in the paperNot a substantial claim1 of 5 sources checkedMay combine two claims.
PremisecitationVarious electrodes with different materials, shapes, and characteristics can be placed on or in the brain, peripheral nerves, and muscles to record ECoG, LFP, ENG, and EMG respectively.
“Various electrodes, with different materials, shapes, and characteristics, can be places on or in the human brain, peripheral nerves, and muscles to record ECoG,[300] LFP,[301] ENG[302] and EMG[303] respectively.”
Quote in the paperNot a substantial claim2 of 3 sources checked- cites [300] source
- cites [301] source
- cites [302] source
The Methods describe electrodes implanted around rat sciatic nerves and electrophysiological recording of evoked compound action potentials. This supports peripheral-nerve monitoring, the portion linked to citation [302], but the recording electrodes were placed in the rat hind paw; the paper does not establish ENG recording from electrodes on or in human peripheral nerves. (LLM, conf=0.86)
Experimental — accuracy not yet measured
May combine two claims.
PremisecitationECoG and LFPs play an important role in examining motor intention and elucidating the pathogenesis of neurological disorders such as epilepsy and Parkinson's disease.
“As invasive brain monitoring electrodes, ECoG and LFPs play an important role in examining motor intention and elucidating the fundamental pathogenesis of various neurological disorders, such as epilepsy and Parkinson’s disease.[330,331]”
Quote in the paperNot a substantial claim2 of 2 sources checked- cites [330] source
The paper describes using ECoG to study motor movement and imagery, supporting the motor-intention portion of the claim. The Methods describe epilepsy as the reason participants had electrodes implanted, not as a disorder whose pathogenesis was investigated. The paper does not establish the claimed role for LFPs or investigate Parkinson’s disease pathogenesis. (LLM, conf=0.88)
Experimental — accuracy not yet measured - cites [331] source
The Introduction describes cortical and subcortical field potentials as probes of neural synchronization, and the Results use those recordings to decode motor states in people with Parkinson’s disease. The paper does not establish that they examine motor intention or elucidate the fundamental pathogenesis of epilepsy; epilepsy is mentioned in the Introduction as a condition treated with implanted stimulation devices. (LLM, conf=0.86)
Experimental — accuracy not yet measured
May combine two claims.
PremisecitationWith further processing technology, these materials can be fabricated into ultra-thin and ultra-fine forms, enabling high-density integration and some flexibility.
“With further evolution of processing technology, these materials can be fabricated into ultra-thin and ultra-fine forms, thus enabling high-density integration, as well as endowing some flexibility.[310,311]”
Quote in the paperNot a substantial claim2 of 2 sources checkedMay combine two claims.
PremisecitationIn vivo ECG recording equipment on the surface of the heart is subjected to dynamic movement, unlike static neural implants.
“Unlike static neural implants mentioned above, in vivo ECG recording equipment on the surface of the heart is subjected to dynamic movement.[375–378]”
Quote in the paperSubstantial claim3 of 4 sources checked- cites [375] source
The Biological modulation section (page unavailable) describes flexible devices contacting a rat heart’s surface while the heart contracted, supporting the dynamic-movement aspect. But Methods: Isolated heart (page unavailable) says the heart was removed for these ECG experiments; the paper does not establish an in vivo cardiac recording setup or the comparison with static neural implants. (LLM, conf=0.85)
Experimental — accuracy not yet measured - cites [376] source
- cites [377] source
In “Assembly of a fully viscoelastic device and in vivo validation” (page not provided), the paper reports that an electrode array recorded ECG on a mouse heart and remained in place as the heart continued to beat. This supports the dynamic-movement point, but the paper does not characterize neural implants as static or establish the stated contrast. (LLM, conf=0.84)
Experimental — accuracy not yet measured - cites [378] source
May combine two claims.
PremisecitationMicro-wires are becoming flexible alternatives to microneedle arrays; they can remain relatively stationary as the brain moves, improving signal stability and reducing tissue damage.
“As materials and manufacturing processes evolve, more micro-wires are becoming flexible alternatives to microneedle arrays, which are able to remain relatively stationary as the brain moves, improving signal stability while reducing tissue damage.[339–342]”
Quote in the paperNot a substantial claim3 of 4 sources checked- cites [339] source
The Introduction (p. 3) says the fine carbon fibers are much more compliant than conventional tungsten microwires and may reduce biological response; the Abstract (p. 1) likewise describes reduced inflammation as a promise of the technology. The paper does not show that the electrodes remain stationary as the brain moves or that this improves signal stability. Its in vivo recording demonstration was acute, so it does not establish reduced tissue damage over time. (LLM, conf=0.86)
Experimental — accuracy not yet measured - cites [340] source
The Methods describe chronically implanted microwire arrays, and the Results report stable recordings over recording sessions and viable single-unit recordings 18 months after implantation (page unavailable in our copy). The Discussion contrasts slow microwire implantation with the Utah array. The paper does not establish that the microwires flex to remain stationary as the brain moves, or that this mechanism improves signal stability or reduces tissue damage; its reference to design flexibility concerns which microwires the circuit board can accommodate. (LLM, conf=0.85)
Experimental — accuracy not yet measured - cites [341] source
The Introduction (page unavailable) describes thin, flexible polymer probes as an alternative to rigid electrode arrays and says their flexibility should improve biocompatibility. The Threads section describes a design intended to minimize tissue displacement. The paper does not say these probes remain relatively stationary as the brain moves or that this improves signal stability; it also does not demonstrate reduced tissue damage. (LLM, conf=0.86)
Experimental — accuracy not yet measured - cites [342] source
May combine two claims.
PremisecitationSurface electrodes are generally more flexible, with morphology either 1D or 2D thin electrode layers or very tiny electrodes.
“In contrast, surface electrodes generally are more flexible,[364,369] whose morphology in the limited space between this epimysium and the skin is either 1D or 2D thin electrode layers[370,371] or very tiny electrodes (millimeter or even sub-millimeter level).[369,372]”
Quote in the paperNot a substantial claim2 of 5 sources checked- cites [364] source
- cites [369] source
The Epimysial recordings section (p. 4) describes a flexible, 20 µm-thick electrode substrate with submillimeter detection sites, supporting this paper as an example of a thin, flexible electrode. It does not establish that surface electrodes generally are more flexible than other electrodes; its devices are epimysial electrodes mounted on muscle. (LLM, conf=0.84)
Experimental — accuracy not yet measured - cites [370] source
- cites [371] source
The Results describe a flexible printed circuit board with 0.2 × 0.2 mm recording pads that contact nerve or muscle, and a mote placed on a muscle surface beneath the replaced skin. This supports the cited example of a tiny surface-contact electrode, but does not establish that surface electrodes are generally more flexible than other electrodes. The 1D/2D morphology clause cites other sources, not this paper. (LLM, conf=0.84)
Experimental — accuracy not yet measured - cites [372] source
May combine two claims.
PremisecitationENG signals have a low signal-to-noise ratio and limited stability.
“Nevertheless, ENG signals have a low signal-to-noise ratio and limited stability.[363]”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [363] source
The Materials and methods section (Figure 2 description; page unavailable) says LIFE signals commonly have quite low signal-to-noise ratios. The Discussion (page unavailable) describes the interface as quite stable during the trials and says long-term stability still needs investigation, so it does not establish the claimed limited stability. (LLM, conf=0.88)
Experimental — accuracy not yet measured
May combine two claims.
PremisecitationA flexible filamentary bioinspired neuron-like electronic has bending stiffness comparable to a neuron's axon, enabling biocompatible high-resolution local field potential recording.
“The bending stiffness of this implant is comparable to that of a neuron’s axon, enabling biocompatible high-resolution LFP recording.[310]”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [310] source
The Design and characteristics section states that the NeuE interconnect’s calculated bending stiffness is comparable to a neuron’s axon. The Summary and outlook reports negligible immune response, and Stable single-unit recording following implantation reports stable recordings of individual neurons. Our copy does not establish high-resolution local field potential (LFP) recording; its recording results concern single-unit spikes. (LLM, conf=0.88)
Experimental — accuracy not yet measured
The quote only partly states this claim.
Study design and conductcitationIn vivo Vagus nerve stimulation on a rabbit demonstrated the validity of the twining plant-inspired device.
“In vivo Vagus nerve stimulation was carried out on a rabbit to demonstrate the validity of the device (Figure 8F).”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [358] source
May combine two claims.
PremisecitationIn vitro and on-body artificial sensory neurons can communicate to batches of afferent cells using optical methods, but currently lack ability to selectively connect with individual neurons.
“While in vitro and on-body artificial sensory neurons can communicate to batches of afferent cells using optical methods, they currently lack the ability to selectively connect with individual neurons (Figure 10A).[426,427]”
Quote in the paperSubstantial claim1 of 2 sources checked- cites [426] source
The Background and Methodology > Sensory feedback system passages describe prosthetic-hand feedback through auditory cues, not optical communication with afferent cells. Searches for artificial sensory neurons, optical methods, and selective connections to individual neurons found no passage addressing the claim in our copy; page numbers were unavailable. (LLM, conf=0.76)
Experimental — accuracy not yet measured - cites [427] source
May combine two claims.
PremisecitationInaccurate communication channels in medical robotics go against visual cues, leading to cognitive confusion, which is the number one reason why 40% of amputees reject wearing a prosthetic device.
“The problem with inaccurate communication channels in medical robotics is that it goes against visual cues from the user leading to cognitive confusion,[428] which is the number one reason why 40% of amputees reject wearing a prosthetic device.[19]”
Quote in the paperNot a substantial claim1 of 2 sources checked- cites [428] source
The citation to this paper follows the claim that cognitive confusion is the leading reason 40% of amputees reject prostheses. The Introduction discusses the lack of sensory feedback, and Materials and Methods describes experiments with one amputee, but neither reports a rejection rate or identifies cognitive confusion as a reason for rejection (searched: 40%, rejection, abandonment, visual cues). (LLM, conf=0.78)
Experimental — accuracy not yet measured - cites [19] source
Probably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationConvolutional neural networks have been shown to detect Alzheimer's disease in MRI images.
“CNNs have additionally been shown to detect Alzheimer’s disease in MRI images.[445]”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [445] source
The Introduction discusses convolutional neural networks only as classifiers for hand-gesture recognition. The Method and Conclusions describe an ANN using surface EMG signals, not MRI images. Searches for Alzheimer’s disease and MRI found no passage addressing the attributed claim. (LLM, conf=0.76)
Experimental — accuracy not yet measured
May combine two claims.
PremisecitationMost single tendon drives cannot actuate bidirectionally, so multiple cables are required to recover structures, similar to human agonist and antagonistic muscles.
“It is worth noting, most single tendon drive does not have the ability to actuate bidirectionally (no”
Quote in the paperNot a substantial claim2 of 2 sources checked- cites [486] source
The Introduction (page unavailable) describes electro-ionic soft actuators as artificial muscles, and the Results (page unavailable) discuss their bending performance. Searches for single-tendon drives, bidirectional actuation, multiple cables, and agonist–antagonist muscles found no passage addressing the claimed limitation or cable requirement. (LLM, conf=0.75)
Experimental — accuracy not yet measured - cites [487] source
The Methods section describes a string attached to the motor’s rotor to measure torque, but does not discuss single-tendon drives. The Results and discussion passages concern dielectric-elastomer actuation, not whether tendon drives require multiple cables for bidirectional motion or recovery. Searches for tendon, cable, bidirectional actuation, and agonist–antagonist muscles found no passage addressing the claim; page numbers were not provided. (LLM, conf=0.76)
Experimental — accuracy not yet measured
May combine two claims.
PremisecitationSkin-like thermal actuators can be used for prosthetic applications, AR/VR feedback thermal stimulators, and thermal therapy in rehabilitation.
“Specifically, these skin-like thermal actuators can be used for prosthetic applications,[106,502] AR/VR feedback thermal stimulators,[191,503,504] and thermal therapy in rehabilitation.[505–507]”
Quote in the paperNot a substantial claim3 of 8 sources checked- cites [106] source
- cites [502] source
The Introduction and Results describe conformal thermal actuators used to heat skin at low levels and measure thermal transport; the Introduction says the experimental heating was below the human sensory threshold. The Discussion mentions dermatological studies and monitoring, but our copy does not address prosthetic use, AR/VR thermal feedback, or rehabilitation therapy (searched: prosthetic applications, feedback, rehabilitation, and therapeutic heating). (LLM, conf=0.73)
Experimental — accuracy not yet measured - cites [191] source
- cites [503] source
- cites [504] source
- cites [505] source
- cites [506] source
- cites [507] source
Probably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationThe term tendon driven is generic because the tendon can be powered by many sources, such as shape memory alloys, shape memory polymers, and thermo-responsive polymers.
“The name is a generic term, because the “tendon” can be powered by many sources, such as shape memory alloys (SMAs),[479] SMPs,[480] and thermo-responsive polymers[481].”
Quote in the paperNot a substantial claim1 of 3 sources checkedMay combine two claims.
PremisecitationThere are two types of pneumatic actuators: pneumatic artificial muscles (McKibben actuators) for linear actuation and fluidic elastomer actuators, composed of low durometer rubber and driven by low air pressure (3-8 psi) for bending.
“Broadly speaking, there are two types of pneumatic actuators: PAM-pneumatic artificial muscles (known as McKibben actuators) for linear actuation[471–473] and FEA- fluidic elastomer actuators, which are composed of low durometer rubber and driven by relatively low air pressure (3–8 psi) for bending.[474–476]”
Quote in the paperNot a substantial claim1 of 6 sources checked- cites [471]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [472] source
- cites [473]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [474] source
- cites [475]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [476]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
May combine two claims.
PremisecitationPneumatic and tendon actuation can be applied to gloves, exoskeletons, and foot orthoses, providing a new paradigm for rehabilitation devices.
“These two actuation methods can be applied to gloves, exoskeletons, and foot orthoses, providing a new paradigm for rehabilitation devices.[459]”
Quote in the paperSubstantial claim1 of 1 sources checked- cites [459] source
Section 2.3 describes an electrically heated nitrile glove that provides thermal feedback, not pneumatic or tendon actuation. Searches for pneumatic and tendon actuation, exoskeletons, foot orthoses, and rehabilitation found no passage addressing the attributed claim. The copy provides no page number for Section 2.3. (LLM, conf=0.78)
Experimental — accuracy not yet measured
May combine two claims.
PremisecitationEAP actuators are activated directly through electrical signals, unlike soft pneumatic actuators that need gas supplements and tendon-driven actuators that require motors.
“In contrast to soft pneumatic actuators that demand gas supplements and tendon driven actuators that require motors, EAP actuators are activated directly through electrical signals.[488,489]”
Quote in the paperNot a substantial claim1 of 2 sources checked- cites [488] source
- cites [489] source
The Introduction (page unavailable) says traditional pneumatic or hydraulic actuators require external compressors or pumps to supply pressurized fluid, and describes electrically responsive actuators. It does not discuss tendon-driven actuators or establish that they require motors; its electrically powered examples also do not substantiate the statement about EAP actuators as a class. (LLM, conf=0.86)
Experimental — accuracy not yet measured
May combine two claims.
InterpretationcitationEndowing e-skins with temperature can help amputees interact with others and improve acceptance of prostheses in social touch situations.
“Endowing e-skins with”
Quote in the paperSubstantial claim1 of 1 sources checked- cites [502] source
The Introduction describes conformal thermal sensors for measuring skin temperature and thermal transport, while the Methods study healthy volunteers. Neither those passages nor the additional searches for amputees, prostheses, and social touch address whether temperature-enabled e-skins improve social interaction or prosthesis acceptance. (LLM, conf=0.76)
Experimental — accuracy not yet measured
May combine two claims.
PremisecitationCommon substrate materials for soft implants include PI and hydrogel, which are chemically inert in vivo and have sufficient dielectric strength to prevent discharge breakdown.
“Common substrate materials include PI and hydrogel, which can remain chemically inert in vivo while also providing sufficient dielectric strength to prevent discharge breakdown.”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [515] source
The Discussion sections on specificity, invasiveness, and heating risks discuss implantable optical devices and electrode insulation, but not PI or hydrogel substrates. Searches for those materials, chemical inertness, dielectric strength, and discharge breakdown found no passage addressing the claim in our copy. (LLM, conf=0.76)
Experimental — accuracy not yet measured
May combine two claims.
PremisecitationMany studies have shown that feedback stimulation has the potential to regain tactile and thermal sensation in amputees and improve their accuracy and confidence in manipulating prostheses, such as grasping objects.
“Many studies have shown that feedback stimulation has the potential to not only regain tactile and thermal sensation in amputees,[106,518] but also improve their accuracy and confidence in manipulating the prosthesis, such as grasping objects.[157,455]”
Quote in the paperSubstantial claim2 of 4 sources checkedMay combine two claims.
InterpretationcitationStimulation holds tremendous promise for prosthetic information feedback and rehabilitation.
“Stimulation holds tremendous promise for prosthetic information feedback[86,515] and rehabilitation.[329,516,517]”
Quote in the paperSubstantial claim1 of 5 sources checkedMay combine two claims.
PremisecitationOptogenetic stimulation is based on opsins that are light-sensitive and expressed only in certain cell types.
“Optogenetic stimulation is based on opsins that are sensitive to light signals and only expressed in certain types of cells.”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [555] source
May combine two claims.
PremisecitationBy genetically engineering opsins into target neurons and controlling light, these neurons can be activated or inhibited, which is important for sensory and motor recovery and rehabilitation.
“By genetically engineering these proteins into target neurons and controlling the light around them, these neurons can be activated or inhibited, which is particularly important for sensory and motor recovery and rehabilitation.[555]”
Quote in the paperSubstantial claim1 of 1 sources checked- cites [555] source
The Methods (AAV vectors; Optogenetic stimulation protocol, page unavailable) describe expressing channelrhodopsin-2 in targeted mouse neurons and manipulating them with light. The paper supports light-driven activation, but does not establish light-driven inhibition or a role in sensory and motor recovery or rehabilitation; its Discussion instead concerns amyloid reduction in mouse models. (LLM, conf=0.87)
Experimental — accuracy not yet measured
Probably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationSome Utah electrodes use flexible substrates to improve adaptability to complex surfaces.
“Some Utah electrodes also use flexible substrates to improve their adaptability to complex surface.[544]”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [544] source
The Materials and methods section describes an ECoG grid made from a silicone sheet with platinum electrodes, but does not identify it as a Utah electrode or say the sheet improves adaptability to complex surfaces. Searches for Utah electrodes and flexible substrates found no passage addressing that claim. (LLM, conf=0.75)
Experimental — accuracy not yet measured
May combine two claims.
PremisecitationThin film flexible electrical stimulators placed non-inserted on the cortical surface reduce brain tissue damage, but their array density is much smaller than penetrating microelectrodes, making them more suitable for stimulating relatively large brain areas.
“Although the second type, thin film flexible electrical stimulators, are available in non-inserted way on the cortical surface to reduce damage to brain tissue, the array density of such devices is much smaller than the first, and they are more suitable for stimulation of relatively large brain areas.[545,546]”
Quote in the paperNot a substantial claim1 of 2 sources checkedMay combine two claims.
PremisecitationMany studies have investigated the relationship between optogenetic stimulation and neurological disorders and control, including Parkinson's, Alzheimer's, spinal cord injuries, and somatosensory nociception, which relate to prosthetic control, feedback, and human movement rehabilitation.
“Many studies have delved into the relationship between optogenetic stimulation and neurological disorders and control, such as Parkinson's,[557] Alzheimer's,[558] spinal cord injuries,[559] and somatosensory nociception,[560,561] which have indistinguishable relationship with prosthetic control, feedback, and human movement rehabilitation.”
Quote in the paperNot a substantial claim2 of 3 sources checkedMay combine two claims.
PremisecitationSpinal cord stimulation can suppress pain and restore movement in paralyzed patients.
“Furthermore, stimulation of the spine can suppress pain and restore movement in paralyzed patients.[549]”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [549] source
The Results and discussion section (‘Stimulation of the distal stump to alleviate muscular atrophy’; page unavailable) reports improved motor function after stimulation of injured sciatic nerves in rats. It does not establish that spinal cord stimulation suppresses pain or restores movement in paralyzed patients. (LLM, conf=0.82)
Experimental — accuracy not yet measured
May combine two claims.
PremisecitationOptogenetic stimulation can both excite and inhibit nerve cells, whereas electrical stimulation only excites nerves.
“Furthermore, optogenetic stimulation can excite nerve cells and inhibit them, whereas electrical stimulation only excites nerves.[556]”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [556] source
The Introduction (page unavailable) says light activation of channelrhodopsin-2 can create action potentials in neurons, supporting the excitation part. The passages do not establish that optogenetic stimulation can inhibit nerve cells or that electrical stimulation only excites nerves. (LLM, conf=0.85)
Experimental — accuracy not yet measured
May combine two claims.
PremisecitationCombining hydrogels and conductive polymers is a hot research area because hydrogels have nerve-like mechanical properties and provide a hydrophilic interface that reduces non-specific protein adhesion.
“In addition, the combination of hydrogels and conductive polymers is a hot area of research since the former has mechanical properties similar to those of nerves and can provide a hydrophilic interface that reduces the adhesion of non-specific proteins.[58,539–542]”
Quote in the paperNot a substantial claim2 of 5 sources checked- cites [58] source
- cites [539] source
- cites [540] source
The Introduction describes conducting-polymer hydrogels as promising because their high water content resembles tissue, and the Discussion says the resulting gels can be tuned to mimic biological tissue at soft interfaces such as the brain. The paper does not specifically establish a match to nerve mechanics or say that a hydrophilic interface reduces nonspecific protein adhesion; searches for protein adsorption and adhesion found no supporting passage. Page numbers are unavailable in our copy. (LLM, conf=0.86)
Experimental — accuracy not yet measured - cites [541] source
The Introduction describes carbon-fiber arrays on polyimide, and the Discussion and Conclusion addresses their use as nerve electrodes. Searches for hydrogels, conductive polymers, hydrophilic interfaces, and non-specific protein adhesion found no passage addressing the attributed claim. (LLM, conf=0.75)
Experimental — accuracy not yet measured - cites [542] source
Probably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationAfferents and efferent projections from spinal grey matter carry somatosensory and motor information.
“Afferents and efferent projections from the spinal grey matter also carry somatosensory and motorial information.[515]”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [515] source
The Introduction discusses stimulation of peripheral nerves and motor units, while the Results describe nerve stimulation and muscle-state feedback. Searches for afferent and efferent projections and spinal grey matter found no passage in our copy describing the claimed sensory and motor pathways. (LLM, conf=0.73)
Experimental — accuracy not yet measured
May combine two claims.
PremisecitationBased on NFC data and power transmission, the device could be implanted over the mouse spinal cord minimally invasively without impeding movement.
“Based on NFC data and power transmission, the device could be implanted over the mouse spinal cord in a minimally invasive way without impeding movement of the mouse (Figure 15J).”
Quote in the paperSubstantial claim1 of 1 sources checked- cites [569] source
The Discussion (page unavailable) confirms NFC powering and communication. The Results and implantation methods (pages unavailable) describe a subcutaneous base station over the thoracic vertebral column, a cuff around the sciatic nerve, and no detected gait or coordination impairment compared with sham surgery. The paper does not report implanting the cuff over the spinal cord; it discusses spinal-cord placement only as a possible future adaptation. (LLM, conf=0.88)
Experimental — accuracy not yet measured
May combine two claims.
PremisecitationIn addition to haptic feedback, electrical stimulation is attractive for pain relief and sensory-motor control for prosthetics and orthotics.
