Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 304

The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.

Sensitive and Stable 2D Perovskite Single‐Crystal X‐ray Detectors Enabled by a Supramolecular Anchor

Li, Huayang, Song, Jinmei, Pan, Wanting, Xu, Daren, Zhu, Wan‐an, Wei, Haotong, Yang, Bai·2020·Advanced Materials

Abstract

Perovskite X‐ray detectors have been demonstrated to be sensitive to soft X‐rays (<80 keV) for potential medical imaging applications. However, developing X‐ray detectors that are stable and sensitive to hard X‐rays (80 to 120 keV) for practical medical imaging is highly desired. Here, a sensitive 2D fluorophenethylammonium lead iodide ((F‐PEA)2 PbI 4) perovskite single‐crystal hard‐X‐ray detector from low‐cost solution processes is reported. Dipole interaction of organic ions promotes the ordering of benzene rings as well as the supramolecular electrostatic interaction between electron‐deficient F atoms with neighbor benzene rings. Supramolecular interactions serve as a supramolecular anchor to stabilize and tune the electronic properties of single crystals. The 2D (F‐PEA)2 PbI 4 perovskite single crystal exhibits an intrinsic property with record bulk resistivity of 1.36 × 10 12 Ω cm, which brings a low device noise for hard X‐ray detection. Meanwhile, the ion‐migration phenomenon is effectively suppressed, even under the large applied bias of 200 V, by blocking the ion migration paths after anchoring. Consequently, the (F‐PEA)2 PbI 4 single crystal detector yields a sensitivity of 3402 μC Gy−1 air cm−2 to 120 keV p hard X‐rays with lowest detectable X‐ray dose rate of 23 nGy air s−1, outperforming the dominating CsI scintillator of commercial digital radiography systems by acquiring clear X‐ray images under much lower dose rate. In addition, the detector shows high operation stability under extremely high‐flux X‐ray irradiation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/adma.202003790

Cites

30 of 30 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 30 references

Cited by

See all 304

Metadata

Authors
Li, H., Song, J., Pan, W., Xu, D., Zhu, W., Wei, H., & Yang, B.
Venue
Advanced Materials
Publisher
Wiley
Published
2020-09-02
Volume
32
Issue
40
Pages
e2003790-e2003790
ISSN
  • 0935-9648 (ISSN-L)
  • 1521-4095
OpenAlex
W3081687341
Cited by
304
References
30
FWCI
25.18
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Sensitive and Stable 2D Perovskite Single‐Crystal X‐ray Detectors Enabled by a Supramolecular Anchor. https://app.cochat.ai/papers/10.1002/adma.202003790
The paper
Li, H., Song, J., Pan, W., Xu, D., Zhu, W., Wei, H., & Yang, B. (2020). Sensitive and Stable 2D Perovskite Single‐Crystal X‐ray Detectors Enabled by a Supramolecular Anchor. Advanced Materials. https://doi.org/10.1002/adma.202003790

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.