Preparation and properties of heat‐shrinkable cross‐linked low‐density polyethylene
Abstract
Abstract In this work, heat‐shrinkable characteristics of a polyethylene compound were obtained by blending mixtures of low‐density polyethylene with varying amount of peroxide. These were then extruded and molded to the required shape and then cross‐linked by chemical means, followed by heating and stretching and then cooled to “freeze‐in” the oriented polymer structure (elastic memory). A decrease in the melting point and heat of fusion (ΔHf), as determined from the DSC melting enthalpies, was observed with an increase in the dicumyl peroxide (DCP) concentration. Tests on the heat shrinkablity of the samples showed that the stretching temperature has a large effect on the shrinkage temperature. The results showed that by increasing the peroxide content, the shrinkage temperature was decreased. The elongation at break decreased with an increase in the DCP concentration. Increasing the temperature in lightly cross‐linked samples (low percent DCP) resulted in a reduction in the elongation at break. Increasing the cross‐linking density (DCP content) gave an opposite effect. © 2003 Wiley Periodicals, Inc. Adv Polym Techn 22: 112–119, 2003; Published online in Wiley InterScience (www.interscience.wiley.com). DOI 10.1002/adv.10041
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the food packaging sector SMPs can be used for heat-shrinkable packaging films, for instance for thermally processed food.
“Particularly, in the food packaging sector SMPs can be used for heat-shrinkable packaging films, for instance for thermally processed food [18, 19].”
From Biodegradable poly(ester-urethane) incorporated with catechin with shape memory and antioxidant activity for food packaging (2017) · cites this paper as [18]
Cited by
Sorted by citations
Shape-memory polymers and their composites: stimulus methods and applications
Leng, J., Lan, X., Liu, Y., & Du, S. (2011) · Progress in Materials Science · doi:10.1016/j.pmatsci.2011.03.001 · Cited by 1,495 · see citing works
Shape and temperature memory of nanocomposites with broadened glass transition
Miaudet, P., Derré, A., Maugey, M., Zakri, C., Piccione, P. M., Inoubli, R., & Poulin, P. (2007) · Science · doi:10.1126/science.1145593 · Cited by 416 · see citing works
Nanotube fibers for electromechanical and shape memory actuators
Viry, L., Mercader, C., Miaudet, P., Zakri, C., Derré, A., Kuhn, A., Maugey, M., & Poulin, P. (2010) · Journal of Materials Chemistry · doi:10.1039/b924430a · Cited by 70 · see citing works
Arrieta, M. P., Sessini, V., & Peponi, L. (2017) · European Polymer Journal · doi:10.1016/j.eurpolymj.2017.06.047 · Cited by 55 · see citing works
- Authors
- Morshedian, J., Khonakdar, H. A., Mehrabzadeh, M., & Eslami, H.
- Affiliations
- Iran Polymer and Petrochemical Institute (IR)
- Corresponding author
- Khonakdar, H. A.
- ORCID
- Khonakdar, H. A.
- Venue
- Advances in Polymer Technology
- Publisher
- Wiley
- Published
- 2003-03-25
- Volume
- 22
- Issue
- 2
- Pages
- 112-119
- ISSN
- 0730-6679 (ISSN-L)
- 1098-2329
- OpenAlex
- W2038629595
- Cited by
- 71
- References
- 0
- Citations by year
- 2026: 1 · 2025: 4 · 2024: 5 · 2023: 2 · 2022: 4 · 2021: 4 · 2019: 6 · 2018: 3 · 2017: 2 · 2016: 5 · 2015: 1 · 2014: 5 · 2013: 4 · 2012: 3
- FWCI
- 2.60
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Advances in Polymer Technology (publishedVersion)
- Topics
- Physical Sciences › Materials Science › Polymers and Plastics › Polymer crystallization and properties
- Physical Sciences › Materials Science › Polymers and Plastics › Polymer Foaming and Composites
- Physical Sciences › Materials Science › Polymers and Plastics › Polymer composites and self-healing
- Keywords
- low-density polyethylene, cross-linked polyethylene, dicumyl peroxide, peroxide crosslinking, shrinkage temperature, melting point depression, heat of fusion, elongation at break, crosslink density
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review