“In addition to haptic feedback, electrical stimulation is also attractive pain relief and sensory-motor control for prosthetics and orthotics.[599,601]”
Quote in the paperNot a substantial claim2 of 2 sources checked- cites [599] source
The Introduction (page unavailable) says that TENS electrodes are used for pain relief and that electrotactile stimulation can provide sensory feedback relevant to controlling prosthetic devices. It does not address orthotics or establish electrical stimulation as a method of sensory-motor control for them. (LLM, conf=0.86)
Experimental — accuracy not yet measured - cites [601] source
The Results section (“Fully integrated ET system for augmented tactile sensations”; page unavailable) says the electro-tactile system could be applied to an artificial limb to give its user more information during operation. That supports a potential sensory-feedback application for prosthetics, but our copy does not describe pain relief, orthotics, or sensory-motor control beyond that proposed feedback. (LLM, conf=0.83)
Experimental — accuracy not yet measured
May combine two claims.
PremisecitationA radio frequency-based optogenetics device with μ-ILEDs and a photodetector operated successfully for up to four weeks, representing a novel stride into closed-loop wireless optogenetic modulation for clinical adoption.
“This radio frequency-based optogenetics device and its successful operation for up to four weeks represent a novel stride into closed-loop wireless optogenetic modulation for expediting the adoption of optogenetics technologies in clinical applications (Figure 15H).[566]”
Quote in the paperSubstantial claim1 of 1 sources checked- cites [566] source
The Results describe an RF-powered, single-µ-ILED spinal device and report robust operation for more than four weeks, although average in-vivo survival was nearly three weeks. The device layout does not include a photodetector, and the Discussion presents sensing and wireless data transmission as possible future adaptations, not demonstrated closed-loop operation. The paper does not establish clinical adoption. (LLM, conf=0.90)
Experimental — accuracy not yet measured
May combine two claims.
PremisecitationTo solve insufficient stimulation force, multi-layer stacking structures or hydraulic pressure to amplify force have been proposed.
“To solve the issue of insufficient stimulation force, multi-layer stacking structure,[592] or hydraulic pressure to amplify the force have been proposed.[63,593,594]”
Quote in the paperNot a substantial claim3 of 4 sources checked- cites [592] source
The cited paper discusses pneumatic actuators and notes that increasing air pressure increases fingertip force (5.1.1 Normal Indentation, p. 9). Its discussion of actuator choice (4.1 Form Factor, p. 6) does not address hydraulic pressure as a force-amplification method. Searches for hydraulic force amplification and multi-layer stacking found no passage supporting those proposed solutions. (LLM, conf=0.73)
Experimental — accuracy not yet measured - cites [63] source
- cites [593] source
The Introduction and Conclusion describe amplification of vibration in a polymer-film touch button, not amplification of stimulation force. Searches for hydraulic pressure and force-amplifying multilayer stacks found no supporting passage; the multilayer actuator listed in the References concerns low-voltage operation. (LLM, conf=0.76)
Experimental — accuracy not yet measured - cites [594] source
The device description and Methods describe a thin PZT actuator-and-sensor array, while Supplementary Figure S7 describes pressure induced by an actuator’s expansion. Searches for hydraulic force amplification and multilayer stacking found no passage proposing either approach to address insufficient stimulation force. The copy therefore does not verify the claim attributed to this source. (LLM, conf=0.73)
Experimental — accuracy not yet measured
May combine two claims.
PremisecitationOptogenetics was initially applied in rodent models to control brain neural circuits, but recent research shows promise for modulating spinal cord and peripheral nervous system activity.
“Optogenetics was initially applied in rodent models to control neural circuits in the brain, but recent research efforts have shown great promise in modulating the activity of the spinal cord and peripheral nervous system.[556]”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [556] source
The Results and conclusion (page numbers unavailable) show that light stimulation of ChR2-expressing spinal neurons in injured rats restored diaphragmatic activity, supporting the spinal-cord portion of the claim. The paper does not establish that optogenetics was initially applied to brain circuits in rodents or show modulation of peripheral nervous system activity; diaphragmatic muscle activity is an outcome, not evidence of direct peripheral nervous system modulation. (LLM, conf=0.86)
Experimental — accuracy not yet measured
May combine two claims.
PremisecitationThe parameters of applied current on the skin determine tactile stimulation comfort, and stimulation with a large current will induce muscle contractions.
“Moreover, in this demonstration, the facts that the parameters of the applied current on the skin determines the tactile stimulation comfort, and stimulation with a large current will induce muscle contractions were also verified.[599]”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [599] source
In the Application demonstration > Electrical stimulation section (page unavailable), the authors increased current to identify comfortable thresholds and stopped when stimulation became uncomfortable or caused muscle twitching. This supports a relationship between current amplitude and comfort, and shows twitching can occur, but it does not establish that a large current will always cause muscle contractions or test the effects of multiple current parameters on comfort. (LLM, conf=0.85)
Experimental — accuracy not yet measured
May combine two claims.
PremisecitationSubjects with force feedback were able to stop grasping at any desired level of gentle touch, while those without force feedback could not.
“The result illustrates that subjects with force feedback were able to stop grasping at any desired level of gentle touch, while those without force feedback cannot.”
Quote in the paperSubstantial claim1 of 1 sources checked- cites [599] source
The Application demonstration section measures electrotactile perception and comfort thresholds, while the Discussion and conclusion describes a proof of concept for reusable electrodes. Neither reports a grasping experiment comparing subjects with and without force feedback; searches for stopping grasping at a desired gentle-touch level and for a feedback-versus-no-feedback comparison found no such result in our copy. (LLM, conf=0.75)
Experimental — accuracy not yet measured
May combine two claims.
PremisecitationElectrical stimulation roughly includes two types: voltage control, which can reduce skin burn feeling during stimulation, and current control, which is relatively insensitive to differences in skin interface features.
“Electrical stimulation roughly includes two types, one with voltage control, which is capable of reducing skin burns feeling during stimulation, and the other with current control, which is relatively insensitive to differences in the feature of the skin interface.[360,599,600]”
Quote in the paperNot a substantial claim3 of 3 sources checked- cites [360] source
The Electro-tactile stimulation section describes voltage- and current-regulated stimulation and says changes in interface impedance and load might not affect the current under current regulation. It says voltage regulation can minimize the chance of skin burns, not the feeling of burning during stimulation. Its two-type distinction is also specific to electro-tactile stimulation rather than electrical stimulation generally. (LLM, conf=0.86)
Experimental — accuracy not yet measured - cites [599] source
The Application demonstration > Electrical stimulation section (page unavailable) reports using a constant-current stimulator, supporting the existence of current-controlled stimulation. It does not compare current and voltage control, say that voltage control reduces skin-burn sensations, or establish that current control is relatively insensitive to skin-interface differences. (LLM, conf=0.78)
Experimental — accuracy not yet measured - cites [600] source
The Results section on network hubs and the Discussion address brain-network findings in children with epilepsy, not electrical stimulation. Searches for voltage control, current control, skin burns, and skin-interface features found no passage addressing the claim in our copy; no page numbers were provided. (LLM, conf=0.78)
Experimental — accuracy not yet measured
May combine two claims.
PremisecitationFor human-device interfaces, macro interface problems include large conformal attachment of prosthetic skin, sweat trap between wearable sensor and skin, and fixation of neural implants.
“For example, the large conformal attachment of prosthetic skin,[149] sweat trap between the wearable sensor and the skin,[75] and fixation of neural implants.[420]”
Quote in the paperNot a substantial claim3 of 3 sources checked- cites [149] source
The cited paper supports the part of the sentence concerning large-area, conformable attachment: Related Work (p. 1) discusses skin modules covering robot surfaces, and “Mounting and Covering Robot Surfaces With Robot Skin” (p. 5) describes fastening skin patches to a robot. It does not establish the claimed problem for prosthetic skin attached at a human-device interface. The sweat-trap and neural-implant examples have separate citations and are not judged here. (LLM, conf=0.83)
Experimental — accuracy not yet measured - cites [75] sourceExperimental — accuracy not yet measured
- cites [420] source
The citation [420] is attached to the fixation of neural implants, not the preceding examples of prosthetic skin or wearable sensors. The Introduction (p. 2) discusses neural coding as a communication channel, and the Results (p. 14) discuss synthetic tests of that method. A search for implant fixation and related terms found no passage in our copy addressing the claimed interface problem. (LLM, conf=0.76)
Experimental — accuracy not yet measured
Probably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationSome prospective systematic works have been reported.
“Promisingly, some prospective systematic works have been reported.[76,153]”
Quote in the paperNot a substantial claim1 of 2 sources checkedMay combine two claims.
PremisereasoningBiofuel cells, piezoelectric, triboelectric, solar and other self-powered methods are prominent representatives of power supply for low-energy devices, truly enabling the user to move freely.
“biofuel cells,[615] piezoelectric,[122] triboelectric,[127] solar[616] and other self-powered methods are prominent representatives of power supply for low-energy devices, truly enabling the user to move freely.”
Quote in the paperNot a substantial claim1 of 3 sources checked- cites [615] source
- cites [122] source
- cites [127] source
The Results (Structure and working mechanism; page unavailable) show that the paper’s textile sensor generates an electrical signal through triboelectrification, supporting the citation’s triboelectric example. The paper does not show that this sensor supplies power to another low-energy device or that it enables unrestricted movement; its Results note that motion can affect pulse signals. (LLM, conf=0.84)
Experimental — accuracy not yet measured
May combine two claims.
PremisecitationOn-body testing showed that after 15 minutes of training, an amputee could use the flexible prosthetic system to perform a range of precise gripping and social tasks, demonstrating potential for future applications.
“The on-body test of this system showed excellent results: after 15 minutes of training, the amputee was able to use the flexible prosthetic system to perform a range of precise gripping and social tasks, demonstrating tremendous potential for future applications.[76]”
Quote in the paperSubstantial claim1 of 1 sources checked- cites [76] source
May combine two claims.
PremisecitationA soft EMG controlled pneumatic neuroprosthetic with ionic capacitive sensors and flexible stimulators was developed to reduce manufacturing costs and achieve lightweight actuation.
“As an exemplary case, a soft EMG controlled pneumatic neuroprosthetic with ionic capacitive sensors and flexible stimulators was developed to reduce manufacturing costs and achieve lightweight actuation.”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [76] source
The Abstract and Conclusion describe a lightweight, potentially low-cost, pneumatically actuated hand controlled by EMG signals. The Design section describes ionic hydrogel-elastomer capacitive touch sensors and electrical stimulators, but does not say the stimulators are flexible. (LLM, conf=0.88)
Experimental — accuracy not yet measured
May combine two claims.
PremisecitationSome integrated work can enhance space utilization, reduce manufacturing costs, and achieve in-situ information sensing, processing, and actuating simultaneously for more accurate therapy.
“Currently, some integrated work can enhance space utilization,[599] reduce manufacturing costs,[155] and achieve in-situ information sensing, processing, and actuating simultaneously for more accurate therapy.[548,605]”
Quote in the paperNot a substantial claim1 of 4 sources checked- cites [599] source
The Introduction describes the paper’s electrode as low-cost, and “Environmental and financial cost” reports a $0.45 material cost per electrode and potential savings from reuse. It does not establish that integration reduces manufacturing costs; its comparison concerns long-term use versus disposable electrodes, and it excludes equipment costs. The paper does not report simultaneous in-situ sensing, processing, and actuation for therapy. (LLM, conf=0.82)
Experimental — accuracy not yet measured - cites [155] source
- cites [548] source
- cites [605] source
Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
InterpretationcitationIn a system, these devices can work independently, but ideally each part can form a closed-loop system that is interlinked to perform more precise and complex tasks.
“In a system, they can work independently, but, ideally, each part can form a closed-loop system that is interlinked to perform more precise and complex tasks.[76,153]”
Quote in the paperNot a substantial claim1 of 2 sources checked- cites [76] source
The Design section (page unavailable) describes an interlinked system: EMG control, touch sensors and electrical stimulation let the user adjust the hand’s grasp in a closed loop. It says the hand’s degrees of freedom can be independently controlled, but does not establish that the devices work independently, that each part forms its own closed loop, or that this arrangement enables more precise and complex tasks. (LLM, conf=0.84)
Experimental — accuracy not yet measured - cites [153] source
Probably not a substantial claim: may not pass S3 (load-bearing), S4 (based).
Findingnone givenThe annual number of PubMed articles containing the keyword 'rehabilitation robotics' increased from 191 in 2010 to 772 in 2020.
“with the keyword “rehabilitation robotics” in PubMed’s annual academic articles skyrocketing from 191 to 772 papers in 2010 and 2020 respectively.”
Quote in the paperNot a substantial claimMay combine two claims.
Findingown dataA single-unit planar HASEL actuator lifted a 4 kg object at 69% linear actuation strain, verifying its linear actuating ability.
“To verify the linear actuating ability of a single-unit planar HASEL actuator, a 4kg object lifting experiment at 69% linear actuation strain was exhibited (Figure 12H).”
Quote in the paperSubstantial claimProbably not a substantial claim: may not pass S1 (asserted), S3 (load-bearing), S4 (based).
Interpretationnone givenPneumatic and tendon actuation are currently the most suitable forms of wearable rehabilitation in soft robots.
“Because of this, pneumatic and tendon-actuation are currently the most suitable forms of wearable rehabilitation in soft robots.”
Quote in the paperNot a substantial claimMay combine two claims.
PremisecitationPorous structures have high stretchability and breathability, facilitating conformal and comfortable attachment to skin.
“Generally, porous structures have a high stretchability and breathability (See Figure 3G and 3H), which can facilitate conformal and comfortable attachment to the skin.[73]”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [73] source
May combine two claims.
PremisecitationSoft robotic materials need to withstand rapid exposure to extreme temperatures, toxic chemicals, and continuous deformations and elongations to replace metal designs.
“To replace the current metal designs, soft robotic materials therefore require the ability to withstand rapid exposure to extreme temperatures and toxic chemicals as well as continuous deformations and elongations.[38]”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [38] source
Probably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationGuided exercises performed over long periods significantly improve recovery of lost brain function and mobility.
“In the late 20th century, researchers found that over long periods of time guided exercises had a significant improvement in restoring lost brain function and mobility.[14]”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [14]
Probably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationThe first tangible use of e-skin for prosthetics was in 1974, when minor sensory feedback was incorporated onto a robotic arm.
“Initially proposed in science fiction movies, the first tangible application of e-skin for prosthetics occurred in 1974 with minor sensory feedback incorporated onto a robotic arm.[26]”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [26]
May combine two claims.
PremisecitationSelf-healing can be achieved by leveraging bonding properties of relevant materials, while biodegradability is mainly achieved by using inherently unstable materials.
“In addition, self-healing can be achieved by leveraging the bonding properties of the relevant materials,[67] while biodegradability is mainly achieved by using inherently unstable materials.[68,69]”
Quote in the paperNot a substantial claim0 of 3 sources checkedMay combine two claims.
PremisecitationDespite improvements and a $6.39 billion market, up to 40% of patients with limb impairment still decline artificial replacements.
“Despite the recent improvements to the material, design, and functionality of medical robotics, as well a $6.39 billion dollars market,[23] up to 40% of limb impairment patients still option out of using artificial replacements.[19]”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [19] source
May combine two claims.
PremisereasoningConductive polymers and hydrogels have considerable charge storage and injection capabilities and are commonly used in electrostimulation electrodes, electrophysiological recording electrodes, and nano-percolation networks.
“As an example, conductive polymers and hydrogels have considerable charge storage and injection capabilities. Because of this, they are commonly used in electrostimulation electrodes,[58] electrophysiological recording electrodes, and nano-percolation networks that maintain statistical stability of impedance under deformation conditions.[44,60]”
Quote in the paperNot a substantial claim0 of 3 sources checkedProbably not a substantial claim: may not pass S2 (checkable), S3 (load-bearing).
PremisecitationThe chemical composition of flexible devices should adapt to biochemical environments such as sweat and interstitial fluid to ensure user safety and prevent device failure.
“The chemical composition of flexible devices should be adaptable to various biochemical environments (biofluids like sweat and interstitial fluid) to ensure user safety and prevent device failure, especially in biological fluids containing various erosive ions and attacking immune cells.[50]”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [50] source
May combine two claims.
Premisenone givenBending strains decrease linearly with thickness, so inherently inelastic materials become flexible when made into ultrathin films or wires.
“Bending strains decrease linearly with thickness, making inherently inelastic materials flexible when fabricated into ultrathin films or wires (on the nanometers/micrometers scale).”
Quote in the paperSubstantial claimMay combine two claims.
PremisecitationProper conformability can reduce damage to the device and body during tissue displacement and motion artifacts while improving patient comfort and outcome.
“Proper conformability can reduce damage to the device and body during tissue displacement and motion artifacts while also improving patient comfort and outcome.[39]”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [39] source
May combine two claims.
PremisecitationThe commonly cited reasons for declining artificial replacements are unnatural feel, poor functionality, and heavy device weight.
“The common issues cited are the unnatural feel, poor functionality, and heavy weight of the device.[19]”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [19] source
May combine two claims.
InterpretationcitationE-skin sensing can achieve autonomous electronic rehabilitation by monitoring the patient in real time, offering a promising solution for personalized rehabilitation.
“In such scenarios, e-skin sensing can achieve autonomous electronic rehabilitation by monitoring the patient in real-time, providing a promising solution for the development of personalized rehabilitation science.[93,94]”
Quote in the paperSubstantial claim0 of 2 sources checkedMay combine two claims.
PremisecitationResistive sensors are limited by large hysteresis, confounding temperature sensitivity, and varying pressure sensitivity.
“Nevertheless, some drawbacks, like large hysteresis,[116] large confounding temperature sensitivity,[117] and varying pressure sensitivity[118] have limited the performance of resistive sensors.”
Quote in the paperNot a substantial claim0 of 3 sources checkedMay combine two claims.
PremisecitationPiezoelectric and triboelectric sensors have unique advantages in dynamic force measurements, including high-frequency measurement and self-power supply.
“Piezoelectric and triboelectric have their unique advantages in dynamic force measurements, i.e. high-frequency measurement, and self-power supply.[121–123]”
Quote in the paperNot a substantial claim0 of 3 sources checkedMay combine two claims.
PremisecitationIn rehabilitation, lack of supervision may lead to incorrect patient posture, reducing rehabilitation efficiency and potentially aggravating disability.
“In rehabilitation, the absence of supervision may lead to incorrect patient posture, which reduces the efficiency of rehabilitation and can even aggravate a disability.[88]”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [88] source
Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
PremisecitationPiezoelectric and triboelectric strain sensors are two other major types of stretchable strain sensors.
“Piezoelectric and triboelectric strain sensors are two other major types of stretchable strain sensors.[180–182]”
Quote in the paperNot a substantial claim0 of 3 sources checkedMay combine two claims.
PremisecitationPiezoelectric and triboelectric sensing mechanisms have major drawbacks of unreliable static sensing and drift in long-term measurements.
“Nonetheless, the major drawbacks of these two sensing mechanisms are the unreliable static sensing performances and drift in long-term measurements.[108]”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [108] source
Probably not a substantial claim: may not pass S3 (load-bearing), S4 (based).
Interpretationnone givenManufacturing precision and integration density of flexible devices are still in their infancy compared with rigid devices.
“Compared to rigid devices, the manufacturing precision and integration density of flexible devices are still in their infancy.”
Quote in the paperNot a substantial claimMay combine two claims.
PremisecitationAt the current stage, e-skin can mimic or surpass human skin in mechanical and thermal sensing and in chemical, physiological, and proximity sensing functionalities.
“At the current stage, e-skin can mimic or surpass human skin performance in mechanical and thermal sensing (as shown in Table 1) and functionalities in terms of various chemical,[91] physiological, and proximity sensing[92] to deliver accurate and diversified information to users.”
Quote in the paperSubstantial claim0 of 2 sources checkedProbably not a substantial claim: may not pass S3 (load-bearing), S4 (based). May combine two claims.
Interpretationnone givenManufacturing cost of materials and structures is key in determining device price, and many materials are costly for proof of concept in the lab.
“The manufacturing cost of materials and structures is the key in determining the device’s price. Many materials and structures are already costly for proof of concept in the lab.”
Quote in the paperNot a substantial claimMay combine two claims.
PremisecitationThermal perception for prosthetics can complement pressure sensing to extract more tactile information, inform the amputee about the environment thermographically, and prevent danger or device failure from extreme heat or cold.
“Thermal perception for prosthetics can complement pressure sensing for extracting more tactile information from the environment, which not only informs the amputee about the environment thermographically, but can also prevents the user from danger or potential device failure due to extreme heat or cool.[220,221]”
Quote in the paperSubstantial claim0 of 2 sources checkedMay combine two claims.
PremisereasoningSimultaneous detection of thermal and mechanical signals is challenging due to coupling but is possible.
“Simultaneous detection of thermal and mechanical signals is challenging due to the coupling problem; however, it is possible.”
Quote in the paperNot a substantial claimMay combine two claims.
PremisecitationThe device was made with biodegradable materials, avoiding the need for surgical extraction.
“This device was fabricated with biodegradable materials, which avoids the need for surgical extraction.[204]”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [204] source
Probably not a substantial claim: may not pass S4 (based).
Premisenone givenMeasuring strain from small muscle deformations requires high sensitivity.
“Unlike large strain measurements of joint angles, measuring the strain from small muscle deformations requires a high sensitivity.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationThe bend angle of a foam integrated with robotic skin was calculated from device dimensions and electrical signals.
“As shown in Figure 6C, to demonstrate the proprioceptive ability, the bend angle of a foam integrated with the robotic skin was calculated from the dimension of the device and the electrical signals.[200]”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [200] source
May combine two claims.
Premisenone givenPlacing sensors on different parts or integrating them on one substrate cannot intrinsically measure two signals simultaneously at one point, wasting space at key locations like fingertips.
“Nonetheless, both types mentioned above cannot intrinsically measure two signals simultaneously at one point, resulting in a waste of valuable space at key locations (like fingertips).”
Quote in the paperSubstantial claimMay combine two claims.
PremisecitationSoft actuators lack the ability to reflect movements because of their continuous motion, which makes flexible strain sensors attractive for soft actuators.
“Soft actuators lack this ability because of their continuous mode of motion, making the application of flexible strain sensors on soft actuators extremely attractive.[37,198,199]”
Quote in the paperSubstantial claim0 of 3 sources checkedMay combine two claims.
PremisecitationOptical temperature sensors using IR thermography and colorimetric thermochromic liquid crystals can record temperature more intuitively and have been applied to measure human body temperature.
“Moreover, some optical temperature sensors use infrared (IR) thermography[218] and colorimetric techniques with thermochromic liquid crystals that can be used to record the temperature more intuitively[219] and have already been applied to measure the temperature of the human body.”
Quote in the paperNot a substantial claim0 of 2 sources checkedMay combine two claims.
InterpretationreasoningProviding real-time monitoring of human motions and physiological signatures provides rich data for disability rehabilitation and supports personalized rehabilitation strategies.
“Providing real-time monitoring of human motions and physiological signatures provides rich data for the field of disability rehabilitation, which is conducive to the formulation of personalized rehabilitation strategies to achieve better rehabilitation results.”
Quote in the paperSubstantial claimProbably not a substantial claim: may not pass S3 (load-bearing), S4 (based).
Premisenone givenMeasuring pressure and temperature in a single parameter is a potential solution that is more efficient for data collection.
