The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Rapid Response Fluorescence Probe Enabled In Vivo Diagnosis and Assessing Treatment Response of Hypochlorous Acid‐Mediated Rheumatoid Arthritis
Open accessAbstract
Diagnosis and early assessment of the treatment response of rheumatoid arthritis (RA) necessitates a reliable bioanalytical method for rapid, sensitive, and specific detection of the hypochlorous acid (HOCl) biomarker in inflammatory diseases. Herein, two fluorescence probes, Probe‐1 and Probe‐2 are developed for quantitative monitoring and visualization of inflammatory response–related HOCl levels in vitro and in vivo. In the presence of HOCl, fluorescence “OFF–ON” response is obtained for both the probes as a result of specific HOCl‐triggered CN bond cleavage reaction. Probe‐1 and Probe‐2 feature rapid response (<4 s), a high degree of sensitivity and selectivity toward HOCl, which allow them to be used for quantification of HOCl in a simulated physiological condition. Using Probe‐2 as the probe, fluorescence imaging and flow cytometry analysis of HOCl levels in lysosome of inflammatory mimic cells, visualization of HOCl generation in endotoxin‐induced inflammation of adult zebrafish and RA of mice are possible. Probe‐2 exhibits high effectiveness for early assessment of the treatment response of HOCl‐mediated RA in mice with an antiarthritic drug, methotrexate (MTX). The results demonstrate that Probe‐2 is a powerful tool for future studies on diagnosis and monitoring treatment efficiency in a broad range of inflammatory diseases, including RA.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fluorescent and luminescent probes for detection of reactive oxygen and nitrogen species
Chen, X., Tian, X., Shin, I., & Yoon, J. (2011) · Chemical Society Reviews · doi:10.1039/c1cs15037e · Cited by 980
Cited by
Fluorescent Probes for Disease Diagnosis
Wang, X., Ding, Q., Groleau, R. R., Wu, L., Mao, Y., Che, F., Kotova, O., Scanlan, E. M., Lewis, S. E., Li, P., et al. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00776 · Cited by 543
Niu, H., Liu, J., O’Connor, H. M., Gunnlaugsson, T., James, T. D., & Zhang, H. (2023) · Chemical Society Reviews · doi:10.1039/d1cs01097b · Cited by 449
A Redox-Switchable Colorimetric Probe for “Naked-Eye” Detection of Hypochlorous Acid and Glutathione
Han, Q., Zhou, F., Wang, Y., Feng, H., Meng, Q., Zhang, Z., & Zhang, R. (2019) · Molecules · doi:10.3390/molecules24132455 · Cited by 23
Self-citation
Metadata
- Authors
- Feng, H., Zhang, Z., Meng, Q., Jia, H., Wang, Y., & Zhang, R.
- Venue
- Advanced Science
- Publisher
- Wiley
- Published
- 2018-06-07
- Volume
- 5
- Issue
- 8
- Pages
- 1800397-1800397
- ISSN
- 2198-3844 (ISSN-L)
- OpenAlex
- W2805751293
- Cited by
- 168
- References
- 1
- FWCI
- 6.89
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Rapid Response Fluorescence Probe Enabled In Vivo Diagnosis and Assessing Treatment Response of Hypochlorous Acid‐Mediated Rheumatoid Arthritis. https://app.cochat.ai/papers/10.1002/advs.201800397
- The paper
- Feng, H., Zhang, Z., Meng, Q., Jia, H., Wang, Y., & Zhang, R. (2018). Rapid Response Fluorescence Probe Enabled In Vivo Diagnosis and Assessing Treatment Response of Hypochlorous Acid‐Mediated Rheumatoid Arthritis. Advanced Science. https://doi.org/10.1002/advs.201800397
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.