The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Self‐Sustainable Wearable Textile Nano‐Energy Nano‐System (NENS) for Next‐Generation Healthcare Applications
Open accessAbstract
Wearable electronics presage a future in which healthcare monitoring and rehabilitation are enabled beyond the limitation of hospitals, and self‐powered sensors and energy generators are key prerequisites for a self‐sustainable wearable system. A triboelectric nanogenerator (TENG) based on textiles can be an optimal option for scavenging low‐frequency and irregular waste energy from body motions as a power source for self‐sustainable systems. However, the low output of most textile‐based TENGs (T‐TENGs) has hindered its way toward practical applications. In this work, a facile and universal strategy to enhance the triboelectric output is proposed by integration of a narrow‐gap TENG textile with a high‐voltage diode and a textile‐based switch. The closed‐loop current of the diode‐enhanced textile‐based TENG (D‐T‐TENG) can be increased by 25 times. The soft, flexible, and thin characteristics of the D‐T‐TENG enable a moderate output even as it is randomly scrunched. Furthermore, the enhanced current can directly stimulate rat muscle and nerve. In addition, the capability of the D‐T‐TENG as a practical power source for wearable sensors is demonstrated by powering Bluetooth sensors embedded to clothes for humidity and temperature sensing. Looking forward, the D‐T‐TENG renders an effective approach toward a self‐sustainable wearable textile nano‐energy nano‐system for next‐generation healthcare applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Trung, T. Q., Ramasundaram, S., Hwang, B., & Lee, N. (2016) · Advanced Materials · doi:10.1002/adma.201504441 · Cited by 870
Biodegradable triboelectric nanogenerator as a life-time designed implantable power source
Zheng, Q., Zou, Y., Zhang, Y., Liu, Z., Shi, B., Wang, X., Jin, Y., Ouyang, H., Li, Z., & Wang, Z. L. (2016) · Science Advances · doi:10.1126/sciadv.1501478 · Cited by 617
Fully Bioabsorbable Natural‐Materials‐Based Triboelectric Nanogenerators
Jiang, W., Li, H., Liu, Z., Li, Z., Tian, J., Shi, B., Zou, Y., Ouyang, H., Zhao, C., Zhao, L., et al. (2018) · Advanced Materials · doi:10.1002/adma.201801895 · Cited by 449
Reeder, J. T., Choi, J., Xue, Y., Gutruf, P., Hanson, J., Liu, M., Ray, T., Bandodkar, A. J., Avila, R., Xia, W., et al. (2019) · Science Advances · doi:10.1126/sciadv.aau6356 · Cited by 308
Cited by
Electronic Textiles for Wearable Point-of-Care Systems
Chen, G., Xiao, X., Zhao, X., Tat, T., Bick, M., & Chen, J. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00502 · Cited by 688
Wen, F., Zhang, Z., He, T., & Lee, C. (2021) · Nature Communications · doi:10.1038/s41467-021-25637-w · Cited by 494
Self-citationWen, F., Sun, Z., He, T., Shi, Q., Zhu, M., Zhang, Z., Li, L., Zhang, T., & Lee, C. (2020) · Advanced Science · doi:10.1002/advs.202000261 · Cited by 478
Self-citationZhang, Q., Jin, T., Cai, J., Xu, L., He, T., Wang, T., Tian, Y., Li, L., Peng, Y., & Lee, C. (2022) · Advanced Science · doi:10.1002/advs.202103694 · Cited by 386
Self-citationHe, W., Liu, W., Chen, J., Wang, Z., Liu, Y., Pu, X., Yang, H., Tang, Q., Yang, H., Guo, H., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-18086-4 · Cited by 303
Metadata
- Authors
- He, T., Wang, H., Wang, J., Tian, X., Wen, F., Shi, Q., Ho, J. S., & Lee, C.
- Venue
- Advanced Science
- Publisher
- Wiley
- Published
- 2019-10-24
- Volume
- 6
- Issue
- 24
- Pages
- 1901437-1901437
- ISSN
- 2198-3844 (ISSN-L)
- OpenAlex
- W2982072179
- Cited by
- 252
- References
- 4
- FWCI
- 10.53
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.