“Another potential solution is to measure pressure and temperature in a single parameter, which is more efficient data collection.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S4 (based).
Premisenone givenElectrophysiological signals carry a wealth of information about the human body.
“Electrophysiological signals carry a wealth of information about the human body.”
Quote in the paperNot a substantial claimMay combine two claims.
PremisecitationHuman skin has receptors for mechanical and thermal information but no specific humidity receptors; the brain perceives wetness indirectly by analyzing mechanical and thermal information.
“While the skin has receptors for sensing mechanical and thermal information, there are no specific receptors that sense humidity. Rather, the human brain is able to”
Quote in the paperNot a substantial claim0 of 2 sources checkedProbably not a substantial claim: may not pass S3 (load-bearing).
Premisenone givenOrganic flexible LEDs and photodiodes are driving PPG application in wearables.
“As an example, organic flexible LEDs and photodiodes are driving the application of photoplethysmogram (PPG) in the wearable sector.”
Quote in the paperNot a substantial claimMay combine two claims.
PremisecitationIn that e-skin, charge relaxation time of capacitance is a strain-insensitive feature for absolute temperature, and normalized capacitance is a temperature-insensitive extrinsic feature for strain.
“where two variables (temperature and strain) are derived from analyzing the ion relaxation dynamics: the charge relaxation time of the capacitance as a strain-insensitive feature to measure absolute temperature, and the normalized capacitance as a temperature-insensitive extrinsic feature to measure strain.”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [230] source
May combine two claims.
PremisecitationElectrochemical methods are attractive due to high sensitivity, low response time, and long-term stability.
“Electrochemical methods are attractive due to their high sensitivity, low response time, and long-term stability.[232]”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [232] source
Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
Premisenone givenColorimetric optical methods have simple principle and structure but are more difficult to make highly sensitive.
“One is based on the colorimetric method, whose principle and structure are simple, but more difficult to reach high sensitivity.”
Quote in the paperNot a substantial claimMay combine two claims.
InterpretationreasoningIntegrating in-situ sensing, on-site processing, and data transmission allows chemical sensing platforms to achieve continuous, real-time sensing of ions and metabolites, which is crucial for comprehensive knowledge of a wearer's well-being.
“Integrating in-situ sensing, on-site processing, and data transmission together, chemical sensing platforms can achieve the goal of continuous, real-time sensing of ions and metabolites, which is crucial to obtain more comprehensive knowledge about a wearer’s well-being.”
Quote in the paperSubstantial claimProbably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
Premisenone givenFabrication of large-area e-skins is challenging; most existing flexible sensor research is miniaturized proof-of-concept.
“Secondly, fabrication of large area e-skins is challenging. Most of the existing research on flexible sensors are miniaturized proof-of-concept.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S4 (based). May combine two claims.
Premisenone givenUltra-thin e-skins have better mechanical compliance, but their mechanical strength decreases significantly with thickness.
“Normally, ultra-thin e-skins have better mechanical compliance, but their mechanical strength decreases significantly with their thickness.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
Premisenone givenThe environment contains enormous quantities and types of chemicals, and rapid accurate identification could provide essential environmental information.
“However, there are enormous quantities and types of chemicals in the environment (e.g., gases, food, toxins, etc.), where rapid and accurate identification of these substances could provide the user with essential information about the environment.”
Quote in the paperNot a substantial claimMay combine two claims.
PremisereasoningSuch cross-sensor mechanisms for wetness perception may require intelligent algorithms and are not available in current e-skin.
“Such mechanisms, which may require intelligent cross-sensor algorithms, are not available in the current e-skin.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S4 (based).
Premisenone givenIn many cases, the sensing capabilities of pressure, strain, temperature, and chemical sensors have surpassed human skin in function and performance.
“In many cases, the sensing capabilities of each have surpassed human skin in terms of function and performance, which is crucial for the development of artificial limbs with the same or better sensory function as human limbs.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
PremisecitationFluorescence methods, where emitted light has a larger wavelength than received light, are more sensitive and suitable for trace substance measurement.
“The last method is the fluorescence approach, where the wavelength of the light emitted is larger than the wavelength received, which is more sensitive and suitable for trace substance measurement.[238]”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [238] source
May combine two claims.
Premisenone givenHuman skin lacks accurate chemical sensing capabilities and instead uses mechanoreceptors to sense chemical contact and nociceptors to perceive chemical damage.
“From a bionic perspective, human skin does not have accurate chemical sensing capabilities, but rather uses mechanoreceptors to sense chemical contact and nociceptors to perceive chemical damage.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing), S4 (based).
Premisenone givenPrinciples of bionics have not been fully developed and applied to electronic skin, such as moisture detection.
“Thirdly, the principles of bionics have not been fully developed and applied to electronic skin, like moisture detection.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
Premisenone givenLarge-area fabrication must comply with conformal design from 2D to 3D, signal crosstalk handling, self-healing, and low preparation costs.
“Large-area fabrication must still comply with conformal design from 2D to 3D, signal crosstalk handling, the self-healing requirement, as well as the low preparation costs (time and money).”
Quote in the paperNot a substantial claimMay combine two claims.
PremisecitationUsing machine learning to directly analyze coupled multimodal data allows cross-reactive devices to achieve a certain degree of decoupling and greatly reduces sensor mechanism and structure complexity.
“Utilizing machine learning methods to directly analyze the coupled multimodal data, these devices can achieve a certain degree of decoupling. This approach greatly reduces the complexity of the sensor mechanism and structure.[231]”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [231] source
Probably not a substantial claim: may not pass S2 (checkable), S3 (load-bearing), S4 (based).
Interpretationnone givenChemical and biomolecular information collected by e-skin from the human body could benefit the design of next-generation HMI for personalized robotic rehabilitation.
“Furthermore, the chemical and biomolecular information collected by the e-skin from the human body could greatly benefit the design of next-generation HMI toward personalized robotic rehabilitation.”
Quote in the paperNot a substantial claimMay combine two claims.
PremisecitationBecause brain recorders directly interface with the brain, they circumvent communication and control channels in peripheral nerves and muscles, which is significant for patients with damaged peripheral nervous systems or severe spinal cord injuries.
“Beyond these, as the recorders directly interface with the brain, they circumvent the communication and control channels in peripheral nerves and muscles, which is of great significance for patients with damaged peripheral nervous systems or other severe spinal cord injuries.[335]”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [335] source
Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
Premisenone givenNon-invasive electrophysiological recording is widely accepted and can be extracted on the skin surface.
“Non-invasive electrophysiological recording is also widely accepted and can be extracted on the skin’s surface.”
Quote in the paperNot a substantial claimMay combine two claims.
PremisecitationECG captured via invasive and wearable devices cannot be used for prosthetic control but provides auxiliary information for disability rehabilitation monitoring.
“Another popular detection technique for electrophysiological signals captured via invasive and wearable devices is electrocardiogram (ECG),[288,289] which cannot be used for prosthetic control, but does provide auxiliary information for disability rehabilitation monitoring.”
Quote in the paperNot a substantial claim0 of 2 sources checkedMay combine two claims.
PremisecitationRecent studies have demonstrated the feasibility of piezoelectric, NFC, and ultrasonic technologies for power supply and data transmission.
“Specifically, recent studies have demonstrated the feasibility of piezoelectric,[327] near field communication (NFC),[328] and ultrasonic technologies[329] in power supply and data transmission.”
Quote in the paperNot a substantial claim0 of 3 sources checkedMay combine two claims.
Premisenone givenLFP recorders mostly use microelectrodes that penetrate directly into the cerebral cortex, capturing more accurate and deeper brain signals.
“LFP recorders mostly use microelectrodes to penetrate directly into the cerebral cortex, which capture more accurate and deeper brain signals.”
Quote in the paperNot a substantial claimMay combine two claims.
PremisecitationNon-invasive electrophysiological sensors are more extensively researched and generally preferred by many patients.
“Of the two, non-invasive sensors are more extensively researched and is generally preferred by many patients.”
Quote in the paperNot a substantial claim0 of 3 sources checkedProbably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationInvasive recording routinely uses peripheral in vivo tissues with ENG and EMG to record peripheral nerve activity and muscle electrical signals.
“Invasive recording techniques routinely use peripheral in vivo tissues with electroneurography (ENG)[277,278] and electromyography (EMG),[279,280] which can record peripheral nerve activity and muscle electrical signals respectively.”
Quote in the paperNot a substantial claim0 of 4 sources checkedProbably not a substantial claim: may not pass S2 (checkable).
PremisereasoningBecause surgery damages the body, fully implantable non-removable devices should operate for a long period, ideally a full human lifetime, to avoid frequent battery-replacement surgery.
“Moreover, given the damage of the surgery to the human body, fully implantable non-removable devices should be operational for a long period of time (ideally lasting a full human lifetime) to avoid the surgery associated with frequent battery replacement.”
Quote in the paperNot a substantial claimMay combine two claims.
PremisereasoningNon-invasive electrophysiological recording techniques are more common than invasive procedures because their convenience and safety relieve users from surgery risk.
“Non-invasive electrophysiological recording techniques are more common than invasive procedures as their convenience and safety can relieve users from the risk of surgery.”
Quote in the paperNot a substantial claimMay combine two claims.
PremisecitationOn-site signal processing is beneficial to reduce loss of sensing information, filter noise, improve transmission efficiency, and enable full portability.
“In this signal loop, on-site signal processing is beneficial to reduce the loss of sensing information and filter noise as well as improve the transmission efficiency and enable the system to be fully portable.[416]”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [416] source
Probably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationThe primary function of the somatosensory nervous system is to act as a communication pathway between environmental bodies and perception.
“The primary function of the somatosensory nervous system is to act as a communication pathway between environmental bodies and our perception of the world.[421]”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [421] source
May combine two claims.
InterpretationreasoningThe microscopic size of neural dust opens up the possibility of injectable implantation, greatly reducing difficulty and expense.
“The microscopic size of these “dust” also opens up the possibility of injectable implantation, which greatly reduces the difficulty and expense of implantation.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
Premisenone givenImplantable electrodes are more specialized and require special structures to adapt to in vivo tissues, while epidermal recordings tend to be universal.
“However, implantable electrodes are more specialized and require special structures to adapt to in vivo tissues, while in contrast, electrical recordings from epidermal electrodes tend to be universal.”
Quote in the paperNot a substantial claimMay combine two claims.
Premisenone givenProper encapsulation minimizes rejection by the body and prevents body fluid from eroding the device.
“A proper encapsulation ensures, on the one hand, that rejection by the body is minimized and, on the other hand, that the body fluid environment does not erode the device.”
Quote in the paperNot a substantial claimMay combine two claims.
PremisecitationImplantable EMG has advantages over surface EMG: higher signal quality, less movement artifacts, and ability to record small and deep muscle activity.
“In contrast to surface EMG, implantable EMG has many advantages, such as higher signal quality, less movement artifacts, and the ability to record small and deep muscle activity.[364]”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [364] source
May combine two claims.
PremisecitationPPG is a potential alternative monitoring solution for ECG, as it obtains superficial vascular information through infrared optical signals while being placed comfortably around the finger, ear, or forehead in a non-contact way.
“In recent years, the rapid emergence of PPG is a potential alternative monitoring solution for ECG, as it can obtain superficial vascular information through infrared optical signals, while being placed comfortably around the finger, ear, or forehead in a non-contact way.[268]”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [268]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
May combine two claims.
PremisecitationFloating movement of the device in the body environment leads to failure of the record, and even infection and life danger.
“The floating movement of the device in the body environment will directly lead to the failure of the record, and even cause infection, resulting in life danger.”
Quote in the paperSubstantial claimMay combine two claims.
PremisecitationDue to low Young's modulus and excellent stretchability, flexible electrodes form a relatively stable combination with skin, reducing contact impedance and increasing SNR by reducing movement artifacts.
“Due to its low Young's modulus and excellent stretchability, the flexible electrode can form a relatively stable combination with the skin, which can effectively reduce the contact impedance in measurement and increase the SNR (by reducing movement artifacts).[93]”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [93] source
May combine two claims.
PremisecitationEEG is the most common brain signal in clinical applications and has been widely utilized in prosthetics and other HMI applications.
“As the most common brain signal in clinical applications, EEG has been widely utilized in prosthetics and other HMI applications.[285,399]”
Quote in the paperNot a substantial claim0 of 2 sources checkedProbably not a substantial claim: may not pass S3 (load-bearing), S4 (based). May combine two claims.
InterpretationreasoningThe heartbeat is an autonomic response without intentional control, so ECG signals cannot be applied to control prosthetics.
“In fact, the heartbeat is an autonomic response without intend control, thus, ECG signals cannot be applied to control prosthetics.”
Quote in the paperNot a substantial claimMay combine two claims.
PremisecitationIn electrocutaneous stimulation for grip intensity, amplitude modulation is the most important parameter for accurate association and comprehension, but it is susceptible to sensation adaptations.
“In electrocutaneous stimulation for grip intensity, amplitude modulation is the most important parameter for accurate association and comprehension of the received stimuli; however, amplitude modulation is also known to be susceptible to sensation adaptations.[431]”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [431] source
Probably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationThe soft and stretchable skeletal muscles, including muscle bellies and tendons, are the natural mechanical actuators in the human body.
“The inherently soft and stretchable skeletal muscles, including the muscle bellies and tendons, are the natural mechanical actuators in the human body.[452]”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [452] source
Probably not a substantial claim: may not pass S3 (load-bearing).
PremisereasoningIn practice, convolutional neural networks use multiple filters to extract different key features from an image.
“In practice, CNNs use multiple filters to extract different key features within a photo.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S4 (based).
Interpretationnone givenCommunicating external sensory information to a patient is an important step in establishing a connection between the user and their phantom limb.
“Communicating external sensory information to a patient is an important step in establishing a connection between the user and their phantom limb.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing), S4 (based). May combine two claims.
Interpretationnone givenMachine learning and other neuromorphic architectures can speed up processing time, which is currently limited by electronic interference and the von Neumann bottleneck.
“ML and other neuromorphic architectures offer a way to speed up this processing time, which is currently limited by electronic interference and the von Neumann bottleneck.”
Quote in the paperNot a substantial claimClassified as probably not a substantial claim. May combine two claims.
InterpretationreasoningAdvancing communication channels in rehabilitation robotics and prosthetics can allow medical robotics to be fully integrated into the user's daily routine and increase user acceptance of therapeutic technologies.
“Through advancing communication channels in rehabilitation robotics and prosthetics, medical robotics can be fully integrated into the user’s daily routine, allowing for higher user acceptance of many therapeutic technologies.”
Quote in the paperSubstantial claimClassified as probably not a substantial claim.
InterpretationcitationMachine learning applications in medical robotics need to account for racial, gender, sexuality, and age factors to prevent algorithms from finding a local optimum that overfits the majority population while underperforming on minority groups.
“Recognizing that there is a racial, gender, sexuality, and age component in medical data reaffirms the need to account for such factors in ML applications in medical robotics to prevent the algorithm from finding a local optimum that overfits the majority of the population while underperforming on minority groups.[449,451]”
Quote in the paperSubstantial claim0 of 2 sources checkedProbably not a substantial claim: may not pass S3 (load-bearing).
Premisenone givenSupport vector machines and k-nearest neighbors classify data by first grouping points into different subcategories, unlike convolutional neural networks.
“Unlike convolutional neural networks, the support vector machine and k-nearest neighbor algorithms classify data by first grouping the points into different subcategories.”
Quote in the paperNot a substantial claimClassified as probably not a substantial claim.
PremisereasoningMuch of the data needs preprocessing to extract useful features in the correct format.
“Much of the data needs preprocessing to first extract useful features in the correct format.”
Quote in the paperSubstantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
Premisenone givenSupport vector machines segment space by defining a boundary plane that maximally separates the greatest number of similar points, focusing on edge points at the boundary.
“Support vector machines segment the space by defining a boundary plane to maximally separate the greatest number of similar points (specifically focusing on the edge points at the boundary).”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationConvolutional neural networks extract information from images by classifying features within them.
“Convolutional neural networks are used for extracting information from photos by interpreting (classifying) different features inside an image.[443]”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [443] source
Probably not a substantial claim: may not pass S3 (load-bearing).
InterpretationreasoningThe inability to formally predict whether machine learning will improve accuracy on a dataset beforehand partly comes from the possibility of bad and misused data in input samples.
“The inability to formally postulate whether ML will enhance the accuracy in a dataset beforehand partly stems from the possibility of bad and misused data present in the input samples.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing), S4 (based). May combine two claims.
Interpretationnone givenMachine learning in data communication can improve accuracy and reduce the amount of sensory data required by revealing hidden overlapping features.
“Artificial intelligence (AI), specifically machine learning (ML), in data communication can enhance the accuracy and reduce the volume of sensory information needed, uncovering hidden – possibly overlapping – features present in the data.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationThrough joint leverage, changes in muscle length and tension are translated into rotational movements and forces.
“Through the leverage of joints, changes in length and tension of the muscles are translated into rotational movements and forces.[453]”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [453] source
Probably not a substantial claim: may not pass S3 (load-bearing), S4 (based). May combine two claims.
Premisenone givenEEG, EMG, and ECG data produce a semi-continuous flow of points, most of which are irrelevant or hidden by noise.
“For example, EEG, EMG, and ECG data outputs a semi-continuous flow of points, most of which are not relevant or hidden by noise.”
Quote in the paperNot a substantial claimMay combine two claims.
PremisecitationWhen trained across the whole population, machine learning models preferentially mislabel people from minority groups, but when applied to each individual subgroup the models maintain high accuracy.
“In practice, when trained across the whole population, ML models preferentially mislabel people from minority groups, but when applied to each individual subgroup the models maintains their high accuracy.[451]”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [451] source
Probably not a substantial claim: may not pass S3 (load-bearing), S4 (based).
Premisenone givenThe most common supervised learning modules are convolutional neural networks, support vector machines, k-nearest neighbors, and artificial neural networks.
“the most common being convolutional neural networks (CNN), support vector machines (SVM), k-nearest neighbors (KNN), and artificial neural networks (ANN).”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing), S4 (based).
Premisenone givenThere are two main routes for relaying sensory feedback information: invasive contact with the nervous system and external stimulation of the user's limb.
“There are two main routes researchers can take in relaying sensory feedback information: invasive contact with the nervous system and external stimulating the user’s limb.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
Premisenone givenIf input features cannot be well separated into groups, a kernel function can remap the data into a higher dimension where boundary lines can section off information more easily.
“If the input points (the features) cannot be well separated into different groups, one can further apply a kernel function to remap the data into a higher dimension where it is easier for boundary lines to section off the information.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationDown-sampling is performed by convolving matrix filters across an image and remapping the data into a new array used to identify features.
“Down-sampling is achieved by convolving (sliding) different matrix filters across the photo and remapping the data into a new array that can be used to identify different features inside the image.[443]”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [443] source
May combine two claims.
PremisecitationConvolutional neural networks have been widely used to analyze tactile maps from grasping objects and to quantify their weight.
“CNNs have also been widely used to analyze and identify tactile maps generated from grabbing onto objects as well as quantifying their weight (Figure 11D and 11E).[148]”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [148] source
Probably not a substantial claim: may not pass S3 (load-bearing).
Interpretationnone givenThere is no formal proof that any machine learning algorithm will improve classification accuracy of medical data above random guessing.
“Unfortunately, there is no formal proof that any ML algorithm will enhance the classification accuracy of medical data above randomly guessing.”
Quote in the paperNot a substantial claimMay combine two claims.
InterpretationcitationMotor-driven prostheses are precise and adaptable, but their low mechanical compliance, high stiffness, and heavy weight differ substantially from natural human limbs, which may lead to physiological and psychological rejection by amputees.
“Although motor-driven prostheses are precise and adaptable, their low mechanical compliance, high stiffness, and heavy weight are substantially different to natural human limbs, which may lead to physiological and psychological rejection of prostheses by amputees.[457]”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [457] source
Probably not a substantial claim: may not pass S4 (based).
Interpretationnone givenWhen stimulating a user in response to an external impulse, matching the feedback modality of the stimulus when possible lowers the cognitive effort needed to recognize and react to the event.
“When stimulating the user in response to an external impulse, matching the feedback modality of the stimulus (when possible) results in a lower cognitive effort for the user to recognize and react to the event.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
InterpretationreasoningWhen multiple signals are provided at once, minimizing idle time between data processing and user relay is important to maintain spatiotemporal information and match visual cue expectations.
“When multiple signals are provided to the patient at once, minimizing the idle time between data processing and user relay is important to maintain spatiotemporal information about the signal as well as match the expectation from visual cues.”
Quote in the paperNot a substantial claimMay combine two claims.
InterpretationreasoningThe final accuracy of support vector machine and k-nearest neighbor models is highly dependent on the chosen feature extraction and preprocessing methods, because clean data yields high accuracy.
“In practice, the final accuracy of these models is highly dependent on the feature extraction and preprocessing methods chosen, as clean data (good features) yields a high accuracy.”
Quote in the paperSubstantial claimProbably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
PremisecitationDuring classification, convolutional neural networks downsize or section key image areas into smaller matrices, with each color pixel represented by three integer RGB values from 0 to 255.
“During classification, CNNs extract quantifiable information from these images (which are represented by a matrix of numbers) by first downsizing or sectioning off key areas of the photo into smaller matrices,[443] where each color pixel is represented by three integer RGB values ranging from 0 to 255.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [443] source
Probably not a substantial claim: may not pass S3 (load-bearing).
Premisenone givenThe k-nearest neighbors algorithm classifies incoming data by minimizing weighted distance between each testing group's points, assigning each point the closest group's label while minimizing total error.
“Meanwhile, the k-nearest neighbors algorithm classifies incoming data by minimizing the (weighted) distance between each testing group’s points (i.e., each point is classified with the closest group’s label while minimizing the total error).”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
Interpretationnone givenSimilar analysis to convolutional neural networks can be performed with artificial neural networks by first extracting key features without a matrix filter.
“It is worth noting that similar analysis can be performed using artificial neural networks, just by extracting the key features first (without using a matrix filter).”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
Premisenone givenA common medical use of convolutional neural networks is diagnosing patients from EEG, EMG, or ECG recordings.
“For sensory data in medicine, a common application of CNNs is to diagnose patients from an EEG, EMG, or ECG recording.”
Quote in the paperNot a substantial claimMay combine two claims.
InterpretationreasoningSoft robotics allow flexible artificial actuation and can serve as the base for flexible sensing electronics in prosthetic and rehabilitation applications.
“Soft robotics allow for flexible artificial actuation and can act as the base for flexible sensing electronics (as discussed above) for prosthetic and rehabilitation applications.”
Quote in the paperSubstantial claimMay combine two claims.
PremisecitationSpiking neural networks have been employed in asynchronous neuromorphic processors with negligible delay, surpassing von Neumann architectures in data access.
“In literature, SNNs have been used in dynamic neuromorphic asynchronous processors with an insignificant time delay, outperforming other modern von Neumann architectures in accessing stored data.[439]”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [439] source
May combine two claims.
Premisenone givenPrejudice is common in many other AI-based facial recognition platforms used in industry, despite racial bias in machine learning being well-documented.
“Such prejudice is actually quite common in many other AI-based facial recognition platforms used in industry, despite racial bias in ML being well-documented in the literature.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationThe narrow link between memory and CPU causes the von Neumann bottleneck, an idle period when the processor waits for data from memory because of low transfer rates.
“The limited communication line between the two units leads to the well-known von Neumann bottleneck: the inherent idle time in receiving information from computer memory due to the small transfer rate between the CPU and stored memory.[434]”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [434] source
May combine two claims.
