The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Supersaturation‐Controlled Growth of Monolithically Integrated Lead‐Free Halide Perovskite Single‐Crystalline Thin Film for High‐Sensitivity Photodetectors
Abstract
Monolithical integration of the promising optoelectronic material with mature and inexpensive silicon circuitry contributes to simplifying device geometry, enhancing performance, and expanding new functionalities. Herein, a lead‐free halide perovskite Cs 3 Bi 2 I 9 single‐crystalline thin film (SCTF), with thickness ranging from 900 nm to 4.1 µm and aspect ratio up to 1666, is directly integrated on various substrates including Si wafer, through a facile and low‐temperature solution‐processing method. The growth kinetics of the lead‐free halide perovskite SCTF are elucidated by in situ observation, and the solution supersaturation is controlled to reduce the inverse‐temperature crystallization nucleation density and elongate the evaporation growth. The excellent lattice match and band alignment between Si(111) and Cs 3 Bi 2 I 9(001) facets promote photogenerated charge dissociation and extraction, resulting in boosting the photoelectric sensitivity by 10–200 times compared with photodetectors based on other substrates. More importantly, this silicon‐compatible perovskite SCTF photodetector exhibits a high switching ratio of 3000 and a fast response of 1.5 µs, which are higher than most reported state‐of‐the‐art lead‐free halide perovskite photodetectors. This work not only gives an in‐depth understanding of the perovskite precursor solution chemistry, but also demonstrates the great potential of monolithical integration of lead‐free halide perovskite SCTF with a silicon wafer for high‐performance photodetectors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ultrafast Photodetector by Integrating Perovskite Directly on Silicon Wafer
Geng, X., Wang, F., Tian, H., Feng, Q., Zhang, H., Liang, R., Shen, Y., Ju, Z., Gou, G.-Y., Deng, N., et al. (2020) · ACS Nano · doi:10.1021/acsnano.9b06345 · Cited by 136
Cited by
Low-dimensional wide-bandgap semiconductors for UV photodetectors
Li, Z., Yan, T., & Fang, X. (2023) · Nature Reviews Materials · doi:10.1038/s41578-023-00583-9 · Cited by 692
Self-citationApplication of Nanostructured TiO2 in UV Photodetectors: A Review
Li, Z., Li, Z., Zuo, C., & Fang, X. (2022) · Advanced Materials · doi:10.1002/adma.202109083 · Cited by 371
Self-citationWu, J., Zhang, X., Wang, Z., Liang, L., Niu, X., Guan, Q., You, S., & Luo, J. (2023) · Materials Horizons · doi:10.1039/d2mh01287a · Cited by 26
Metadata
- Authors
- Li, Z., Liu, X., Zuo, C., Yang, W., & Fang, X.
- Venue
- Advanced Materials
- Publisher
- Wiley
- Published
- 2021-08-25
- Volume
- 33
- Issue
- 41
- Pages
- e2103010-e2103010
- ISSN
- 0935-9648 (ISSN-L)
- 1521-4095
- OpenAlex
- W3195967278
- Cited by
- 212
- References
- 1
- FWCI
- 11.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Supersaturation‐Controlled Growth of Monolithically Integrated Lead‐Free Halide Perovskite Single‐Crystalline Thin Film for High‐Sensitivity Photodetectors. https://app.cochat.ai/papers/10.1002/adma.202103010
- The paper
- Li, Z., Liu, X., Zuo, C., Yang, W., & Fang, X. (2021). Supersaturation‐Controlled Growth of Monolithically Integrated Lead‐Free Halide Perovskite Single‐Crystalline Thin Film for High‐Sensitivity Photodetectors. Advanced Materials. https://doi.org/10.1002/adma.202103010
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.