Bio‐Inspired, Miniaturized Magnetic Heart Valve System for Superior Performance Cardiovascular Simulator
Open accessAbstract
The demand for accurate vascular simulators is increasing to facilitate effective clinical studies on cardiovascular diseases. The research presents the miniaturized design and precise programable regulation of an artificial magnetic heart valve inspired by the human aortic valve, demonstrating the diverse types of pulsating waves. The heart valve is constructed using an elastomeric silicone composite embedded with neodymium magnetic micro-particles. This valve system responds rapidly to changes in magnetic fields controlled by miniaturized electromagnets, enabling precise regulation of fluid pressure and flow rate. This allows for the generation of various pressure waveforms and accurately replicates diverse blood pressure changes with a compact design. The design, working mechanism, fabrication process, and optimization of the magnetically controlled biomimetic heart valve are discussed and its performance as a cardiovascular simulator for human and animal models is evaluated. This artificial valve system has the potential to be utilized in humanoid robots to generate heart-like pressure, thereby paving the way for replicating human physiological characteristics. This research promises significant advancements in cardiovascular clinical trials and biomedical research along with the development of humanoid robots and biomimetic mechanical systems.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Magnetic valve systems with a 0.5 T field optimize energy efficiency in simulations.
“while magnetic valve systems with a 0.5 T field optimize energy efficiency in simulations [15].”
From Hybrid Fault-Tolerant Control in Cooperative Robotics: Advances in Resilience and Scalability (2025) · cites this paper as [15]
Cited by
Sorted by citations
Hybrid Fault-Tolerant Control in Cooperative Robotics: Advances in Resilience and Scalability
Urrea, C. (2025) · Actuators · doi:10.3390/act14040177 · Cited by 19 · see citing works
“Recent advancements, detailed in Section Key Technical Methods in Hybrid FTC, integrate optimization techniques to refine control precision, while magnetic valve systems with a 0.5 T field extend responsiveness to medical simulations [15].”
Influential
- Authors
- Yoo, J., Chung, G., & Park, Y.
- Affiliations
- Kyung Hee University (KR)
- Corresponding author
- Park, Yoonseok
- Venue
- Advanced Materials
- Publisher
- Wiley
- Published
- 2025-02-16
- Volume
- 37
- Issue
- 16
- Pages
- e2419504-e2419504
- ISSN
- 0935-9648 (ISSN-L)
- 1521-4095
- OpenAlex
- W4407610895
- Cited by
- 13
- References
- 0
- Citations by year
- 2026: 7 · 2025: 6
- FWCI
- 3.16
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- Locations
- Advanced Materials (publishedVersion, cc-by-nc-nd)
- PubMed (publishedVersion)
- Funders
- National Research Foundation of Korea
- Korea Institute of Science and Technology (2E33561)
- Kyung Hee University (GS‐1‐JO‐NON‐20240369)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Soft Robotics and Applications
- Physical Sciences › Engineering › Biomedical Engineering › Mechanical Circulatory Support Devices
- Physical Sciences › Engineering › Mechanical Engineering › Advanced Materials and Mechanics
- Keywords
- cardiovascular simulator, aortic valve, silicone elastomer composites, electromagnet control, humanoid robots
- MeSH terms
- Animals, Heart Valve Prosthesis, Humans, Miniaturization, Biomimetics, Biomimetic Materials
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review