Premisenone givenThe main issue with current rigid and metal-based medical devices is that they risk causing irritation or damage to the human body, which can negatively affect rehabilitation.
“The main issue with the current rigid and metal-based medical devices is that they carry a risk of causing irritation or damage to the human body, which can negatively affect rehabilitation.”
Quote in the paperSubstantial claimMay combine two claims.
InterpretationreasoningFlexible heaters perform better than rigid heaters, mainly due to differences in conformability and the skin contact interface.
“In comparison, flexible heaters perform better than rigid heaters, mainly due to the difference in conformability between the two and the skin contact interface.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
Interpretationnone givenThe softness of pneumatic prostheses brings uncertainty in modeling and control.
“Unfortunately, the softness of the pneumatic prosthesis brings uncertainty in modeling and control.”
Quote in the paperNot a substantial claimMay combine two claims.
PremisecitationCompared with pneumatic actuating methods, tendon-driven grippers have higher grasping speed and strength.
“Compared with pneumatic actuating methods, tendon driven grippers have a higher grasping speed and strength.[484,485]”
Quote in the paperNot a substantial claim0 of 2 sources checkedProbably not a substantial claim: may not pass S3 (load-bearing).
InterpretationreasoningCable-like actuators are more suitable to mimic natural muscles in upper and lower limb rehabilitation because of their simple structures.
“Cable-like actuators are more suitable to mimic natural muscles in this complex scenario owing to their simple structures.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S4 (based).
Interpretationnone givenA soft robot's ability to adapt to curved and irregular surfaces is crucial in hand rehabilitation for people with grasping pathologies.
“A soft robo’s ability to adapt to curved and irregular surfaces is crucial in hand rehabilitation for people with grasping pathologies.”
Quote in the paperNot a substantial claimMay combine two claims.
InterpretationcitationAlthough various soft actuators have been proven effective as artificial muscles, features such as heavy weight, slow actuation, dangers of high operating voltages, and thermal irritation of thermally activated polymers constrain their deployment in wearable rehabilitation.
“Although various soft actuators have been proven to be effective as artificial muscles, some of their features constrain their deployment in wearable rehabilitation applications, such as their heavy weight, slow actuation, dangers associated with high operating voltages, and thermal irritation of thermally activated polymers.”
Quote in the paperSubstantial claimMay combine two claims.
InterpretationreasoningWhile soft-device rehabilitation strategies look promising, portability issues still overshadow their development.
“While these rehabilitation strategies based on soft devices look promising, the portability issue still overshadows their development.”
Quote in the paperNot a substantial claimMay combine two claims.
PremisecitationIn contrast to rigid robotic hands with limited degrees of freedom, pneumatic soft hands can achieve continual deformation with a simple input signal, resulting in self-adaptation comparable to the high degrees of freedom in human hands.
“In contrast to the rigid robotic hands with limited DOFs, pneumatic soft hands can achieve continual deformation with a simple input signal, resulting in self-adaptation that is comparable to the high DOFs in human hands.[477,478]”
Quote in the paperNot a substantial claim0 of 2 sources checkedProbably not a substantial claim: may not pass S3 (load-bearing), S4 (based). May combine two claims.
Premisenone givenDiseases such as stroke and poliomyelitis induce hemiparetic gait and inhibit movement.
“Some diseases, like stroke, poliomyelitis, will induce hemiparetic gait and inhibit movement.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
Interpretationnone givenSlow actuation limits pneumatic applications.
“In addition, issues like slow actuation also limit pneumatic applications.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
Premisenone givenPneumatic devices are complicated by air tubes, pumps, and cable actuators with motors as the power source.
“Pneumatic devices are complicated by air tubes, pumps, and cable actuators with motors as the power source.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing), S4 (based). May combine two claims.
Interpretationnone givenEAP actuation is silent, making it more analogous to human muscles than other actuation modalities.
“The actuation of the EAP is silent, which is more analogous to human muscles than other actuation modalities.”
Quote in the paperNot a substantial claimMay combine two claims.
PremisecitationThe most attractive features of soft actuators over rigid prosthetics are high biocompatibility and biomimicry, in addition to mechanical compliance, lightweight, silence, high power-to-weight ratio, and safety, allowing them to conform to and imitate human muscle.
“The most attractive features of soft actuators over rigid prosthetics are their high biocompatibility and biomimicry[38] (on top of their mechanical compliance, lightweight, silence, high power-to-weight ratio, and safety), which can naturally conform to and imitate the human muscle.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [38] source
May combine two claims.
Interpretationnone givenEach power source for tendon-driven actuators has advantages, but all are too slow for prosthetic actuation.
“Each power source has its own advantages, but, unfortunately, they are all too slow for prosthetic actuation.”
Quote in the paperSubstantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationRecently, the Peltier cooling effect has been used for thermal cooling in flexible devices, also known as semiconductor coolers.
“Recently, the Peltier cooling effect has also been used for the thermal cooling in flexible devices (also known as semiconductors coolers).[499–501]”
Quote in the paperNot a substantial claim0 of 3 sources checkedMay combine two claims.
PremisecitationDielectric elastomer actuators at human scale can only generate relatively low force below 100 mN but require a high working voltage around 1000 kV to operate.
“Likewise, dielectric elastomer actuators (DEAs) at human scale can only generate relatively low force (below 100 mN) but require a high working voltage (around 1000 kV) to operate.[63]”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [63] source
May combine two claims.
PremisecitationA soft bionic ergonomic exoskeleton robot with 7 degrees of freedom can assist upper-body motions and limit stroke complications in a natural way.
“For instance, a soft bionic ergonomic exoskeleton robot with 7 DOFs is shown in Figure 13C to assist upper-body motions and to limit stroke complications in a natural way.[493]”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [493] source
Probably not a substantial claim: may not pass S3 (load-bearing).
InterpretationreasoningHeavy and rigid devices face the same challenges, which are current challenges for fully integrated wearable designs.
“All of these challenges are also faced by heavy and rigid devices, which are the current challenges for fully integrated wearable designs.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing), S4 (based). May combine two claims.
Premisenone givenPartial hand paralysis is one of the most common complications in stroke patients, and mirror therapy is a promising method for hand rehabilitation in this situation.
“Partial hand paralysis is one of the most common complications in stroke patients, and mirror therapy is a promising method for hand rehabilitation in this situation.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
Premisenone givenThe Peltier effect means that when current passes through a circuit of different conductors, heat absorption and exothermic phenomena occur at junctions depending on current direction, usually in n-p semiconductors.
“For cooling, the Peltier effect means that when there is a current through a circuit composed of different conductors, heat absorption and exothermic phenomena occur at the junctions of different conductors with different current directions, which are usually used in n-p semiconductors.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing), S4 (based). May combine two claims.
Premisenone givenMost soft materials are prone to oxidation, which reduces durability of soft actuators.
“Moreover, most soft materials are prone to oxidation, which reduces durability of soft actuators.”
Quote in the paperNot a substantial claimMay combine two claims.
PremisecitationHuman skin has both sensory perception and thermal actuating capability.
“The human skin not only has the function of sensory perception, but also has the thermal actuating capability.[512]”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [512] source
Probably not a substantial claim: may not pass S3 (load-bearing), S4 (based). May combine two claims.
Premisenone givenThese flexible stimulators are highly biocompatible, lightweight, safe, and portable in the form of implants or wearable devices.
“These flexible stimulators are highly biocompatible, lightweight, safe, and portable in the form of implants or wearable devices.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S2 (checkable), S3 (load-bearing), S4 (based). May combine two claims.
Interpretationnone givenThese soft actuators are more compatible with the human body, making them promising in many fields from bionic prosthetics to rehabilitation human-machine interfaces.
“These soft actuators are more compatible with the human body, making them promising in many fields, ranging from bionic prosthetics to rehabilitation HMIs.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
PremisecitationFaradic electrical stimulators use redox reactions and ion movement at faradaic electrodes, which provides high levels of charge for stimulation.
“while the faradic type is based on the redox reactions and ions movement at faradaic electrodes which provides high levels of charge for stimulation.[305]”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [305] source
Probably not a substantial claim: may not pass S3 (load-bearing), S4 (based).
Premisenone givenUnder constant voltage, materials with high electrical and thermal conductivity tend to achieve a fast thermal response.
“Under a constant voltage, materials with high electrical and thermal conductivity tend to achieve a fast-thermal response.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
Premisenone givenMost thermal actuators are based on Joule heating, which generates a higher temperature than the original state.
“However, most thermal actuators are based on Joule heating, whose function is to generate a higher temperature than original state.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing), S4 (based).
Premisenone givenExisting literature has documented several types of stimulation methods, such as electrostimulation, optogenetic stimulation, and vibrostimulation.
“Existing literature has documented several types of stimulation methods, such as electrostimulation, optogenetic stimulation, and vibrostimulation.”
Quote in the paperNot a substantial claimMay combine two claims.
InterpretationreasoningTactile and proprioceptive restoration as well as motor rehabilitation can be achieved by stimulating the corresponding sensory and motor nerves.
“Collectively, tactile and proprioceptive restoration as well as motor rehabilitation can be achieved by stimulating the corresponding sensory and motor nerves.”
Quote in the paperSubstantial claimMay combine two claims.
InterpretationreasoningCompared with non-invasive electrical stimulators, implantable electrodes can be placed precisely on specific sensory and motor nerves, which makes sensory feedback and modulation therapy more natural and effective.
“Compared to non-invasive electrical stimulators, implantable electrodes can be precisely inserted or attached to specific sensory afferent and motor efferent nerves, allowing sensory feedback and modulation therapy to be more natural and effective.”
Quote in the paperSubstantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
Interpretationnone givenHeat therapy is another promising application of thermal actuators for rehabilitation.
“Heat therapy is another promising application of thermal actuators for rehabilitation.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing), S4 (based).
Interpretationnone givenIn most cases, both heating and cooling are needed in thermal feedback stimulation.
“In most cases, both heating and cooling are needed in thermal feedback stimulation.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing), S4 (based).
Interpretationnone givenFrom the perspective of haptic restoration, stimulation is the user-input portion of the bidirectional information interface between the human body and prosthesis.
“From the perspective of haptic restoration, stimulation is the user-input portion of the bidirectional information interface between the human body and prosthesis.”
Quote in the paperNot a substantial claimMay combine two claims.
PremisecitationIn a multifunctional device for diagnosis and therapy of movement disorders, heaters can degrade physical bonding between nanoparticles and drugs, allowing pharmacological agents loaded in the nanoparticles to diffuse transdermally.
“In this platform, heaters can degrade the physical bonding between the nanoparticles and the drugs, and pharmacological agents loaded in the nanoparticles are thus diffused transdermally (Figure 14G).[513]”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [513] source
Probably not a substantial claim: may not pass S3 (load-bearing).
PremisereasoningUsing the Peltier heat absorption phenomenon, the cooling surface temperature can be effectively reduced.
“Taking advantage of this heat absorption phenomenon, the cooling surface temperature can be effectively reduced.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing), S4 (based). May combine two claims.
Interpretationnone givenAlthough the response speed of thermal actuators can be improved by material, structure, and power, recovery from high to low temperature is usually slow, and this thermal inertia is a concern.
“However, the recovery from high to low temperature is usually a slow process. Such thermal inertia is a matter of concern.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing), S4 (based).
Interpretationnone givenMechanical soft actuators are subject to long-term dynamic changes that make them highly susceptible to fatigue failure.
“Moreover, unlike other static devices, mechanical soft actuators are subject to long-term dynamic changes that are highly susceptible to fatigue failure of the device.”
Quote in the paperNot a substantial claimMay combine two claims.
PremisecitationA pliable Ag-Au nanocomposite elastomer thermal actuating patch shows small resistance changes and stable heating during deformation, and its softness ensures firm skin contact and reliable heat transfer even when the wrist is flexed or extended.
“Thermal actuating patch based on this material show small changes in resistance and stable heating properties during deformation. The softness of the patch ensures a firm contact with the skin and reliable heat transfer even when the wrist is flexed or extended.[503]”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [503] source
May combine two claims.
Interpretationnone givenA flexible epidermal heater can directly feed thermal information perceived by prosthesis sensors back to the skin of the residual limb accurately, functioning as AR/VR in the thermal dimension.
“Besides, the flexible epidermal heater can directly feedback the thermal information perceived by the sensors on prosthesis from the outside world back to the skin of the residual limb accurately, which can also be referred to as the AR/VR in the thermal dimension.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
InterpretationreasoningFlexible stimulators have garnered attention from academia, industry, and users.
“Thus, they have garnered the attention of academia, industry, and users.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
Premisenone givenJoule heating is the thermal effect of electric current commonly found in resistors.
“The Joule heating is the thermal effect of electric current that is commonly found in resistors.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing), S4 (based). May combine two claims.
Premisenone givenThermodynamics are no more than heating and cooling, and the electrothermal mechanisms of these two modes are almost constant: the Joule thermal effect and the Peltier cooling effect.
“Thermodynamics are no more than heating and cooling, and the electrothermal mechanism of these two modes are almost constant, i.e., the Joule thermal effect and the Peltier cooling effect.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S1 (asserted), S3 (load-bearing), S4 (based).
PremisecitationMost flexible Peltier devices developed are partially deformable by using small-sized rigid materials embedded in soft substrates.
“Most”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [511] source
Probably not a substantial claim: may not pass S3 (load-bearing), S4 (based).
Premisenone givenMechanical and thermal actuations are the two dominant types of actuation in both the human body and soft artificial devices.
“Mechanical and thermal actuations are the two dominant types of actuation both in human body and soft artificial devices.”
Quote in the paperNot a substantial claimMay combine two claims.
PremisecitationLinear-type spinal probes are less invasive and easier to implant, but paddle-type probes have a better stimulation effect.
“The former is less invasiveness and easier to implant. But the latter one have a better stimulation effect.[547]”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [547] source
Probably not a substantial claim: may not pass S3 (load-bearing).
Interpretationnone givenOptogenetics still exists mainly in theoretical and animal experiments, with few practical applications to humans currently.
“In spite of its appealing advantages and functions, optogenetics is still mainly exist in theoretical and animal experiments, without few practical applications to humans, currently.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
Premisenone givenLight delivery is a vexing challenge in optogenetic applications, which typically require implantable optical stimulators.
“Light delivery has proven to be a vexing challenge in optogenetic applications, which typically require implantable optical stimulators.”
Quote in the paperNot a substantial claimMay combine two claims.
PremisecitationLIFEs are wire-shaped and flexible to accommodate radial bending of cable-like nerves.
“LIFEs tend to be wire-shaped and flexible to accommodate the radial bending of cable-like nerves.[553]”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [553] source
May combine two claims.
PremisecitationUsing commercial 2D stimulation electrodes (silicone sheet 4 cm × 4 cm, 1 mm thick, 60 electrodes), electrical stimulation can modulate sensory intensity, type of sensation, and evocation of sensation from fingers to upper arm.
“by using commercial 2D stimulation electrodes, which consist of a silicone sheet (4 cm × 4 cm in size and 1 mm thick) and 60 electrodes facing the brain (Figure 15A), researchers have found that sensory intensity, type of sensation, and evocation of sensation from a range of locations from the fingers to the upper arm can be modulated by electrical stimulation (Figure 15B).[546]”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [546] source
Probably not a substantial claim: may not pass S3 (load-bearing).
PremisereasoningTitanium nitrides and oxides (TiN and TiO2) are popular for capacitive electrical stimulators because they are chemically inert and have high electrochemical safety limits.
“Generally, nitrides and oxides of titanium (TiN and TiO2) are popular options for capacitive electrical stimulators due to their chemical inertness and high electrochemical safety limitation.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationTraditionally, capacitive and Faraday electrical stimulation occur simultaneously on the surface of metal stimulating electrodes such as Au and Pt.
“Traditionally, capacitive and Faraday electrical stimulation occurs simultaneously on the surface of metal stimulating electrodes (Au and Pt).[530,531]”
Quote in the paperNot a substantial claim0 of 2 sources checkedMay combine two claims.
PremisecitationThe spinal location of e-dura allows multiple stimulation types, including electrical modulation and local drug application, to alleviate neurological defects over a long period.
“This spinal location allows for multitype stimulations, like electrical modulation and local drug application to alleviate the neurological defects for a long time.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [548] source
Probably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationA PI-Pt-IrOx stack was inserted transversely into a peripheral nerve with a pre-attached needle as an example of TIME.
“As an example of TIME, a PI-Pt-IrOx stack was inserted into the peripheral nerve in a transverse manner with the aid of a pre-attached needle.[552]”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [552] source
Probably not a substantial claim: may not pass S3 (load-bearing), S4 (based).
InterpretationreasoningBy mimicking the mechanical properties (modulus, thickness) of human skin, most flexible wearable devices are becoming more comfortable and conformable than rigid stimulators for direct attachment to human skin and evoking sensory and motor function.
“By mimicking the mechanical properties (modulus, thickness) of human skin, most flexible wearable devices are becoming more comfortable and conformable than rigid stimulators to attach on human skin directly and evoke the sensory and motor function.”
Quote in the paperNot a substantial claimMay combine two claims.
PremisecitationFor force stimuli, the location of the stimulus within the array, the magnitude of the force, and the direction of the stimulus force are all relevant factors.
“E.g. for force stimuli, the location of the stimulus within the array, the magnitude of the force, and even the direction of the stimulus force are all relevant factors.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
PremisereasoningElectromagnetic stimulators can balance the frequency range and magnitude of stimulation force, based on the force applied to a conductor in a magnetic field.
“In addition to the stimulation principles mentioned above, electromagnetic stimulator can balance the frequency range and the magnitude of the stimulation force, whose mechanism is the based on the force applied to the conductor in a magnetic field.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S4 (based). May combine two claims.
Interpretationnone givenConventional electrical stimulators cannot work without bulky power sources, which greatly confines their portability.
“Conventional electrical stimulators cannot work without bulky power sources, which greatly confined their portability.”
Quote in the paperNot a substantial claimMay combine two claims.
PremisecitationDEAs naturally have advantages such as an extremely wide range of stimulation frequencies and easy integration at high spatial density.
“When it comes to the high bandwidth vibro-stimulation, it is necessary to mention DEAs,[586–591] which naturally have the advantages like an extremely wide range of stimulation frequencies and easy integration at high spatial density.”
Quote in the paperNot a substantial claim0 of 6 sources checkedMay combine two claims.
PremisecitationSeveral mechanisms of micromechanical stimulation have been reported, including forces generated by fluids (hydraulic, pneumatic) and heat-induced deformation.
“Several mechanisms of micromechanical stimulation have been reported, common ones such as forces generated by fluids (hydraulic, pneumatic),[579,580] heat-induced deformation,[581–583] etc.”
Quote in the paperNot a substantial claim0 of 5 sources checkedMay combine two claims.
Premisenone givenDEAs have drawbacks hindering adoption, including limited actuation force and amplitude and the need for high operating voltage (more than 1 kV).
“However, there are still some drawbacks that hinder its adoption, such as limited actuation force and amplitude, and the need for high operating voltage (more 1kV).”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing), S4 (based). May combine two claims.
InterpretationreasoningCompared with implantable stimulators, noninvasive stimulators require no surgical intervention, which greatly enhances convenience and safety of stimulation.
“Compared with implantable stimulators, noninvasive stimulators needn’t any surgical intervention, which greatly enhances the convenience and safety of stimulation.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing), S4 (based).
Interpretationnone givenThese noninvasive methods can serve as multidimensional, multisensory complements to VR/AR in HMI for a more immersive and realistic experience.
“These methods also can serve as multidimensional, multisensory complements to VR/AR in HMI for a more immersive and realistic experience.”
Quote in the paperNot a substantial claimMay combine two claims.
PremisecitationA coin-sized (18 mm) electromagnetic exciter has a milliampere operating current, a Young's modulus of 130 kPa close to skin modulus, and an output amplitude of 300 μm.
“For example, Figure 16A shows a coin-sized (18 mm) electromagnetic exciter with a milliampere operating current, a Young's modulus of 130 kPa, close to the skin modulus, and an output amplitude of 300 μm (Figure 16B and 16C).[598]”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [598] source
Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
Interpretationnone givenPhysical integration of sensors and actuators, and communication and transformation of in vivo signal-electrical signal-physical information, are potentially challenges for deepening scientific research.
“Among these, the physical integration of sensors and actuators, the communication and transformation of in vivo signal-electrical signal-physical information are potentially challenges for the deepening of scientific research.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
InterpretationreasoningMachine learning enhanced hardware design can help limit the number of sensors and electronics needed to collect data.
“Machine learning enhanced hardware design can help limit the number of sensors and electronics needed to collect data.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
PremisereasoningUnder the guidance of the signal, the soft robot (prosthesis) moves and perceives external information using the e-skin mounted on the actuator.
“Under the guidance of the signal, the soft robots (prosthesis) moves and perceives external information using the e-skin mounted on the actuator.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S2 (checkable), S3 (load-bearing), S4 (based).
Premisenone givenIn sensors, the balance and optimization of sensitivity, linearity, response time, limit of detection, measuring range, hysteresis and other properties are constantly pursued by the academic community.
“In sensors, the balance and optimization of sensitivity, linearity, response time, limit of detection, measuring range, hysteresis and other properties are constantly pursued by the academic community.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
InterpretationcitationSystem integration is the ultimate goal for biomimetic prosthetics and is a closed loop where all the above-mentioned device types are connected.
“System integration is the ultimate goal for biomimetic prosthetics and is a closed loop where all the above-mentioned device types are connected.[621]”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [621]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
May combine two claims.
Interpretationnone givenThe fabrication of many flexible devices and electronics is still based on manual work, which increases uncertainty of device performance and difficulty of mass production.
“The fabrication of many flexible devices and electronics is still based on manual work, which increases the uncertainty of the device performance as well as the difficulty of mass production.”
Quote in the paperSubstantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
InterpretationreasoningMaintaining proper power supply is another important issue in HMI devices.
“Maintaining proper power supply is another important issue in HMI devices.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing), S4 (based). May combine two claims.
Premisenone givenFor neural interfaces, impedance in recording and charge injection capability in stimulation are key properties.
“While for neural interfaces, impedance in recording and charge injection capability in stimulation are key properties.”
Quote in the paperNot a substantial claimMay combine two claims.
PremisecitationThere have been many outstanding examples of exploiting machine learning in sensors and actuators, such as extracting motion intent from electrophysiological signals, using haptics to identify object categories, decoupling multimodal signals from cross-reactive sensor arrays, and controlling soft robots.
“There have been many outstanding examples of exploiting machine learning in the field of sensors and actuators, such as extracting motion intent from electrophysiological signals,[287,610] using haptics to identify object categories,[160,611] decoupling multimodal signals from cross-reactive sensor arrays,[231,612] and controlling soft robots[613,614].”
Quote in the paperNot a substantial claim0 of 6 sources checkedProbably not a substantial claim: may not pass S3 (load-bearing), S4 (based). May combine two claims.
Premisenone givenThe reason humans are specialized in perception and movement is not only the excellent performance of receptors and musculoskeletons but also the brain's skill in processing raw information.
“The reason why humans are specialized in perception and movement is not only due to the excellent performance of receptors and musculoskeletons, but also because the brain is skilled in processing this raw information.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
Premisenone givenSensors, recorders, artificial neurons, actuators, and stimulators are all devices based on soft technologies that acquire and process information from external environments and the human body.
