Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 250

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Reversibly Transforming a Highly Swollen Polyelectrolyte Hydrogel to an Extremely Tough One and its Application as a Tubular Grasper

Yu, Hai Chao, Zheng, Si Yu, Fang, Lingtao, Ying, Zhimin, Du, Miao, Wang, Jing, Ren, Ke‐Feng, Wu, Zi Liang, Zheng, Qiang·2020·Advanced Materials

Abstract

Poly(2‐acrylamido‐2‐methyl‐1‐propanesulfonic acid) and its copolymer hydrogels are typical polyelectrolyte gels with extremely high swelling capacity that are widely used in industry. It's common to consider these hydrogels as weak materials that are difficult to toughen. Reported here is a facile strategy to transform swollen and weak poly(acrylamide‐co‐2‐acrylamido‐2‐methyl‐1‐propanesulfonic acid) [P(AAm‐co‐AMPS)] hydrogels to tough ones by forming strong sulfonate–Zr 4+ metal‐coordination complexes. The resultant hydrogels with moderate water content possess high stiffness, strength, and fracture energy, which can be tuned over 3–4 orders of magnitude by controlling the composition and metal‐to‐ligand ratio. Owing to the dynamic nature of the coordination bonds, these hydrogels show rate‐ and temperature‐dependent mechanical performances, as well as good self‐recovery properties. This strategy is universal, as manifested by the drastically improved mechanical properties of hydrogels of various natural and synthetic sulfonate‐containing polymers. The toughened hydrogels can be converted to the original swollen ones by breaking up the metal‐coordination complexes in alkaline solutions. The reversible brittle–tough transition and concomitant dramatic volume change of polyelectrolyte hydrogels afford diverse applications, as demonstrated by the design of a tubular grasper with holding force a thousand times its own weight for objects with different geometries. It is envisioned that these hydrogels enable versatile applications in the biomedical and engineering fields.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/adma.202005171

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 250

Metadata

Authors
Yu, H. C., Zheng, S. Y., Fang, L., Ying, Z., Du, M., Wang, J., Ren, K., Wu, Z. L., & Zheng, Q.
Venue
Advanced Materials
Publisher
Wiley
Published
2020-11-05
Volume
32
Issue
49
Pages
e2005171-e2005171
ISSN
  • 0935-9648 (ISSN-L)
  • 1521-4095
OpenAlex
W3094923955
Cited by
250
References
5
FWCI
9.43
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Reversibly Transforming a Highly Swollen Polyelectrolyte Hydrogel to an Extremely Tough One and its Application as a Tubular Grasper. https://app.cochat.ai/papers/10.1002/adma.202005171
The paper
Yu, H. C., Zheng, S. Y., Fang, L., Ying, Z., Du, M., Wang, J., Ren, K., Wu, Z. L., & Zheng, Q. (2020). Reversibly Transforming a Highly Swollen Polyelectrolyte Hydrogel to an Extremely Tough One and its Application as a Tubular Grasper. Advanced Materials. https://doi.org/10.1002/adma.202005171

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.