3D Fabrication with Integration Molding of a Graphene Oxide/Polycaprolactone Nanoscaffold for Neurite Regeneration and Angiogenesis
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Treating peripheral nerve injury faces major challenges and may benefit from bioactive scaffolds due to the limited autograft resources. Graphene oxide (GO) has emerged as a promising nanomaterial with excellent physical and chemical properties. GO has functional groups that confer biocompatibility that is better than that of graphene. Here, GO/polycaprolactone (PCL) nanoscaffolds are fabricated using an integration molding method. The nanoscaffolds exhibit many merits, including even GO nanoparticle distribution, macroporous structure, and strong mechanical support. Additionally, the process enables excellent quality control. In vitro studies confirm the advantages of the GO/PCL nanoscaffolds in terms of Schwann cell proliferation, viability, and attachment, as well as neural characteristics maintenance. This is the first study to evaluate the in vivo performance of GO‐based nanoscaffolds in this context. GO release and PCL biodegradation is analyzed after long‐term in vivo study. It is also found that the GO/PCL nerve guidance conduit could successfully repair a 15 mm sciatic nerve defect. The pro‐angiogenic characteristic of GO is evaluated in vivo using immunohistochemistry. In addition, the AKT‐endothelial nitric oxide synthase (eNOS)‐vascular endothelial growth factor (VEGF) signaling pathway might play a major role in the angiogenic process. These findings demonstrate that the GO/PCL nanoscaffold efficiently promotes functional and morphological recovery in peripheral nerve regeneration, indicating its promise for tissue engineering applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Regenerated sciatic nerve axons stimulated through a chronically implanted macro-sieve electrode
MacEwan, M. R., Zellmer, E. R., Wheeler, J. J., Burton, H., & Moran, D. W. (2016) · Frontiers in Neuroscience · doi:10.3389/fnins.2016.00557 · Cited by 48
Cited by
Nanocomposite scaffolds for accelerating chronic wound healing by enhancing angiogenesis
Nosrati, H., Aramideh Khouy, R., Nosrati, A., Khodaei, M., Banitalebi-Dehkordi, M., Ashrafi-Dehkordi, K., Sanami, S., & Alizadeh, Z. (2021) · Journal of Nanobiotechnology · doi:10.1186/s12951-020-00755-7 · Cited by 720
Wang, J., Cheng, Y., Chen, L., Zhu, T., Ye, K., Jia, C., Wang, H., Zhu, M., Fan, C., & Mo, X. (2019) · Acta Biomaterialia · doi:10.1016/j.actbio.2018.11.032 · Cited by 232
Self-citationHsu, R., Chen, P., Fang, J., Chen, Y., Chang, C., Lu, Y., & Hu, S. (2019) · Advanced Science · doi:10.1002/advs.201900520 · Cited by 178
Ma, Y., Wang, H., Wang, Q., Cao, X., & Gao, H. (2023) · Chemical Engineering Journal · doi:10.1016/j.cej.2022.139424 · Cited by 103
Zhou, W., Rahman, M. S. U., Sun, C., Li, S., Zhang, N., Chen, H., Han, C. C., Xu, S., & Liu, Y. (2024) · Advanced Materials · doi:10.1002/adma.202307805 · Cited by 65
Metadata
- Authors
- Qian, Y., Song, J., Zhao, X., Chen, W., Ouyang, Y., Yuan, W., & Fan, C.
- Venue
- Advanced Science
- Publisher
- Wiley
- Published
- 2018-01-26
- Volume
- 5
- Issue
- 4
- Pages
- 1700499-1700499
- ISSN
- 2198-3844 (ISSN-L)
- OpenAlex
- W2793302862
- Cited by
- 198
- References
- 1
- FWCI
- 8.49
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: 3D Fabrication with Integration Molding of a Graphene Oxide/Polycaprolactone Nanoscaffold for Neurite Regeneration and Angiogenesis. https://app.cochat.ai/papers/10.1002/advs.201700499
- The paper
- Qian, Y., Song, J., Zhao, X., Chen, W., Ouyang, Y., Yuan, W., & Fan, C. (2018). 3D Fabrication with Integration Molding of a Graphene Oxide/Polycaprolactone Nanoscaffold for Neurite Regeneration and Angiogenesis. Advanced Science. https://doi.org/10.1002/advs.201700499
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.