“Sensors, recorders, artificial neurons, actuators, and stimulators are all devices that are based on soft technologies that acquire and process information from external environments and the human body.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
InterpretationreasoningEach of these systems is subjected to human movement, requiring dexterity as the devices change shape.
“Each of these systems is thereby subjected to human movement, requiring dexterity as the devices change shape.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing), S4 (based). May combine two claims.
Interpretationnone givenHigh-density implantable electrical stimulators can easily exceed cell safety limits while achieving stimulation margins.
“for example, high-density implantable electrical stimulators can easily exceed cell safety limits while achieving stimulation margins.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S4 (based).
Interpretationnone givenStimulators consume much more energy than sensors.
“One of the differences between stimulators and sensors is that stimulators consume much more energy than sensors.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S4 (based).
Interpretationnone givenFlexible devices serve as interfaces that establish a solid foundation for the human body to obtain external information or receive therapeutic treatment.
“These flexible devices serve as interfaces that establish a solid foundation for the human body to obtain external information or to receive therapeutic treatment.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
PremisereasoningResearchers are currently investigating wireless-powered and self-powered devices, which is of utmost importance for invasive devices that currently require surgery for battery replacement.
“Researchers are currently investigating wireless-powered and self-powered devices, which is of upmost important for invasive devices that currently require surgery for battery replacement.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S2 (checkable), S3 (load-bearing), S4 (based). May combine two claims.
Interpretationnone givenVarious implantable or wearable stimulators have unique advantages, and multimodal stimulation is a potentially advantageous pooling option.
“Various implantable or wearable stimulators have unique advantages, and multimodal stimulation is a potentially advantageous pooling option.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing), S4 (based).
InterpretationreasoningDue to structural, material, or fabrication limitations, the spatial density of many stimulation arrays is limited.
“Next challenge is stimulation density, due to structural, material, or fabrication limitations, the spatial density of many stimulation arrays is limited”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
Premisenone givenFlexible electrophysiological recorders capture movement intent from the human body, decode it, and form a prosthetic control signal.
“Specifically, flexible electrophysiological recorders capture the movement intent from human body, decodes it, and forms a prosthetic control signal.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
Premisenone givenA flexible prosthetic system has a representative flow of information with various integrated components.
“A flexible prosthetic system has a representative flow of information with various integrated components.”
Quote in the paperNot a substantial claimMay combine two claims.
PremisecitationInterface problems mainly arise in heterogeneous integration of different materials, such as material bonding and embedding, which can be addressed by micromechanics, chemical bonding links, etc.
“For both of these examples, interface problems mainly arise in heterogeneous integration of different materials, such as for material bonding and embedding, which can be addressed by micromechanics, chemical bonding links, etc.[609]”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [609] source
Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
PremisereasoningThis information is stimulated back to the body in the form of biocompatible signals through the flexible stimulator, constituting a complete closed-loop.
“In turn, this information is stimulated back to the body in the form of biocompatible signals through the flexible stimulator, constituting a complete closed-loop.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
Premisenone givenMany conceptual devices based on various materials have been validated in academic laboratories.
“While many conceptual devices based on various materials have been validated in academic laboratories.”
Quote in the paperNot a substantial claimMay combine two claims.
PremisecitationElectrophysiological signals recorded by a flexible recorder are processed by machine learning algorithms to decode movement intentions, which can be used to control a soft robotic hand.
“For example, the electrophysiological signals recorded by a flexible recorder are processed by machine learning algorithms to decode movement intentions, which can be used to control a soft robotic hand.”
Quote in the paperSubstantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
Premisenone givenActuation range, amplitude, frequency, and response time are criteria that determine the performance of soft actuators.
“Actuation range, amplitude, frequency, response time are the criteria that determine the performance of soft actuators.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S2 (checkable). May combine two claims.
InterpretationreasoningTailoring the fabrication technique to a mass-producible platform or exploring new processing technologies can boost the market application of low-cost soft devices.
“Therefore, tailoring the fabrication technique to such mass-producible platform or exploring new processing technologies can boost the market application of these low-cost soft devices.”
Quote in the paperNot a substantial claimMay combine two claims.
Interpretationnone givenTraditional tethered and battery power suffer from motion restrictions and sophisticated recharging processes respectively, which are obstacles to the application of both wearable and implantable devices.
“Traditional tethered and battery power suffer from motion restrictions and sophisticated recharging processes respectively, which are obstacles to the application of both wearable and implantable devices.”
Quote in the paperSubstantial claimProbably not a substantial claim: may not pass S4 (based).
Interpretationnone givenMost hardware research is still delinked from intelligent algorithms.
“However, most of the hardware research is still delinked from intelligent algorithms.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing), S4 (based).
InterpretationreasoningThis bridging role is especially true in medical robotics for people with disabilities, such as prosthetic engineering and rehabilitation science.
“This is especially true in medical robotics for people with disabilities, such as prosthetic engineering, rehabilitation science and other related fields.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing), S4 (based).
Premisenone givenSoft devices involve comprehensive technologies, including flexible sensing, soft actuation, brain-machine interface, and other relevant domains.
“Soft devices involve extremely comprehensive technologies, including flexible sensing, soft actuation, brain-machine interface and other relevant domains.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing), S4 (based). May combine two claims.
Interpretationnone givenThese devices integrate information flow from the human body with that from the external environment and use ML methods for deep processing to control machines for target actuation effects or feedback to humans in a biocompatible form.
“These devices based on new materials and structures integrate the information flow from the human body with that from the external environment, and use ML methods for deep processing to control machines for achieving target actuation effects or feedback to humans themselves in a biocompatible form.”
Quote in the paperNot a substantial claimMay combine two claims.
PremisecitationFor wireless energy, NFCs and ultrasonic are good powering methods, but still need the energy transmitter and receiving energy at a certain range.
“For wireless energy, NFCs[568] and ultrasonic[372] are good powering methods, but still need the energy transmitter, as well as receiving energy at a certain range”
Quote in the paperNot a substantial claim0 of 2 sources checkedProbably not a substantial claim: may not pass S2 (checkable), S3 (load-bearing).
InterpretationreasoningFor soft devices with high energy consumption, such as soft prostheses, the energy supply method still needs further exploration.
“However, for soft devices with high energy consumption, such as soft prostheses, the energy supply method still needs to be further explored.”
Quote in the paperNot a substantial claimMay combine two claims.
PremisecitationImplantable systems for motion-related epilepsy rely on real-time acquisition and analysis of pre-seizure brain electrical signals and perform compensatory electrical stimulation to eliminate abnormal brain waves and stop the epilepsy midway.
“For example, implantable systems for motion-related epilepsy rely on real-time acquisition and analysis of pre-seizure brain electrical signals and perform compensatory electrical stimulation to eliminate abnormal brain waves and stop the epilepsy midway.[606]”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [606] source
Probably not a substantial claim: may not pass S2 (checkable), S4 (based).
InterpretationreasoningBecause of favorable biocompatibility, high bionic, low-cost, and safety features, soft electronics and devices can gradually shoulder the role of bridging the gap between humans and machines.
“Because of favorable biocompatibility, high bionic, low-cost, and safety features, soft electronics and devices, a field that has emerged in recent decades, can gradually shoulder the role of bridging the gap between the human and machines.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing), S4 (based).
Interpretationnone givenThe potential development of flexible devices for many stimulation mechanisms, such as acoustic stimulation, is still not receiving community attention.
“Finally, the potential development of flexible devices for many stimulation mechanisms is still not receiving community attention, such as acoustic stimulation, and these flexible devices can also potentially be explored as interfaces for HMI.”
Quote in the paperNot a substantial claim
The paper relies on this without support.
E-skin can capture thermal, humidity, physiological, chemical, and tactile sensations better than human skin while maintaining high spatiotemporal resolution under varying strain.
“Now the base of many wearable devices, e-skin has been shown to outperformed human skin in capturing thermal, humidity, physiological, various chemical, and tactile sensations while maintaining a high spatiotemporal resolution under varying degrees of strain.”
The paper relies on this without support.
Recording multimodal chemical, temperature, and pressure signals can drain power and electrically interfere with sensor reading accuracy.
“Unfortunately, recording these multimodal chemical, temperature, and pressure signals can drain power and electrically interfere with the accuracy of sensor readings.”
The paper relies on this without support.
The inherent limitation of wearable robotics is that electronics are not recognized as an extension of the human body, causing high cognitive effort for the user to control.
“At its core, the inherent limitation of wearable robotics is that the electronics are not recognized as an extension of the human body, resulting in a high cognitive effort for the user to control.”
The paper relies on this without support.
Most existing commercial prostheses lack sensory capabilities, preventing amputees from actively and passively perceiving external information and diminishing the user's ownership of the prosthesis.
“Most existing commercial prostheses lack sensory capabilities and prevent amputees from actively and passively perceiving external information, which dramatically diminishing the user's ownership of the prosthesis.”
The paper relies on this without support.
Integrating e-skins may limit their sensing performance.
“However, integrating e-skins may limit their sensing performance.”
The authors state this as an assumption.
The user's intentions can be extracted from the activation of the remnant muscles.
“The exploration of electromyography for prosthesis control is based on the assumption that the user’s intentions can be extracted from the activation of the remnant muscles.[364,365]”
The paper relies on this without support.
Electrical signals are the predominant form of nerve excitation in the human body.
“Electrical signals are the predominant form of nerve excitation propagating in the human body.”
Cites
IOP Conference Series: Materials Science and Engineering
(2022) · IOP Conference Series Materials Science and Engineering · doi:10.1088/1757-899x/1231/1/011001 · Cited by 12,131 · see citing works
Piezoelectric Nanogenerators Based on Zinc Oxide Nanowire Arrays
Wang, Z. L., & Song, J. (2006) · Science · doi:10.1126/science.1124005 · Cited by 7,922 · see citing works
Flexible triboelectric generator
Fan, F.-R., Tian, Z.-Q., & Lin Wang, Z. (2012) · Nano Energy · doi:10.1016/j.nanoen.2012.01.004 · Cited by 6,705 · see citing works
Design, fabrication and control of soft robots
Rus, D., & Tolley, M. T. (2015) · Nature · doi:10.1038/nature14543 · Cited by 5,825 · see citing works
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087 · see citing works
Self-citationKim, D.-H., Lu, N., Ma, R., Kim, Y.-S., Kim, R.-H., Wang, S., Wu, J., Won, S. M., Tao, H., Islam, A., et al. (2011) · Science · doi:10.1126/science.1206157 · Cited by 4,836 · see citing works
The origin of extracellular fields and currents — EEG, ECoG, LFP and spikes
Buzsáki, G., Anastassiou, C. A., & Koch, C. (2012) · Nature Reviews Neuroscience · doi:10.1038/nrn3241 · Cited by 4,225 · see citing works
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295 · see citing works
A stretchable carbon nanotube strain sensor for human-motion detection
Yamada, T., Hayamizu, Y., Yamamoto, Y., Yomogida, Y., Izadi-Najafabadi, A., Futaba, D. N., & Hata, K. (2011) · Nature Nanotechnology · doi:10.1038/nnano.2011.36 · Cited by 3,247 · see citing works
Skin-like pressure and strain sensors based on transparent elastic films of carbon nanotubes
Lipomi, D. J., Vosgueritchian, M., Tee, B. C.-K., Hellstrom, S. L., Lee, J. A., Fox, C. H., & Bao, Z. (2011) · Nature Nanotechnology · doi:10.1038/nnano.2011.184 · Cited by 3,188 · see citing works
Reach and grasp by people with tetraplegia using a neurally controlled robotic arm
Hochberg, L. R., Bacher, D., Jarosiewicz, B., Masse, N. Y., Simeral, J. D., Vogel, J., Haddadin, S., Liu, J., Cash, S. S., van der Smagt, P., et al. (2012) · Nature · doi:10.1038/nature11076 · Cited by 2,719 · see citing works
An ultra-lightweight design for imperceptible plastic electronics
Kaltenbrunner, M., Sekitani, T., Reeder, J., Yokota, T., Kuribara, K., Tokuhara, T., Drack, M., Schwödiauer, R., Graz, I., Bauer-Gogonea, S., et al. (2013) · Nature · doi:10.1038/nature12314 · Cited by 2,485 · see citing works
Hammock, M. L., Chortos, A., Tee, B. C. ‐., Tok, J. B. ‐., & Bao, Z. (2013) · Advanced Materials · doi:10.1002/adma.201302240 · Cited by 2,396 · see citing works
Pursuing prosthetic electronic skin
Chortos, A., Liu, J., & Bao, Z. (2016) · Nature Materials · doi:10.1038/nmat4671 · Cited by 2,396 · see citing works
Neural Stimulation and Recording Electrodes
Cogan, S. F. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160518 · Cited by 2,243 · see citing works
Proske, U., & Gandevia, S. C. (2012) · Physiological Reviews · doi:10.1152/physrev.00048.2011 · Cited by 2,223 · see citing works
Skin electronics from scalable fabrication of an intrinsically stretchable transistor array
Wang, S., Xu, J., Wang, W., Wang, G. N., Rastak, R., Molina‐Lopez, F., Chung, J. W., Niu, S., Feig, V. R., Lopez, J., et al. (2018) · Nature · doi:10.1038/nature25494 · Cited by 2,202 · see citing works
Fully integrated silicon probes for high-density recording of neural activity
Jun, J. J., Steinmetz, N. A., Siegle, J. H., Denman, D. J., Bauza, M., Barbarits, B., Lee, A. K., Anastassiou, C. A., Andrei, A., Aydın, Ç., et al. (2017) · Nature · doi:10.1038/nature24636 · Cited by 2,190 · see citing works
Trung, T. Q., & Lee, N. (2016) · Advanced Materials · doi:10.1002/adma.201504244 · Cited by 2,160 · see citing works
A new strategy for multifunction myoelectric control
Hudgins, B., Parker, P., & Scott, R. N. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.204774 · Cited by 2,149 · see citing works
Soft robotics: a bioinspired evolution in robotics
Kim, S., Laschi, C., & Trimmer, B. (2013) · Trends in Biotechnology · doi:10.1016/j.tibtech.2013.03.002 · Cited by 2,092 · see citing works
Schwartz, G., Tee, B. C.-K., Mei, J., Appleton, A. L., Kim, D. H., Wang, H., & Bao, Z. (2013) · Nature Communications · doi:10.1038/ncomms2832 · Cited by 2,042 · see citing works
Lee, H., Choi, T. K., Lee, Y. B., Cho, H. R., Ghaffari, R., Wang, L., Choi, H. J., Chung, T. D., Lu, N., Hyeon, T., et al. (2016) · Nature Nanotechnology · doi:10.1038/nnano.2016.38 · Cited by 1,802 · see citing works
Stretchable, Transparent, Ionic Conductors
Keplinger, C., Sun, J.-Y., Foo, C. C., Rothemund, P., Whitesides, G. M., & Suo, Z. (2013) · Science · doi:10.1126/science.1240228 · Cited by 1,754 · see citing works
Lab-on-Skin: A Review of Flexible and Stretchable Electronics for Wearable Health Monitoring
Liu, Y., Pharr, M., & Salvatore, G. A. (2017) · ACS Nano · doi:10.1021/acsnano.7b04898 · Cited by 1,725 · see citing works
Dissolvable films of silk fibroin for ultrathin conformal bio-integrated electronics
Kim, D.-H., Viventi, J., Amsden, J. J., Xiao, J., Vigeland, L., Kim, Y.-S., Blanco, J. A., Panilaitis, B., Frechette, E. S., Contreras, D., et al. (2010) · Nature Materials · doi:10.1038/nmat2745 · Cited by 1,721 · see citing works
A flexible and highly sensitive strain-gauge sensor using reversible interlocking of nanofibres
Pang, C., Lee, G.-Y., Kim, T.-I., Kim, S. M., Kim, H. N., Ahn, S.-H., & Suh, K.-Y. (2012) · Nature Materials · doi:10.1038/nmat3380 · Cited by 1,695 · see citing works
Engineered doping of organic semiconductors for enhanced thermoelectric efficiency
Kim, G.-H., Shao, L., Zhang, K., & Pipe, K. P. (2013) · Nature Materials · doi:10.1038/nmat3635 · Cited by 1,688 · see citing works
Yang, J. C., Mun, J., Kwon, S. Y., Park, S., Bao, Z., & Park, S. (2019) · Advanced Materials · doi:10.1002/adma.201904765 · Cited by 1,641 · see citing works
Ultrasensitive mechanical crack-based sensor inspired by the spider sensory system
Kang, D., Pikhitsa, P. V., Choi, Y. W., Lee, C., Shin, S. S., Piao, L., Park, B., Suh, K.-Y., Kim, T.-I., & Choi, M. (2014) · Nature · doi:10.1038/nature14002 · Cited by 1,626 · see citing works
Measurement and modeling of McKibben pneumatic artificial muscles
Chou, C.-P., & Hannaford, B. (1996) · IEEE Transactions on Robotics and Automation · doi:10.1109/70.481753 · Cited by 1,589 · see citing works
Pan, L., Chortos, A., Yu, G., Wang, Y., Isaacson, S., Allen, R., Shi, Y., Dauskardt, R., & Bao, Z. (2014) · Nature Communications · doi:10.1038/ncomms4002 · Cited by 1,519 · see citing works
Bariya, M., Nyein, H. Y. Y., & Javey, A. (2018) · Nature Electronics · doi:10.1038/s41928-018-0043-y · Cited by 1,486 · see citing works
A bioinspired flexible organic artificial afferent nerve
Kim, Y., Chortos, A., Xu, W., Liu, Y., Oh, J. Y., Son, D., Kang, J., Foudeh, A. M., Zhu, C., Lee, Y., et al. (2018) · Science · doi:10.1126/science.aao0098 · Cited by 1,466 · see citing works
Multifunctional wearable devices for diagnosis and therapy of movement disorders
Son, D., Lee, J., Qiao, S., Ghaffari, R., Kim, J., Lee, J. E., Song, C., Kim, S. J., Lee, D. J., Jun, S. W., et al. (2014) · Nature Nanotechnology · doi:10.1038/nnano.2014.38 · Cited by 1,462 · see citing works
Sharifi, S., Behzadi, S., Laurent, S., Laird Forrest, M., Stroeve, P., & Mahmoudi, M. (2012) · Chem. Soc. Rev. · doi:10.1039/c1cs15188f · Cited by 1,460 · see citing works
Stretchable silicon nanoribbon electronics for skin prosthesis
Kim, J., Lee, M., Shim, H. J., Ghaffari, R., Cho, H. R., Son, D., Jung, Y. H., Soh, M., Choi, C., Jung, S., et al. (2014) · Nature Communications · doi:10.1038/ncomms6747 · Cited by 1,435 · see citing works
Biomedical applications of soft robotics
Cianchetti, M., Laschi, C., Menciassi, A., & Dario, P. (2018) · Nature Reviews Materials · doi:10.1038/s41578-018-0022-y · Cited by 1,435 · see citing works
Skin-inspired highly stretchable and conformable matrix networks for multifunctional sensing
Hua, Q., Sun, J., Liu, H., Bao, R., Yu, R., Zhai, J., Pan, C., & Wang, Z. L. (2018) · Nature Communications · doi:10.1038/s41467-017-02685-9 · Cited by 1,413 · see citing works
Potential Biases in Machine Learning Algorithms Using Electronic Health Record Data
Gianfrancesco, M. A., Tamang, S., Yazdany, J., & Schmajuk, G. (2018) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2018.3763 · Cited by 1,395 · see citing works
Highly stretchable electroluminescent skin for optical signaling and tactile sensing
Larson, C., Peele, B., Li, S., Robinson, S., Totaro, M., Beccai, L., Mazzolai, B., & Shepherd, R. (2016) · Science · doi:10.1126/science.aac5082 · Cited by 1,393 · see citing works
Gamma frequency entrainment attenuates amyloid load and modifies microglia
Iaccarino, H. F., Singer, A. C., Martorell, A. J., Rudenko, A., Gao, F., Gillingham, T. Z., Mathys, H., Seo, J., Kritskiy, O., Abdurrob, F., et al. (2016) · Nature · doi:10.1038/nature20587 · Cited by 1,328 · see citing works
Wearable and flexible electronics for continuous molecular monitoring
Yang, Y., & Gao, W. (2019) · Chemical Society Reviews · doi:10.1039/c7cs00730b · Cited by 1,315 · see citing works
Self-citationA laser-engraved wearable sensor for sensitive detection of uric acid and tyrosine in sweat
Yang, Y., Song, Y., Bo, X., Min, J., Pak, O. S., Zhu, L., Wang, M., Tu, J., Kogan, A., Zhang, H., et al. (2020) · Nature Biotechnology · doi:10.1038/s41587-019-0321-x · Cited by 1,270 · see citing works
Self-citationHighly stretchable polymer semiconductor films through the nanoconfinement effect
Xu, J., Wang, S., Wang, G. N., Zhu, C., Luo, S., Jin, L., Gu, X., Chen, S., Feig, V. R., To, J. W. F., et al. (2017) · Science · doi:10.1126/science.aah4496 · Cited by 1,258 · see citing works
Flexible organic transistors and circuits with extreme bending stability
Sekitani, T., Zschieschang, U., Klauk, H., & Someya, T. (2010) · Nature Materials · doi:10.1038/nmat2896 · Cited by 1,253 · see citing works
Ultrathin conformal devices for precise and continuous thermal characterization of human skin
Webb, R. C., Bonifas, A. P., Behnaz, A., Zhang, Y., Yu, K. J., Cheng, H., Shi, M., Bian, Z., Liu, Z., Kim, Y.-S., et al. (2013) · Nature Materials · doi:10.1038/nmat3755 · Cited by 1,229 · see citing works
An Integrated Brain-Machine Interface Platform With Thousands of Channels
Musk, E., & Neuralink (2019) · Journal of Medical Internet Research · doi:10.2196/16194 · Cited by 1,206 · see citing works
Sun, J., Keplinger, C., Whitesides, G. M., & Suo, Z. (2014) · Advanced Materials · doi:10.1002/adma.201403441 · Cited by 1,200 · see citing works
Soft Microfluidic Assemblies of Sensors, Circuits, and Radios for the Skin
Xu, S., Zhang, Y., Jia, L., Mathewson, K. E., Jang, K.-I., Kim, J., Fu, H., Huang, X., Chava, P., Wang, R., et al. (2014) · Science · doi:10.1126/science.1250169 · Cited by 1,199 · see citing works
User-interactive electronic skin for instantaneous pressure visualization
Wang, C., Hwang, D., Yu, Z., Takei, K., Park, J., Chen, T., Ma, B., & Javey, A. (2013) · Nature Materials · doi:10.1038/nmat3711 · Cited by 1,182 · see citing works
Inflammation-free, gas-permeable, lightweight, stretchable on-skin electronics with nanomeshes
Miyamoto, A., Lee, S., Cooray, N. F., Lee, S., Mori, M., Matsuhisa, N., Jin, H., Yoda, L., Yokota, T., Itoh, A., et al. (2017) · Nature Nanotechnology · doi:10.1038/nnano.2017.125 · Cited by 1,181 · see citing works
Wang, E., Yao, H.-B., Chen, Y., Wang, G., Gao, W., Sun, Y., Guo, J., Hu, J., Jiang, C., & Hu, J. (2013) · Cellular Physiology and Biochemistry · doi:10.1159/000350082 · Cited by 1,176 · see citing works
Self-citationInjectable, Cellular-Scale Optoelectronics with Applications for Wireless Optogenetics
Kim, T.-I., McCall, J. G., Jung, Y. H., Huang, X., Siuda, E. R., Li, Y., Song, J., Song, Y. M., Pao, H. A., Kim, R.-H., et al. (2013) · Science · doi:10.1126/science.1232437 · Cited by 1,174 · see citing works
Learning the signatures of the human grasp using a scalable tactile glove
Sundaram, S., Kellnhofer, P., Li, Y., Zhu, J.-Y., Torralba, A., & Matusik, W. (2019) · Nature · doi:10.1038/s41586-019-1234-z · Cited by 1,162 · see citing works
Viventi, J., Kim, D.-H., Vigeland, L., Frechette, E. S., Blanco, J. A., Kim, Y.-S., Avrin, A. E., Tiruvadi, V. R., Hwang, S.-W., Vanleer, A. C., et al. (2011) · Nature Neuroscience · doi:10.1038/nn.2973 · Cited by 1,136 · see citing works
First draft of a report on the EDVAC
von Neumann, J. (1993) · IEEE Annals of the History of Computing · doi:10.1109/85.238389 · Cited by 1,112 · see citing works
Large-area display textiles integrated with functional systems
Shi, X., Zuo, Y., Zhai, P., Shen, J., Yang, Y., Gao, Z., Liao, M., Wu, J., Wang, J., Xu, X., et al. (2021) · Nature · doi:10.1038/s41586-021-03295-8 · Cited by 1,089 · see citing works
A novel type of compliant and underactuated robotic hand for dexterous grasping
Deimel, R., & Brock, O. (2016) · The International Journal of Robotics Research · doi:10.1177/0278364915592961 · Cited by 1,084 · see citing works
Electronic dura mater for long-term multimodal neural interfaces
Minev, I. R., Musienko, P., Hirsch, A., Barraud, Q., Wenger, N., Moraud, E. M., Gandar, J., Capogrosso, M., Milekovic, T., Asboth, L., et al. (2015) · Science · doi:10.1126/science.1260318 · Cited by 1,082 · see citing works
Hydraulically amplified self-healing electrostatic actuators with muscle-like performance
Acome, E., Mitchell, S. K., Morrissey, T. G., Emmett, M. B., Benjamin, C., King, M., Radakovitz, M., & Keplinger, C. (2018) · Science · doi:10.1126/science.aao6139 · Cited by 1,072 · see citing works
Self-powered ultra-flexible electronics via nano-grating-patterned organic photovoltaics
Park, S., Heo, S. W., Lee, W., Inoue, D., Jiang, Z., Yu, K., Jinno, H., Hashizume, D., Sekino, M., Yokota, T., et al. (2018) · Nature · doi:10.1038/s41586-018-0536-x · Cited by 1,068 · see citing works
Markvicka, E. J., Bartlett, M. D., Huang, X., & Majidi, C. (2018) · Nature Materials · doi:10.1038/s41563-018-0084-7 · Cited by 1,067 · see citing works
Control strategies for active lower extremity prosthetics and orthotics: a review
Tucker, M. R., Olivier, J., Pagel, A., Bleuler, H., Bouri, M., Lambercy, O., Millán, J. D. R., Riener, R., Vallery, H., & Gassert, R. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-12-1 · Cited by 1,047 · see citing works
Wearable multifunctional sensors using printed stretchable conductors made of silver nanowires
Yao, S., & Zhu, Y. (2014) · Nanoscale · doi:10.1039/c3nr05496a · Cited by 1,028 · see citing works
Skin-integrated wireless haptic interfaces for virtual and augmented reality
Yu, X., Xie, Z., Yu, Y., Lee, J., Vazquez-Guardado, A., Luan, H., Ruban, J., Ning, X., Akhtar, A., Li, D., et al. (2019) · Nature · doi:10.1038/s41586-019-1687-0 · Cited by 1,025 · see citing works
Ultraflexible organic photonic skin
Yokota, T., Zalar, P., Kaltenbrunner, M., Jinno, H., Matsuhisa, N., Kitanosako, H., Tachibana, Y., Yukita, W., Koizumi, M., & Someya, T. (2016) · Science Advances · doi:10.1126/sciadv.1501856 · Cited by 1,024 · see citing works
Bioresorbable silicon electronic sensors for the brain
Kang, S.-K., Murphy, R. K. J., Hwang, S.-W., Lee, S. M., Harburg, D. V., Krueger, N. A., Shin, J., Gamble, P., Cheng, H., Yu, S., et al. (2016) · Nature · doi:10.1038/nature16492 · Cited by 998 · see citing works
Dağdeviren, C., Su, Y., Joe, P., Yona, R., Liu, Y., Kim, Y., Huang, Y., Damadoran, A. R., Xia, J., Martin, L. W., et al. (2014) · Nature Communications · doi:10.1038/ncomms5496 · Cited by 987 · see citing works
Choi, S., Han, S. I., Jung, D., Hwang, H. J., Lim, C., Bae, S., Park, O. K., Tschabrunn, C. M., Lee, M., Bae, S. Y., et al. (2018) · Nature Nanotechnology · doi:10.1038/s41565-018-0226-8 · Cited by 984 · see citing works
Optoelectronically innervated soft prosthetic hand via stretchable optical waveguides
Zhao, H., O’Brien, K., Li, S., & Shepherd, R. F. (2016) · Science Robotics · doi:10.1126/scirobotics.aai7529 · Cited by 982 · see citing works
Conformal piezoelectric energy harvesting and storage from motions of the heart, lung, and diaphragm
Dagdeviren, C., Yang, B. D., Su, Y., Tran, P. L., Joe, P., Anderson, E., Xia, J., Doraiswamy, V., Dehdashti, B., Feng, X., et al. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1317233111 · Cited by 975 · see citing works
Electrolyte‐Gated Transistors for Organic and Printed Electronics
Kim, S. H., Hong, K., Xie, W., Lee, K. H., Zhang, S., Lodge, T. P., & Frisbie, C. D. (2013) · Advanced Materials · doi:10.1002/adma.201202790 · Cited by 957 · see citing works
Carbon-Nanotube-Embedded Hydrogel Sheets for Engineering Cardiac Constructs and Bioactuators
Shin, S. R., Jung, S. M., Zalabany, M., Kim, K., Zorlutuna, P., Kim, S. B., Nikkhah, M., Khabiry, M., Azize, M., Kong, J., et al. (2013) · ACS Nano · doi:10.1021/nn305559j · Cited by 946 · see citing works
Jaul, E., & Barron, J. (2017) · Frontiers in Public Health · doi:10.3389/fpubh.2017.00335 · Cited by 946 · see citing works
Ghamari, M. (2018) · International Journal of Biosensors & Bioelectronics · doi:10.15406/ijbsbe.2018.04.00125 · Cited by 945 · see citing works
NeuroGrid: recording action potentials from the surface of the brain
Khodagholy, D., Gelinas, J. N., Thesen, T., Doyle, W., Devinsky, O., Malliaras, G. G., & Buzsáki, G. (2015) · Nature Neuroscience · doi:10.1038/nn.3905 · Cited by 938 · see citing works
Park, J., Kim, M., Lee, Y., Lee, H. S., & Ko, H. (2015) · Science Advances · doi:10.1126/sciadv.1500661 · Cited by 936 · see citing works
Boutry, C. M., Negre, M., Jorda, M., Vardoulis, O., Chortos, A., Khatib, O., & Bao, Z. (2018) · Science Robotics · doi:10.1126/scirobotics.aau6914 · Cited by 931 · see citing works
Modeling and control of McKibben artificial muscle robot actuators
(2000) · IEEE Control Systems · doi:10.1109/37.833638 · Cited by 924 · see citing works
Park, J., Lee, Y., Hong, J., Ha, M., Jung, Y.-D., Lim, H., Kim, S. Y., & Ko, H. (2014) · ACS Nano · doi:10.1021/nn500441k · Cited by 915 · see citing works
Handbook of clinical neurology
Illis, L. S. (2013) · Spinal Cord · doi:10.1038/sc.2013.79 · Cited by 910 · see citing works
Monitoring of the central blood pressure waveform via a conformal ultrasonic device
Wang, C., Li, X., Hu, H., Zhang, L., Huang, Z., Lin, M., Zhang, Z., Yin, Z., Huang, B., Gong, H., et al. (2018) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0287-x · Cited by 895 · see citing works
Acceptance of Healthcare Robots for the Older Population: Review and Future Directions
Broadbent, E., Stafford, R., & MacDonald, B. (2009) · International Journal of Social Robotics · doi:10.1007/s12369-009-0030-6 · Cited by 887 · see citing works
Peng, X., Dong, K., Ye, C., Jiang, Y., Zhai, S., Cheng, R., Liu, D., Gao, X., Wang, J., & Wang, Z. L. (2020) · Science Advances · doi:10.1126/sciadv.aba9624 · Cited by 886 · see citing works
A skin-inspired organic digital mechanoreceptor
Tee, B. C.-K., Chortos, A., Berndt, A., Nguyen, A. K., Tom, A., McGuire, A., Lin, Z. C., Tien, K., Bae, W.-G., Wang, H., et al. (2015) · Science · doi:10.1126/science.aaa9306 · Cited by 882 · see citing works
Trung, T. Q., Ramasundaram, S., Hwang, B., & Lee, N. (2016) · Advanced Materials · doi:10.1002/adma.201504441 · Cited by 870 · see citing works
Soft material for soft actuators
Miriyev, A., Stack, K., & Lipson, H. (2017) · Nature Communications · doi:10.1038/s41467-017-00685-3 · Cited by 861 · see citing works
Mechanisms of sensory transduction in the skin
Lumpkin, E. A., & Caterina, M. J. (2007) · Nature · doi:10.1038/nature05662 · Cited by 860 · see citing works
Translational principles of deep brain stimulation
Kringelbach, M. L., Jenkinson, N., Owen, S. L. F., & Aziz, T. Z. (2007) · Nature Reviews Neuroscience · doi:10.1038/nrn2196 · Cited by 853 · see citing works
Whitesides, G. M. (2018) · Angewandte Chemie International Edition · doi:10.1002/anie.201800907 · Cited by 850 · see citing works
Emaminejad, S., Gao, W., Wu, E., Davies, Z. A., Yin Yin Nyein, H., Challa, S., Ryan, S. P., Fahad, H. M., Chen, K., Shahpar, Z., et al. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1701740114 · Cited by 839 · see citing works
Self-citationA transparent bending-insensitive pressure sensor
Lee, S., Reuveny, A., Reeder, J., Lee, S., Jin, H., Liu, Q., Yokota, T., Sekitani, T., Isoyama, T., Abe, Y., et al. (2016) · Nature Nanotechnology · doi:10.1038/nnano.2015.324 · Cited by 833 · see citing works
Smart wearable devices in cardiovascular care: Where we are and how to move forward
Bayoumy, K., Gaber, M., Elshafeey, A., Mhaimeed, O., Dineen, E. H., Marvel, F. A., Martin, S. S., Muse, E. D., Turakhia, M. P., Tarakji, K. G., et al. (2021) · Nature Reviews Cardiology · doi:10.1038/s41569-021-00522-7 · Cited by 829 · see citing works
Electrotactile and vibrotactile displays for sensory substitution systems
Kaczmarek, K. A., Webster, J. G., Bach-y-Rita, P., & Tompkins, W. J. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.68204 · Cited by 827 · see citing works
Wearable Haptic Systems for the Fingertip and the Hand: Taxonomy, Review, and Perspectives
Pacchierotti, C., Sinclair, S., Solazzi, M., Frisoli, A., Hayward, V., & Prattichizzo, D. (2017) · IEEE Transactions on Haptics · doi:10.1109/toh.2017.2689006 · Cited by 825 · see citing works
Bai, N., Wang, L., Wang, Q., Deng, J., Wang, Y., Lü, P., Huang, J., Li, G., Zhang, Y., Yang, J., et al. (2020) · Nature Communications · doi:10.1038/s41467-019-14054-9 · Cited by 816 · see citing works
Soft and elastic hydrogel-based microelectronics for localized low-voltage neuromodulation
Liu, Y., Liu, J., Chen, S., Lei, T., Kim, Y., Niu, S., Wang, H., Wang, X., Foudeh, A. M., Tok, J. B.-H., et al. (2019) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0335-6 · Cited by 811 · see citing works
Binodal, wireless epidermal electronic systems with in-sensor analytics for neonatal intensive care
Chung, H. U., Kim, B. H., Lee, J. Y., Lee, J., Xie, Z., Ibler, E. M., Lee, K., Banks, A., Jeong, J. Y., Kim, J., et al. (2019) · Science · doi:10.1126/science.aau0780 · Cited by 807 · see citing works
Personal Sensing: Understanding Mental Health Using Ubiquitous Sensors and Machine Learning
Mohr, D. C., Zhang, M., & Schueller, S. M. (2017) · Annual Review of Clinical Psychology · doi:10.1146/annurev-clinpsy-032816-044949 · Cited by 802 · see citing works
Soft, stretchable, fully implantable miniaturized optoelectronic systems for wireless optogenetics
Park, S. I., Brenner, D. S., Shin, G., Morgan, C. D., Copits, B. A., Chung, H. U., Pullen, M. Y., Noh, K. N., Davidson, S., Oh, S. J., et al. (2015) · Nature Biotechnology · doi:10.1038/nbt.3415 · Cited by 794 · see citing works
Brain-Controlled Interfaces: Movement Restoration with Neural Prosthetics
Schwartz, A. B., Cui, X. T., Weber, D. J., & Moran, D. W. (2006) · Neuron · doi:10.1016/j.neuron.2006.09.019 · Cited by 792 · see citing works
Ma, Y., Liu, N., Li, L., Hu, X., Zou, Z., Wang, J., Luo, S., & Gao, Y. (2017) · Nature Communications · doi:10.1038/s41467-017-01136-9 · Cited by 788 · see citing works
Zhu, M., Sun, Z., Zhang, Z., Shi, Q., He, T., Liu, H., Chen, T., & Lee, C. (2020) · Science Advances · doi:10.1126/sciadv.aaz8693 · Cited by 784 · see citing works
Polymeric Biomaterials for Medical Implants and Devices
Teo, A. J. T., Mishra, A., Park, I., Kim, Y.-J., Park, W.-T., & Yoon, Y.-J. (2016) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.5b00429 · Cited by 778 · see citing works
Bandodkar, A. J., Gutruf, P., Choi, J., Lee, K., Sekine, Y., Reeder, J. T., Jeang, W. J., Aranyosi, A. J., Lee, S. P., Model, J. B., et al. (2019) · Science Advances · doi:10.1126/sciadv.aav3294 · Cited by 761 · see citing works
A neural interface provides long-term stable natural touch perception
Tan, D. W., Schiefer, M. A., Keith, M. W., Anderson, J. R., Tyler, J., & Tyler, D. J. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3008669 · Cited by 751 · see citing works
Chronic, multisite, multielectrode recordings in macaque monkeys
Nicolelis, M. A. L., Dimitrov, D., Carmena, J. M., Crist, R., Lehew, G., Kralik, J. D., & Wise, S. P. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1934665100 · Cited by 740 · see citing works
Kozai, T. D. Y., Langhals, N. B., Patel, P. R., Deng, X., Zhang, H., Smith, K. L., Lahann, J., Kotov, N. A., & Kipke, D. R. (2012) · Nature Materials · doi:10.1038/nmat3468 · Cited by 721 · see citing works
Electronic skins and machine learning for intelligent soft robots
Shih, B., Shah, D., Li, J., Thuruthel, T. G., Park, Y.-L., Iida, F., Bao, Z., Kramer-Bottiglio, R., & Tolley, M. T. (2020) · Science Robotics · doi:10.1126/scirobotics.aaz9239 · Cited by 715 · see citing works
Kang, J., Tok, J. B.-H., & Bao, Z. (2019) · Nature Electronics · doi:10.1038/s41928-019-0235-0 · Cited by 706 · see citing works
Neuromechanics of Human Movement
Enoka, R. M. (2015) · Human Kinetics eBooks · doi:10.5040/9781492595632 · Cited by 702 · see citing works
Triboelectric nanogenerator sensors for soft robotics aiming at digital twin applications
Jin, T., Sun, Z., Li, L., Zhang, Q., Zhu, M., Zhang, Z., Yuan, G., Chen, T., Tian, Y., Hou, X., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-19059-3 · Cited by 695 · see citing works
Syringe-injectable electronics
Liu, J., Fu, T.-M., Cheng, Z., Hong, G., Zhou, T., Jin, L., Duvvuri, M., Jiang, Z., Kruskal, P., Xie, C., et al. (2015) · Nature Nanotechnology · doi:10.1038/nnano.2015.115 · Cited by 687 · see citing works
Stretchable Hydrogel Electronics and Devices
Lin, S., Yuk, H., Zhang, T., Parada, G. A., Koo, H., Yu, C., & Zhao, X. (2016) · Advanced Materials · doi:10.1002/adma.201504152 · Cited by 682 · see citing works
A soft robotic exosuit improves walking in patients after stroke
Awad, L. N., Bae, J., O’Donnell, K., De Rossi, S. M. M., Hendron, K., Sloot, L. H., Kudzia, P., Allen, S., Holt, K. G., Ellis, T. D., et al. (2017) · Science Translational Medicine · doi:10.1126/scitranslmed.aai9084 · Cited by 672 · see citing works
Materials and Structures toward Soft Electronics
Wang, C., Wang, C., Huang, Z., & Xu, S. H. (2018) · Advanced Materials · doi:10.1002/adma.201801368 · Cited by 671 · see citing works
Canales, A., Jia, X., Froriep, U. P., Koppes, R. A., Tringides, C. M., Selvidge, J., Lu, C., Hou, C., Wei, L., Fink, Y., et al. (2015) · Nature Biotechnology · doi:10.1038/nbt.3093 · Cited by 668 · see citing works
Zhang, F., Zang, Y., Huang, D., Di, C.-A., & Zhu, D. (2015) · Nature Communications · doi:10.1038/ncomms9356 · Cited by 668 · see citing works
A stretchable and biodegradable strain and pressure sensor for orthopaedic application
Boutry, C. M., Kaizawa, Y., Schroeder, B. C., Chortos, A., Legrand, A., Wang, Z., Chang, J., Fox, P., & Bao, Z. (2018) · Nature Electronics · doi:10.1038/s41928-018-0071-7 · Cited by 667 · see citing works
Meshworm: A Peristaltic Soft Robot With Antagonistic Nickel Titanium Coil Actuators
Seok, S., Onal, C. D., Cho, K.-J., Wood, R. J., Rus, D., & Kim, S. (2013) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2012.2204070 · Cited by 665 · see citing works
An epidermal patch for the simultaneous monitoring of haemodynamic and metabolic biomarkers
Sempionatto, J. R., Lin, M., Yin, L., De la paz, E., Pei, K., Sonsa-ard, T., de Loyola Silva, A. N., Khorshed, A. A., Zhang, F., Tostado, N., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00685-1 · Cited by 658 · see citing works
Ouyang, H., Liu, Z., Li, N., Shi, B., Zou, Y., Xie, F., Ma, Y., Li, Z. Y., Li, H., Zheng, Q., et al. (2019) · Nature Communications · doi:10.1038/s41467-019-09851-1 · Cited by 656 · see citing works
Neural recording and modulation technologies
Chen, R., Canales, A., & Anikeeva, P. (2017) · Nature Reviews Materials · doi:10.1038/natrevmats.2016.93 · Cited by 655 · see citing works
Yu, Y., Nassar, J., Xu, C., Min, J., Yang, Y., Dai, A., Doshi, R., Huang, A., Song, Y., Gehlhar, R., et al. (2020) · Science Robotics · doi:10.1126/scirobotics.aaz7946 · Cited by 655 · see citing works
Self-citationWireless battery-free wearable sweat sensor powered by human motion
Song, Y., Min, J., Yu, Y., Wang, H., Yang, Y., Zhang, H., & Gao, W. (2020) · Science Advances · doi:10.1126/sciadv.aay9842 · Cited by 652 · see citing works
Self-citationA Recipe for Soft Fluidic Elastomer Robots
Marchese, A. D., Katzschmann, R. K., & Rus, D. (2015) · Soft Robotics · doi:10.1089/soro.2014.0022 · Cited by 649 · see citing works
(1965) · Annals of Internal Medicine · doi:10.7326/0003-4819-63-4-738_2 · Cited by 648 · see citing works
Chronic recording capability of the Utah Intracortical Electrode Array in cat sensory cortex
Rousche, P. J., & Normann, R. A. (1998) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(98)00031-4 · Cited by 646 · see citing works
Electroconductive hydrogels: Synthesis, characterization and biomedical applications
Guiseppi-Elie, A. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2009.12.052 · Cited by 646 · see citing works
Flexible polyimide-based intracortical electrode arrays with bioactive capability
Rousche, P. J., Pellinen, D. S., Pivin, D. P., Williams, J. C., Vetter, R. J., & Kipke, D. R. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.914800 · Cited by 644 · see citing works
Macroporous Nanowire Nanoelectronic Scaffolds for Synthetic Tissues
Jia Liu, B., Dvir, T., Jin, L., Tsui, J. H., Qing, Q., Suo, Z., Langer, R., Kohane, D. S., Lieber, C. M., & Tian, B. (2012) · Digital Access to Scholarship at Harvard (DASH) (Harvard University) · Cited by 642 · see citing works
Maynard, E. M., Nordhausen, C. T., & Normann, R. A. (1997) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(96)95176-0 · Cited by 640 · see citing works
Nanomesh pressure sensor for monitoring finger manipulation without sensory interference
Lee, S., Franklin, S., Hassani, F. A., Yokota, T., Nayeem, M. O. G., Wang, Y., Leib, R., Cheng, G., Franklin, D. W., & Someya, T. (2020) · Science · doi:10.1126/science.abc9735 · Cited by 640 · see citing works
Xu, L., Gutbrod, S. R., Bonifas, A. P., Su, Y., Sulkin, M. S., Lu, N., Chung, H.-J., Jang, K.-I., Liu, Z., Ying, M., et al. (2014) · Nature Communications · doi:10.1038/ncomms4329 · Cited by 634 · see citing works
Artificial multimodal receptors based on ion relaxation dynamics
You, I., Mackanic, D. G., Matsuhisa, N., Kang, J., Kwon, J., Beker, L., Mun, J., Suh, W., Kim, T. Y., Tok, J. B.-H., et al. (2020) · Science · doi:10.1126/science.aba5132 · Cited by 632 · see citing works
Active tactile exploration using a brain–machine–brain interface
O’Doherty, J. E., Lebedev, M. A., Ifft, P. J., Zhuang, K. Z., Shokur, S., Bleuler, H., & Nicolelis, M. A. L. (2011) · Nature · doi:10.1038/nature10489 · Cited by 629 · see citing works
Moradi, S., Qiao, N., Stefanini, F., & Indiveri, G. (2017) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2017.2759700 · Cited by 627 · see citing works
Pu, X., Guo, H., Chen, J., Wang, X., Xi, Y., Hu, C., & Wang, Z. L. (2017) · Science Advances · doi:10.1126/sciadv.1700694 · Cited by 627 · see citing works
Significance of Nanomaterials in Wearables: A Review on Wearable Actuators and Sensors
Jayathilaka, W. A. D. M., Qi, K., Qin, Y., Chinnappan, A., Serrano‐García, W., Baskar, C., Wang, H., He, J., Cui, S., Thomas, S. W., et al. (2019) · Advanced Materials · doi:10.1002/adma.201805921 · Cited by 627 · see citing works
Cortical activity during motor execution, motor imagery, and imagery-based online feedback
Miller, K. J., Schalk, G., Fetz, E. E., den Nijs, M., Ojemann, J. G., & Rao, R. P. N. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0913697107 · Cited by 622 · see citing works
Flexible Hybrid Electronics for Digital Healthcare
Ma, Y., Zhang, Y., Cai, S., Han, Z., Liu, X., Wang, F., Cao, Y., Wang, Z., Li, H., Chen, Y., et al. (2020) · Advanced Materials · doi:10.1002/adma.201902062 · Cited by 620 · see citing works
Stretchable and self-healing polymers and devices for electronic skin
Benight, S. J., Wang, C., Tok, J. B. H., & Bao, Z. (2013) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2013.08.001 · Cited by 617 · see citing works
Wearable Microfluidic Diaphragm Pressure Sensor for Health and Tactile Touch Monitoring
Gao, Y., Ota, H., Schaler, E. W., Chen, K., Zhao, A., Gao, W., Fahad, H. M., Leng, Y., Zheng, A., Xiong, F., et al. (2017) · Advanced Materials · doi:10.1002/adma.201701985 · Cited by 614 · see citing works
Self-citationA wireless body area sensor network based on stretchable passive tags
Niu, S., Matsuhisa, N., Beker, L., Li, J., Wang, S., Wang, J., Jiang, Y., Yan, X., Yun, Y., Burnett, W., et al. (2019) · Nature Electronics · doi:10.1038/s41928-019-0286-2 · Cited by 601 · see citing works
Tissue–electronics interfaces: from implantable devices to engineered tissues
Feiner, R., & Dvir, T. (2017) · Nature Reviews Materials · doi:10.1038/natrevmats.2017.76 · Cited by 595 · see citing works
Feig, V. R., Tran, H., Lee, M., & Bao, Z. (2018) · Nature Communications · doi:10.1038/s41467-018-05222-4 · Cited by 585 · see citing works
Zhang, L., Kumar, K. S., He, H., Cai, C. J., He, X., Gao, H., Yue, S., Li, C., Seet, R. C.-S., Ren, H., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-18503-8 · Cited by 574 · see citing works
Skin-inspired electronic devices
Chortos, A., & Bao, Z. (2014) · Materials Today · doi:10.1016/j.mattod.2014.05.006 · Cited by 571 · see citing works
Choi, S., Park, J., Hyun, W., Kim, J., Kim, J., Lee, Y. B., Song, C., Hwang, H. J., Kim, J. H., Hyeon, T., et al. (2015) · ACS Nano · doi:10.1021/acsnano.5b02790 · Cited by 568 · see citing works
Wirelessly powered, fully internal optogenetics for brain, spinal and peripheral circuits in mice
Montgomery, K. L., Yeh, A. J., Ho, J. S., Tsao, V., Mohan Iyer, S., Grosenick, L., Ferenczi, E. A., Tanabe, Y., Deisseroth, K., Delp, S. L., et al. (2015) · Nature Methods · doi:10.1038/nmeth.3536 · Cited by 565 · see citing works
Park, D.-W., Schendel, A. A., Mikael, S., Brodnick, S. K., Richner, T. J., Ness, J. P., Hayat, M. R., Atry, F., Frye, S. T., Pashaie, R., et al. (2014) · Nature Communications · doi:10.1038/ncomms6258 · Cited by 565 · see citing works
Soft magnetic skin for super-resolution tactile sensing with force self-decoupling
Yan, Y., Hu, Z., Yang, Z., Yuan, W., Song, C., Pan, J., & Shen, Y. (2021) · Science Robotics · doi:10.1126/scirobotics.abc8801 · Cited by 564 · see citing works
Graphene Textile Strain Sensor with Negative Resistance Variation for Human Motion Detection
Yang, Z., Pang, Y., Han, X.-L., Yang, Y., Ling, J., Jian, M., Zhang, Y., Yang, Y., & Ren, T.-L. (2018) · ACS Nano · doi:10.1021/acsnano.8b03391 · Cited by 563 · see citing works
Wireless Recording in the Peripheral Nervous System with Ultrasonic Neural Dust
Seo, D., Neely, R. M., Shen, K., Singhal, U., Alon, E., Rabaey, J. M., Carmena, J. M., & Maharbiz, M. M. (2016) · Neuron · doi:10.1016/j.neuron.2016.06.034 · Cited by 557 · see citing works
Three-dimensional integrated stretchable electronics
Huang, Z., Hao, Y., Li, Y., Hu, H., Wang, C., Nomoto, A., Pan, T., Gu, Y., Chen, Y., Zhang, T., et al. (2018) · Nature Electronics · doi:10.1038/s41928-018-0116-y · Cited by 551 · see citing works
Flexible suspended gate organic thin-film transistors for ultra-sensitive pressure detection
Zang, Y., Zhang, F., Huang, D., Gao, X., Di, C.-A., & Zhu, D. (2015) · Nature Communications · doi:10.1038/ncomms7269 · Cited by 548 · see citing works
Kuzum, D., Takano, H., Shim, E., Reed, J. C., Juul, H., Richardson, A. G., de Vries, J., Bink, H., Dichter, M. A., Lucas, T. H., et al. (2014) · Nature Communications · doi:10.1038/ncomms6259 · Cited by 546 · see citing works
Deyo, R. A., Walsh, N. E., Martin, D. C., Schoenfeld, L. S., & Ramamurthy, S. (1990) · New England Journal of Medicine · doi:10.1056/nejm199006073222303 · Cited by 532 · see citing works
Neuromuscular electrical stimulation in neurorehabilitation
Sheffler, L. R., & Chae, J. (2007) · Muscle & Nerve · doi:10.1002/mus.20758 · Cited by 529 · see citing works
Winters, J. M., & Stark, L. (1985) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1985.325498 · Cited by 526 · see citing works
Yu, K. J., Kuzum, D., Hwang, S.-W., Kim, B. H., Juul, H., Kim, N. H., Won, S. M., Chiang, K., Trumpis, M., Richardson, A. G., et al. (2016) · Nature Materials · doi:10.1038/nmat4624 · Cited by 523 · see citing works
Wearable thermoelectrics for personalized thermoregulation
Hong, S., Gu, Y., Seo, J. K., Wang, J., Liu, P., Meng, Y. S., Xu, S., & Chen, R. (2019) · Science Advances · doi:10.1126/sciadv.aaw0536 · Cited by 522 · see citing works
Automatic design of fiber-reinforced soft actuators for trajectory matching
Connolly, F., Walsh, C. J., & Bertoldi, K. (2016) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1615140114 · Cited by 519 · see citing works
Face Recognition Performance: Role of Demographic Information
Klare, B. F., Burge, M. J., Klontz, J. C., Vorder Bruegge, R. W., & Jain, A. K. (2012) · IEEE Transactions on Information Forensics and Security · doi:10.1109/tifs.2012.2214212 · Cited by 516 · see citing works
Machine-knitted washable sensor array textile for precise epidermal physiological signal monitoring
Fan, W., He, Q., Meng, K., Tan, X., Zhou, Z., Zhang, G., Yang, J., & Wang, Z. L. (2020) · Science Advances · doi:10.1126/sciadv.aay2840 · Cited by 516 · see citing works
Next-generation probes, particles, and proteins for neural interfacing
Rivnay, J., Wang, H., Fenno, L., Deisseroth, K., & Malliaras, G. G. (2017) · Science Advances · doi:10.1126/sciadv.1601649 · Cited by 514 · see citing works
Dagdeviren, C., Shi, Y., Joe, P., Ghaffari, R., Balooch, G., Usgaonkar, K., Gur, O., Tran, P. L., Crosby, J. R., Meyer, M., et al. (2015) · Nature Materials · doi:10.1038/nmat4289 · Cited by 513 · see citing works
Ultra-sensitive and resilient compliant strain gauges for soft machines
Araromi, O. A., Graule, M. A., Dorsey, K. L., Castellanos, S., Foster, J. R., Hsu, W.-H., Passy, A. E., Vlassak, J. J., Weaver, J. C., Walsh, C. J., et al. (2020) · Nature · doi:10.1038/s41586-020-2892-6 · Cited by 513 · see citing works
A Highly Elastic, Capacitive Strain Gauge Based on Percolating Nanotube Networks
Cohen, D. J., Mitra, D., Peterson, K., & Maharbiz, M. M. (2012) · Nano Letters · doi:10.1021/nl204052z · Cited by 501 · see citing works
Materials for flexible bioelectronic systems as chronic neural interfaces
Song, E., Li, J., Won, S. M., Bai, W., & Rogers, J. A. (2020) · Nature Materials · doi:10.1038/s41563-020-0679-7 · Cited by 498 · see citing works
Design and control of a bio-inspired soft wearable robotic device for ankle–foot rehabilitation
Park, Y.-L., Chen, B.-R., Pérez-Arancibia, N. O., Young, D., Stirling, L., Wood, R. J., Goldfield, E. C., & Nagpal, R. (2014) · Bioinspiration & Biomimetics · doi:10.1088/1748-3182/9/1/016007 · Cited by 497 · see citing works
Recent Progress on Stretchable Electronic Devices with Intrinsically Stretchable Components
Trung, T. Q., & Lee, N. (2017) · Advanced Materials · doi:10.1002/adma.201603167 · Cited by 497 · see citing works
A review on inkjet printing of nanoparticle inks for flexible electronics
Nayak, L., Mohanty, S., Nayak, S. K., & Ramadoss, A. (2019) · Journal of Materials Chemistry C · doi:10.1039/c9tc01630a · Cited by 497 · see citing works
Koo, J., MacEwan, M. R., Kang, S.-K., Won, S. M., Stephen, M., Gamble, P., Xie, Z., Yan, Y., Chen, Y.-Y., Shin, J., et al. (2018) · Nature Medicine · doi:10.1038/s41591-018-0196-2 · Cited by 496 · see citing works
Wireless Optofluidic Systems for Programmable In Vivo Pharmacology and Optogenetics
Jeong, J., McCall, J. G., Shin, G., Zhang, Y., Al‐Hasani, R., Kim, M. K., Li, S., Sim, J. Y., Jang, K., Shi, Y., et al. (2015) · Cell · doi:10.1016/j.cell.2015.06.058 · Cited by 493 · see citing works
Stretchable distributed fiber-optic sensors
Bai, H., Li, S., Barreiros, J., Tu, Y., Pollock, C. R., & Shepherd, R. F. (2020) · Science · doi:10.1126/science.aba5504 · Cited by 490 · see citing works
Ortiz-Catalan, M., Håkansson, B., & Brånemark, R. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3008933 · Cited by 484 · see citing works
Investigation of Cortisol Dynamics in Human Sweat Using a Graphene-Based Wireless mHealth System
Torrente-Rodríguez, R. M., Tu, J., Yang, Y., Min, J., Wang, M., Song, Y., Yu, Y., Xu, C., Ye, C., IsHak, W. W., et al. (2020) · Matter · doi:10.1016/j.matt.2020.01.021 · Cited by 479 · see citing works
Self-citationSkin-inspired quadruple tactile sensors integrated on a robot hand enable object recognition
Li, G., Liu, S., Wang, L., & Zhu, R. (2020) · Science Robotics · doi:10.1126/scirobotics.abc8134 · Cited by 477 · see citing works
Jinno, H., Fukuda, K., Xu, X., Park, S., Suzuki, Y., Koizumi, M., Yokota, T., Osaka, I., Takimiya, K., & Someya, T. (2017) · Nature Energy · doi:10.1038/s41560-017-0001-3 · Cited by 476 · see citing works
Super-elastic ferroelectric single-crystal membrane with continuous electric dipole rotation
Dong, G., Li, S., Yao, M., Zhou, Z., Zhang, Y.-Q., Han, X., Luo, Z., Yao, J., Peng, B., Hu, Z., et al. (2019) · Science · doi:10.1126/science.aay7221 · Cited by 475 · see citing works
Transparent, Optical, Pressure‐Sensitive Artificial Skin for Large‐Area Stretchable Electronics
Ramuz, M. P., Tee, B. C. K., Tok, J. B. ‐., & Bao, Z. (2012) · Advanced Materials · doi:10.1002/adma.201200523 · Cited by 474 · see citing works
Exo-Glove: A Wearable Robot for the Hand with a Soft Tendon Routing System
In, H., Kang, B. B., Sin, M., & Cho, K.-J. (2015) · IEEE Robotics & Automation Magazine · doi:10.1109/mra.2014.2362863 · Cited by 473 · see citing works
Instant tough bonding of hydrogels for soft machines and electronics
Wirthl, D., Pichler, R., Drack, M., Kettlguber, G., Moser, R., Gerstmayr, R., Hartmann, F., Bradt, E., Kaltseis, R., Siket, C. M., et al. (2017) · Science Advances · doi:10.1126/sciadv.1700053 · Cited by 471 · see citing works
A transverse intrafascicular multichannel electrode (TIME) to interface with the peripheral nerve
Boretius, T., Badia, J., Pascual-Font, A., Schuettler, M., Navarro, X., Yoshida, K., & Stieglitz, T. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.05.010 · Cited by 470 · see citing works
Strain-programmable fiber-based artificial muscle
Kanik, M., Orguc, S., Varnavides, G., Kim, J., Benavides, T., Gonzalez, D., Akintilo, T., Tasan, C. C., Chandrakasan, A. P., Fink, Y., et al. (2019) · Science · doi:10.1126/science.aaw2502 · Cited by 468 · see citing works
Sensory feedback in upper limb prosthetics
Antfolk, C., D’Alonzo, M., Rosén, B., Lundborg, G., Sebelius, F., & Cipriani, C. (2013) · Expert Review of Medical Devices · doi:10.1586/erd.12.68 · Cited by 466 · see citing works
An octopus-bioinspired solution to movement and manipulation for soft robots
Calisti, M., Giorelli, M., Levy, G., Mazzolai, B., Hochner, B., Laschi, C., & Dario, P. (2011) · Bioinspiration & Biomimetics · doi:10.1088/1748-3182/6/3/036002 · Cited by 465 · see citing works
Wang, M., Luo, Y., Wang, T., Wan, C., Pan, L., Pan, S., He, K., Neo, A., & Chen, X. (2021) · Advanced Materials · doi:10.1002/adma.202003014 · Cited by 451 · see citing works
A biologically inspired soft exosuit for walking assistance
Asbeck, A. T., De Rossi, S. M. M., Holt, K. G., & Walsh, C. J. (2015) · The International Journal of Robotics Research · doi:10.1177/0278364914562476 · Cited by 450 · see citing works
Zheng, Q., Zhang, H., Shi, B., Xue, X., Liu, Z., Jin, Y., Ma, Y., Zou, Y., Wang, X., An, Z., et al. (2016) · ACS Nano · doi:10.1021/acsnano.6b02693 · Cited by 449 · see citing works
Sensitive Wearable Temperature Sensor with Seamless Monolithic Integration
Shin, J., Jeong, B., Kim, J., Nam, V. B., Yoon, Y., Jung, J., Hong, S., Lee, H., Eom, H., Yeo, J., et al. (2020) · Advanced Materials · doi:10.1002/adma.201905527 · Cited by 449 · see citing works
Piech, D. K., Johnson, B. C., Shen, K., Ghanbari, M. M., Li, K. Y., Neely, R. M., Kay, J. E., Carmena, J. M., Maharbiz, M. M., & Muller, R. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-020-0518-9 · Cited by 442 · see citing works
Won, P., Park, J. J., Lee, T., Ha, I., Han, S., Choi, M., Lee, J., Hong, S., Cho, K., & Ko, S. H. (2019) · Nano Letters · doi:10.1021/acs.nanolett.9b02014 · Cited by 439 · see citing works
An artificial neural tactile sensing system
Chun, S., Kim, J.-S., Yoo, Y., Choi, Y. I., Jung, S. J., Jang, D., Lee, G., Song, K., Nam, K. S., Youn, I., et al. (2021) · Nature Electronics · doi:10.1038/s41928-021-00585-x · Cited by 437 · see citing works
A soft neuroprosthetic hand providing simultaneous myoelectric control and tactile feedback
Gu, G., Zhang, N., Xu, H., Lin, S., Yu, Y., Chai, G., Ge, L., Yang, H., Shao, Q., Sheng, X., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00767-0 · Cited by 431 · see citing works
Surface EMG in advanced hand prosthetics
Castellini, C., & van der Smagt, P. (2008) · Biological Cybernetics · doi:10.1007/s00422-008-0278-1 · Cited by 429 · see citing works
Prosthesis with neuromorphic multilayered e-dermis perceives touch and pain
Osborn, L. E., Dragomir, A., Betthauser, J. L., Hunt, C. L., Nguyen, H. H., Kaliki, R. R., & Thakor, N. V. (2018) · Science Robotics · doi:10.1126/scirobotics.aat3818 · Cited by 427 · see citing works
An, B. W., Heo, S., Ji, S., Bien, F., & Park, J.-U. (2018) · Nature Communications · doi:10.1038/s41467-018-04906-1 · Cited by 426 · see citing works
Flagged first, then by citations
Research works printed but not linked: 27
- Coco D. L., 2016, Vasc Health Risk Manage, 12, 105
- Ashley M. J., 2012, Cerebrum, 2012, 8
- W.‐K.Song H.‐Y.Lee J.‐S.Kim Y.‐S.Yoon Z.Bien inProc. of the 20th Annual Int. Conf. of the IEEE Engineering in Medicine and Biology Society. Vol. 20 Biomedical Engineering Towards the Year 2000 and Beyond (Cat. No. 98CH36286) IEEE Piscataway NJ1998 pp.2682–2685.
- Clippinger F. W., 1974, Bull. Prosthet. Res., 10, 247
- Gu G., 2021, Nat. Biomed. Eng.
- Farina D., 2021, Nat. Biomed. Eng.
- Jung P.‐G., 2015, IEEE Trans Ind. Inf., 11, 485
- Ghamari M., 2018, Int. J. Biosens. Bioelectron., 4, 195
- Furui A., 2019, Sci. Rob., 4, 31
- Hahne J. M., 2018, Sci. Rob., 3, 19
- Guo L., 2012, IEEE Trans. Biomed. Circuits Syst., 7, 1
- Won S. M., 2021, Nat. Biomed. Eng.
- 10.1038/nature16492 · DOI · Paper page
- Dweiri Y. M., 2016, J. Visualized Exp., 54388
- Boretius T., 2012, 2012 4th IEEE RAS EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob), 282
- Yang G., 2018, IEEE J. Transl. Eng. Health Med., 6, 1
- Yap H. K., 2015, 2015 IEEE Int. Conf. on Robotics and Automation (ICRA), 4967
- Klute G. K., 1999, 1999 IEEE/ASME Int. Conf. on Advanced Intelligent Mechatronics (Cat. No.99TH8399), 221
- Marchese A. D., 2014, 2014 IEEE Int. Conf. on Robotics and Automation (ICRA), 2189
- Morrow J., 2016, 2016 IEEE Int. Conf. on Robotics and Automation (ICRA), 5024
- Park Y.‐L., 2014, 2014 IEEE Int. Conf. on Robotics and Automation (ICRA), 4805
- Arjun A., 2016, 2016 IEEE Int. Conf. on Automation Science and Engineering (CASE), 910
- Zamanian A. H., 2018, Am. Soc. Mech. Eng. Digital Collect., 1, V001T12A006
- Muthukumarana S., 2020, Proc. of the 2020 CHI Conf. on Human Factors in Computing Systems, 1
- Withana A., 2018, Proc. of the 31st Annual ACM Symp. on User Interface Software and Technology, 365
- Bern J. M., 2020, 2020 3rd IEEE Int. Conf. on Soft Robotics (RoboSoft), 417
- Wang M., 2021, Trends Chem.
Cited by
Sorted by citations
Technology Roadmap for Flexible Sensors
Luo, Y., Abidian, M. R., Ahn, J., Akinwande, D., Andrews, A. M., Antonietti, M., Bao, Z., Magnus Berggren, A., Berkey, C. A., Bettinger, C. J., et al. (2023) · ACS Nano · doi:10.1021/acsnano.2c12606 · Cited by 1,419 · see citing works
Self-citationAdvances in graphene-based flexible and wearable strain sensors
Chen, H., Zhuo, F., Zhou, J., Liu, Y., Zhang, J., Dong, S., Liu, X., Elmarakbi, A., Duan, H., & Fu, Y. (2023) · Chemical Engineering Journal · doi:10.1016/j.cej.2023.142576 · Cited by 386 · see citing works
Organic optoelectronic synapse based on photon-modulated electrochemical doping
Chen, K., Hu, H., Song, I., et al. (2023) · Nature Photonics · doi:10.1038/s41566-023-01232-x · Cited by 296 · see citing works
Flexible Energy Storage Devices to Power the Future
He, J., Cao, L., Cui, J., Fu, G., Jiang, R., Xu, X., & Guan, C. (2023) · Advanced Materials · doi:10.1002/adma.202306090 · Cited by 291 · see citing works
Soft Sensors and Actuators for Wearable Human–Machine Interfaces
Park, J., Lee, Y., Cho, S., Choe, A., Yeom, J., Ro, Y. G., Kim, J., Kang, D., Lee, S., & Ko, H. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00356 · Cited by 282 · see citing works
Fatigue-free artificial ionic skin toughened by self-healable elastic nanomesh
Wang, J.-Q., Wu, B.-H., Wei, P., Sun, S.-T., & Wu, P.-Y. (2022) · Nature Communications · doi:10.1038/s41467-022-32140-3 · Cited by 239 · see citing works
Li, W., Liu, J., Wei, J., Yang, Z., Ren, C., & Li, B. (2023) · Advanced Functional Materials · doi:10.1002/adfm.202213485 · Cited by 235 · see citing works
Flexible Pressure Sensors in Human–Machine Interface Applications
Xu, C., Chen, J., Zhu, Z., Liu, M., Lan, R., Chen, X., Tang, W., Zhang, Y., & Li, H. (2023) · Small · doi:10.1002/smll.202306655 · Cited by 198 · see citing works
Kim, S. W., Lee, J., Ko, H. J., et al. (2024) · ACS Nano · doi:10.1021/acsnano.3c09016 · Cited by 182 · see citing works
Low-dimensional nanostructures for monolithic 3D-integrated flexible and stretchable electronics
Hua, Q., & Shen, G. (2024) · Chemical Society Reviews · doi:10.1039/d3cs00918a · Cited by 182 · see citing works
Zhang, Y., Dai, Y., Xia, F., & Zhang, X. (2022) · Nano Energy · doi:10.1016/j.nanoen.2022.107977 · Cited by 177 · see citing works
Skin-inspired, sensory robots for electronic implants
Zhang, L., Xing, S., Yin, H., Weisbecker, H., Tran, H. T., Guo, Z., Han, T., Wang, Y., Liu, Y., Wu, Y., et al. (2024) · Nature Communications · doi:10.1038/s41467-024-48903-z · Cited by 188 · see citing works
Yang, H., Li, J., Xiao, X., Wang, J., Li, Y., Li, K., Li, Z., Yang, H., Wang, Q., Yang, J., et al. (2022) · Nature Communications · doi:10.1038/s41467-022-33021-5 · Cited by 181 · see citing works
Wearable and Implantable Soft Robots
Yin, S., Yao, D. R., Song, Y., Heng, W., Ma, X., Han, H., & Gao, W. F. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.4c00513 · Cited by 179 · see citing works
Self-citationToward an AI Era: Advances in Electronic Skins
Fu, X., Cheng, W., Wan, G., Yang, Z., & Tee, B. C. K. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.4c00049 · Cited by 172 · see citing works
Advances in flexible sensors for intelligent perception system enhanced by artificial intelligence
Niu, H., Yin, F., Kim, E., Wang, W., Yoon, D., Wang, C., Liang, J., Li, Y., & Kim, N. (2023) · InfoMat · doi:10.1002/inf2.12412 · Cited by 169 · see citing works
Mechanically-Guided 3D Assembly for Architected Flexible Electronics
Bo, R., Xu, S., Yang, Y., & Zhang, Y. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00335 · Cited by 172 · see citing works
Chen, S., Fan, S., Qiao, Z., Wu, Z., Lin, B., Li, Z., Riegler, M. A., Wong, M. Y. H., Opheim, A. I., Korostynska, O., et al. (2025) · Advanced Materials · doi:10.1002/adma.202500412 · Cited by 189 · see citing works
Recent Advances in Flexible Sensors and Their Applications
Zazoum, B., Batoo, K. M., & Khan, M. A. A. (2022) · Sensors · doi:10.3390/s22124653 · Cited by 148 · see citing works
Soft robotic grippers: A review on technologies, materials, and applications
AboZaid, Y. A., Aboelrayat, M. T., Fahim, I. S., & Radwan, A. G. (2024) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2024.115380 · Cited by 141 · see citing works
Conformal in-ear bioelectronics for visual and auditory brain-computer interfaces
Wang, Z., Shi, N., Zhang, Y., Zheng, N., Li, H., Jiao, Y., Cheng, J., Wang, Y., Zhang, X., Chen, Y., et al. (2023) · Nature Communications · doi:10.1038/s41467-023-39814-6 · Cited by 141 · see citing works
Fibres—threads of intelligence—enable a new generation of wearable systems
Dang, C., Wang, Z., Hughes‐Riley, T., Dias, T., Qian, S., Wang, Z., Wang, X., Liu, M., Yu, S., Liu, R., et al. (2024) · Chemical Society Reviews · doi:10.1039/d4cs00286e · Cited by 137 · see citing works
Guo, X., Sun, Z., Zhu, Y., & Lee, C. (2024) · Advanced Materials · doi:10.1002/adma.202406778 · Cited by 125 · see citing works
Recent progress of bio-based smart wearable sensors for healthcare applications
Banitaba, S. N., Khademolqorani, S., Jadhav, V. V., Chamanehpour, E., Mishra, Y. K., Mostafavi, E., & Kaushik, A. K. (2023) · Materials Today Electronics · doi:10.1016/j.mtelec.2023.100055 · Cited by 124 · see citing works
Environment‐Tolerant Conductive Eutectogels for Multifunctional Sensing
Guo, B., Yao, M., Chen, S., Yu, Q., Liang, L., Yu, C., Liu, M., Hao, H., Zhang, H., Yao, F., et al. (2024) · Advanced Functional Materials · doi:10.1002/adfm.202315656 · Cited by 119 · see citing works
Imperceptible, designable, and scalable braided electronic cord
Chen, M., Ouyang, J., Jian, A., Liu, J., Li, P., Hao, Y., Gong, Y., Hu, J., Zhou, J., Wang, R., et al. (2022) · Nature Communications · doi:10.1038/s41467-022-34918-x · Cited by 118 · see citing works
“The concept of multifunctional fi bers 18,19 and fl exible electronic sensors 20 – 26 with fl exible mechanics, comfort, and embedded machine learning algorithms 27 poses a possible solution to address the afore-mentioned dif fi culties.”
BackgroundNew Carbon Materials for Multifunctional Soft Electronics
Xue, J., Liu, D., Li, D., Hong, T., Li, C., Zhu, Z., Sun, Y., Gao, X., Guo, L., Shen, X., et al. (2024) · Advanced Materials · doi:10.1002/adma.202312596 · Cited by 117 · see citing works
MXene-Enabled Self-Adaptive Hydrogel Interface for Active Electroencephalogram Interactions
Luo, J., Sun, C., Chang, B., Jing, Y., Li, K., Li, Y., Zhang, Q., Wang, H., & Hou, C. (2022) · ACS Nano · doi:10.1021/acsnano.2c08961 · Cited by 116 · see citing works
Guo, S., Patel, S. B., Wang, J., Yu, Z., Qu, H., Zhang, S., Yu, K., Liu, S., Koh, J. J., Koh, X. Q., et al. (2025) · Science Advances · doi:10.1126/sciadv.adw5991 · Cited by 117 · see citing works
Soft Materials and Devices Enabling Sensorimotor Functions in Soft Robots.
Su, J.-T., He, K., Li, Y.-Z., Tu, J., & Chen, X.-D. (2025) · Chemical Reviews · doi:10.1021/acs.chemrev.4c00906 · Cited by 106 · see citing works
Reversible Wet‐Adhesive and Self‐Healing Conductive Composite Elastomer of Liquid Metal
Pei, D., Yu, S., Liu, P., et al. (2022) · Advanced Functional Materials · doi:10.1002/adfm.202204257 · Cited by 109 · see citing works
Nanomaterials for Flexible Neuromorphics
Ding, G., Li, H., Zhao, J., Zhou, K., Zhai, Y., Lv, Z., Zhang, M., Yan, Y., Han, S., & Zhou, Y. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.4c00369 · Cited by 107 · see citing works
Metaverse Wearables for Immersive Digital Healthcare: A Review
Kim, K., Yang, H., Lee, J.-H., & Lee, W. G. (2023) · Advanced Science · doi:10.1002/advs.202303234 · Cited by 105 · see citing works
Advances in Flexible Magnetosensitive Materials and Devices for Wearable Electronics
Yang, H., Li, S., Wu, Y., Bao, X., Xiang, Z., Xie, Y., Pan, L., Chen, J., Liu, Y., & Li, R. (2024) · Advanced Materials · doi:10.1002/adma.202311996 · Cited by 99 · see citing works
Shen, T., Liu, S., Yue, X., et al. (2023) · Advanced Composites and Hybrid Materials · doi:10.1007/s42114-023-00701-9 · Cited by 93 · see citing works
Response Regulation for Epidermal Fabric Strain Sensors via Mechanical Strategy
Bai, Y., Yin, L., Hou, C., Zhou, Y., Zhang, F., Xu, Z., Li, K., & Huang, Y. (2023) · Advanced Functional Materials · doi:10.1002/adfm.202214119 · Cited by 89 · see citing works
A programmable magnetoelastic sensor array for self-powered human–machine interface
Xu, J. H., Tat, T., Zhao, X., Zhou, Y., Ngo, D., Xiao, X., & Chen, J. (2022) · Applied Physics Reviews · doi:10.1063/5.0094289 · Cited by 92 · see citing works
Neural interfaces: Bridging the brain to the world beyond healthcare
Xu, S., Liu, Y., Lee, H., & Li, W. (2024) · Exploration · doi:10.1002/exp.20230146 · Cited by 96 · see citing works
Zhou, Q., Ji, B., Hu, F., Dai, Z., Ding, S., Yang, H., Zhong, J., Qiao, Y., Zhou, J., Luo, J., et al. (2022) · Advanced Functional Materials · doi:10.1002/adfm.202208120 · Cited by 86 · see citing works
Su, G., Wang, N., Liu, Y., Zhang, R., Li, Z., Deng, Y., & Tang, B. Z. (2024) · Advanced Materials · doi:10.1002/adma.202400085 · Cited by 87 · see citing works
Fan, J., Yang, R., Du, Y.-Q., Wang, F., Wang, L.-B., Yang, J., & Zhou, A.-G. (2024) · Nano Energy · doi:10.1016/j.nanoen.2024.109999 · Cited by 81 · see citing works
Advanced polymer materials‐based electronic skins for tactile and non‐contact sensing applications
Yin, F., Niu, H., Kim, E., Shin, Y. K., Li, Y., & Kim, N. (2023) · InfoMat · doi:10.1002/inf2.12424 · Cited by 85 · see citing works
Flexible tactile sensors with biomimetic microstructures: Mechanisms, fabrication, and applications
Zhang, Z., Liu, G., Li, Z., Zhang, W., & Meng, Q. (2023) · Advances in Colloid and Interface Science · doi:10.1016/j.cis.2023.102988 · Cited by 83 · see citing works
Pei, X., Sun, M., Wang, J., Bai, J., Bo, X., & Zhou, M. (2022) · Small · doi:10.1002/smll.202205061 · Cited by 80 · see citing works
Nam, M., Chang, J., Kim, H., Son, Y. H., Jeon, Y., Kwon, J. H., & Choi, K. C. (2024) · npj Flexible Electronics · doi:10.1038/s41528-024-00303-5 · Cited by 82 · see citing works
Xiong, W., Zhang, F., Qu, S., Yin, L., Li, K., & Huang, Y. (2024) · Nature Communications · doi:10.1038/s41467-024-49864-z · Cited by 79 · see citing works
Xie, F. (2024) · Carbohydrate Polymers · doi:10.1016/j.carbpol.2024.122116 · Cited by 77 · see citing works
You, L., Zheng, Z., Xu, W., et al. (2024) · International Journal of Biological Macromolecules · doi:10.1016/j.ijbiomac.2024.130439 · Cited by 78 · see citing works
Liquid metal flexible electronics: Past, present, and future
Chen, S., Cui, Z., Wang, H., Wang, X., & Liu, J. (2023) · Applied Physics Reviews · doi:10.1063/5.0140629 · Cited by 75 · see citing works
Liu, K., Wang, M., Huang, C., Yuan, Y., Ning, Y., Zhang, L., & Wan, P. (2023) · Advanced Science · doi:10.1002/advs.202305672 · Cited by 77 · see citing works
Ullah, A., Kim, D. Y., Lim, S. I., & Lim, H. (2025) · Gels · doi:10.3390/gels11040232 · Cited by 80 · see citing works
“These materials often trigger immune responses, leading to inflammation, fibrotic encapsulation, and performance degradation [178,179].”
Wang, G., Chen, Z., Jing, X., et al. (2024) · Carbohydrate Polymers · doi:10.1016/j.carbpol.2024.122048 · Cited by 71 · see citing works
Chen, S., Fan, S., Chan, H., Qiao, Z., Qi, J., Wu, Z., Yeo, J. C., & Lim, C. T. (2023) · Advanced Functional Materials · doi:10.1002/adfm.202309989 · Cited by 75 · see citing works
Materials and Structural Designs toward Motion Artifact-Free Bioelectronics
Park, B., Jeong, C., Ok, J., & Kim, T. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00374 · Cited by 78 · see citing works
Wang, Z., Wang, S., Du, Z., Yang, L., Cheng, X., & Wang, H. (2023) · Composites Part B Engineering · doi:10.1016/j.compositesb.2023.110999 · Cited by 69 · see citing works
Flexible and Stretchable Pressure Sensors: From Basic Principles to State-of-the-Art Applications
Seesaard, T., & Wongchoosuk, C. (2023) · Micromachines · doi:10.3390/mi14081638 · Cited by 70 · see citing works
Wang, S., Zhang, Z., Yang, B. T., Zhang, X., Shang, H., Jiang, L. W., Liu, H., Zhang, J., & Hu, P. (2022) · Chemical Engineering Journal · doi:10.1016/j.cej.2022.141136 · Cited by 71 · see citing works
Li, X., Rytkin, E., Zhao, Q., Bhat, P., Pfenniger, A., Yin, L., Huang, X., Yang, L., Yang, B., Burrell, A. R., et al. (2025) · Science Advances · doi:10.1126/sciadv.adw3044 · Cited by 78 · see citing works
Implantable hydrogels as pioneering materials for next-generation brain–computer interfaces
Khan, W. U., Shen, Z., Mugo, S. M., Wang, H., & Zhang, Q. M. (2025) · Chemical Society Reviews · doi:10.1039/d4cs01074d · Cited by 69 · see citing works
Bai, Y., Lu, Y., Bi, S., Wang, W., Lin, F., Zhu, F., Yang, P., Ding, N., Liu, S., Zhao, W., et al. (2023) · Advanced Materials Technologies · doi:10.1002/admt.202201767 · Cited by 69 · see citing works
Zhao, X., Xu, J., Zhang, J., et al. (2022) · Materials Horizons · doi:10.1039/d2mh01325h · Cited by 66 · see citing works
All Resistive Pressure–Temperature Bimodal Sensing E‐Skin for Object Classification
Han, S., Zhi, X., Xia, Y., Guo, W., Li, Q., Chen, D., Liu, K., & Wang, X. (2023) · Small · doi:10.1002/smll.202301593 · Cited by 65 · see citing works
Cui, Z., Wang, W., Xia, H., Wang, C., Tu, J., Ji, S., Tan, J. M. R., Liu, Z., Zhang, F., Li, W., et al. (2022) · Advanced Materials · doi:10.1002/adma.202207016 · Cited by 62 · see citing works
Emerging Wearable Acoustic Sensing Technologies
Liu, T., Mao, Y., Dou, H., Zhang, W., Yang, J., Wu, P., Li, D., & Mu, X. (2025) · Advanced Science · doi:10.1002/advs.202408653 · Cited by 70 · see citing works
Dai, J. J., Xie, G., Huo, X., Li, J., Deng, S., & Su, Y. (2025) · Small · doi:10.1002/smll.202407773 · Cited by 62 · see citing works
Recent progress in flexible piezoelectric devices toward human-machine interactions
Liu, J., Tian, G., Yang, W., et al. (2022) · Soft Science · doi:10.20517/ss.2022.23 · Cited by 60 · see citing works
Shi, W., Li, H., Chen, J., et al. (2024) · Advanced Science · doi:10.1002/advs.202404451 · Cited by 61 · see citing works
Mussel‐Inspired, Underwater Self‐Healing Ionoelastomers Based on α‐Lipoic Acid for Iontronics
Gao, J., Zhang, Q., Wu, B., Gao, X., Liu, Z., Yang, H., Yuan, J., & Huang, J. (2023) · Small · doi:10.1002/smll.202207334 · Cited by 69 · see citing works
Decoding tissue biomechanics using conformable electronic devices
Yoon, H., Kim, J., Sadat, D., Barrett, A., Ko, S. H., & Dağdeviren, C. (2024) · Nature Reviews Materials · doi:10.1038/s41578-024-00729-3 · Cited by 63 · see citing works
Fully Transient 3D Origami Paper-Based Ammonia Gas Sensor Obtained by Facile MXene Spray Coating
Wang, Z., Yan, F., Yu, Z., Cao, H., Ma, Z., YeErKenTai, Z., Li, Z., Han, Y., & Zhu, Z. (2024) · ACS Sensors · doi:10.1021/acssensors.3c02558 · Cited by 60 · see citing works
Peng, Y., Dong, J., Zhang, Y., Zhang, Y., Long, J., Sun, J., Liu, T. X., & Huang, Y. (2023) · Nano Energy · doi:10.1016/j.nanoen.2023.109143 · Cited by 59 · see citing works
Gou, X., Yang, J., Li, P., Su, M., Zhou, Z., Liao, C., Zhang, C., Dong, C., & Li, C. (2023) · Nano Energy · doi:10.1016/j.nanoen.2023.109140 · Cited by 59 · see citing works
Guo, J., Zhang, T., Hao, X., et al. (2025) · Nano-Micro Letters · doi:10.1007/s40820-025-01791-4 · Cited by 58 · see citing works
“…8], intelligent electronic skins [9–11], soft robots [12–14] and, etc. Traditional rigid electronics are being gradually replaced by flexible electronics due to the commensurate softness with human issues, conforming contact with substrate surface and long-term wearability of the latter [15–17].”
Zhang, Y., Zhang, W., Xia, J., et al. (2023) · Angewandte Chemie International Edition · doi:10.1002/anie.202314273 · Cited by 57 · see citing works
Emerging ultrasonic bioelectronics for personalized healthcare
Jiang, L., & Wu, J. (2023) · Progress in Materials Science · doi:10.1016/j.pmatsci.2023.101110 · Cited by 59 · see citing works
Wang, J., Li, X., Qian, H., et al. (2024) · Advanced Materials · doi:10.1002/adma.202310216 · Cited by 56 · see citing works
Wang, H., Liu, B., Chen, D., et al. (2024) · Materials Horizons · doi:10.1039/d4mh00174e · Cited by 55 · see citing works
Ling, W., Shang, X., Liu, J., & Tang, T. (2024) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2024.116852 · Cited by 56 · see citing works
Liu, W., Xiang, F., Mei, D., & Wang, Y. (2023) · Advanced Materials Technologies · doi:10.1002/admt.202301685 · Cited by 54 · see citing works
Mahato, M., Hwang, W., Tabassian, R., et al. (2022) · Advanced Materials · doi:10.1002/adma.202203613 · Cited by 53 · see citing works
Advances and perspectives in fiber-based electronic devices for next-generation soft systems
Kim, H.-J., Kim, D., Kim, J., Lee, Y., Shin, M., Kim, J., Bossuyt, F. M., Lee, G., Lee, B., Taylor, W. R., et al. (2025) · npj Flexible Electronics · doi:10.1038/s41528-025-00465-w · Cited by 56 · see citing works
“However, conventional rigid and bulky electronic devices reveal inherent limitations in speci fi c real-world environments that require mechanical fl exibility, stretchability, and adaptability to target surface 19,20 .”
Fully sprayed MXene-based high-performance flexible piezoresistive sensor for image recognition
Zhang, Z., Zhao, X., Zhang, Q.-C., Liang, J., Zhang, H., Zhang, T.-S., & Xue, C. (2023) · Nano Materials Science · doi:10.1016/j.nanoms.2023.06.001 · Cited by 50 · see citing works
Zhou, Y., Qu, Y., Yin, L., et al. (2022) · Composites Science and Technology · doi:10.1016/j.compscitech.2022.109415 · Cited by 51 · see citing works
Intelligent Biomaterialomics: Molecular Design, Manufacturing, and Biomedical Applications
Yi, Y., An, H., & Wang, H. (2023) · Advanced Materials · doi:10.1002/adma.202305099 · Cited by 52 · see citing works
The ultra-thin, minimally invasive surface electrode array NeuroWeb for probing neural activity
Lee, J. M., Pyo, Y., Kim, Y. J., Hong, J. H., Jo, Y., Choi, W., Lin, D., & Park, H. (2023) · Nature Communications · doi:10.1038/s41467-023-42860-9 · Cited by 53 · see citing works
Multifunctional Tactile Sensors for Object Recognition
Wang, L., Qi, X., Li, C., & Wang, Y. (2024) · Advanced Functional Materials · doi:10.1002/adfm.202409358 · Cited by 53 · see citing works
Wireless Battery-free and Fully Implantable Organ Interfaces
Bhatia, A., Hanna, J., Stuart, T., Kasper, K. A., Clausen, D. M., & Gutruf, P. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00425 · Cited by 50 · see citing works
Wang, Z., Jing, X., Duan, S., Liu, C., Kang, D., Xu, X. L., Chen, J., Xia, Y., Chang, B., Zhao, C., et al. (2023) · ACS Nano · doi:10.1021/acsnano.3c01582 · Cited by 50 · see citing works
Neuromorphic devices for electronic skin applications
Patil, C. S., Ghode, S. B., Kim, J., Kamble, G. U., Kundale, S. S., Mannan, A., Ko, Y., Noman, M. A., Saqib, Q. M., Patil, S. R., et al. (2025) · Materials Horizons · doi:10.1039/d4mh01848f · Cited by 48 · see citing works
Latest developments and trends in electronic skin devices
Zhu, P., Li, Z., Pang, J., He, P., & Zhang, S. (2024) · Soft Science · doi:10.20517/ss.2024.05 · Cited by 52 · see citing works
High wet-strength, durable composite film with nacre-like structure for moisture-driven actuators
Ma, H., Jiang, Y., Han, W., et al. (2023) · Chemical Engineering Journal · doi:10.1016/j.cej.2023.141353 · Cited by 48 · see citing works
Wu, S., Huang, J., Jing, S., Xie, H. Q., & Zhou, S. (2023) · Advanced Functional Materials · doi:10.1002/adfm.202303292 · Cited by 47 · see citing works
Organic Flexible Electronics for Innovative Applications in Electronic Skin
Liu, X., Li, H., Tao, M., Yu, Y., Zhu, Z., Wu, D., Hu, X., & Chen, Y. (2024) · Advanced Materials Technologies · doi:10.1002/admt.202400661 · Cited by 53 · see citing works
Shi, C., Liu, Z., Tian, Z., et al. (2022) · Applied Surface Science · doi:10.1016/j.apsusc.2022.153632 · Cited by 47 · see citing works
Khan, M., Shah, L. A., Fu, J., et al. (2024) · Chemical Engineering Journal · doi:10.1016/j.cej.2024.159008 · Cited by 47 · see citing works
Wang, Q., Zhang, J., Yu, J., Lang, J., Lyu, Z., Chen, Y., & Zhang, L. (2023) · ACS Nano · doi:10.1021/acsnano.3c05328 · Cited by 48 · see citing works
Mechanoluminescent optical fiber sensors for human–computer interaction
Ren, B., Chen, B., Zhang, X., Wu, H., Fu, Y., & Peng, D. (2023) · 中国科学通报:英文版 · doi:10.1016/j.scib.2023.02.030 · Cited by 46 · see citing works
Zeng, M., Ding, J., Tian, Y., et al. (2025) · Advanced Materials · doi:10.1002/adma.202505635 · Cited by 43 · see citing works
Exhaled Breath Analysis: From Laboratory Test to Wearable Sensing
Heng, W., Yin, S., Chen, Y., & Gao, W. (2024) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2024.3481360 · Cited by 45 · see citing works
“Traditional HMI methods typically depend on mechanical, acoustic, bio-electrical, or optical inputs [348], [349].”
Self-citationWang, P. P., Lan, Y., Huan, C., Luo, J., Cai, W., Fan, J., He, X., Huang, Z., Zhu, H. L., Ke, Q., et al. (2023) · Materials Science and Engineering R Reports · doi:10.1016/j.mser.2023.100759 · Cited by 44 · see citing works
- Authors
- Heng, W., Solomon, S., & Gao, W.
- Affiliations
- California Institute of Technology (US)
- Corresponding author
- Gao, Wei
- Venue
- Advanced Materials
- Publisher
- Wiley
- Published
- 2022-02-25
- Volume
- 34
- Issue
- 16
- Pages
- e2107902-e2107902
- ISSN
- 0935-9648 (ISSN-L)
- 1521-4095
- PMC
- PMC9035141
- OpenAlex
- W4200567725
- Cited by
- 609
- References
- 615
- Citations by year
- 2026: 113 · 2025: 156 · 2024: 165 · 2023: 133 · 2022: 42
- FWCI
- 7.19
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- Locations
- Advanced Materials (publishedVersion, cc-by-nc)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- eScholarship (California Digital Library) (submittedVersion, cc-by-nc)
- CaltechAUTHORS (California Institute of Technology) (submittedVersion)
- Funders
- National Institutes of Health (R01HL155815)
- Office of Naval Research (N00014‐21‐1‐2483, N00014‐21‐1‐2845)
- National Aeronautics and Space Administration (NNX16AO69A)
- California Institute of Technology
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Soft Robotics and Applications
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Keywords
- flexible electronics, human-machine interaction, medical robotics, soft robotics, prosthetics, rehabilitation devices, biomaterials, physiological sensing, physiological recording
- MeSH terms
- Electronics, Humans, Quality of Life, Robotics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Claims read under definition version 3 (extract-v3) on 2026-09-28.
Classified by jev-1.13-20260917 (gold-guideline-v0.2) on 2026-09-28.
Cited sources are checked by gpt-6-sol.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review