Fully Bioabsorbable Natural‐Materials‐Based Triboelectric Nanogenerators
Abstract
Implantable medical devices provide an effective therapeutic approach for neurological and cardiovascular diseases. With the development of transient electronics, a new power source with biocompatibility, controllability, and bioabsorbability becomes an urgent demand for medical sciences. Here, various fully bioabsorbable natural‐materials‐based triboelectric nanogenerators (BN‐TENGs), in vivo, are developed. The “triboelectric series” of five natural materials is first ranked, it provides a basic knowledge for materials selection and device design of the TENGs and other energy harvesters. Various triboelectric outputs of these natural materials are achieved by a single material and their pairwise combinations. The maximum voltage, current, and power density reach up to 55 V, 0.6 µA, and 21.6 mW m−2, respectively. The modification of silk fibroin encapsulation film makes the operation time of the BN‐TENG tunable from days to weeks. After completing its function, the BN‐TENG can be fully degraded and resorbed in Sprague–Dawley rats, which avoids a second operation and other side effects. Using the proposed BN‐TENG as a voltage source, the beating rates of dysfunctional cardiomyocyte clusters are accelerated and the consistency of cell contraction is improved. This provides a new and valid solution to treat some heart diseases such as bradycardia and arrhythmia.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Research on implantable devices makes high requirements for materials selection, structure design, system integration, power supply, and biological safety.
“Meanwhile, the research on implantable devices also makes high requirements for materials selection, structure design, system integration, power supply, and biological safety (Jiang et al. 2018; Wang et al. 2019; Yao et al. 2022; Zhao et al. 2019).”
From Artificial intelligence enhanced sensors - enabling technologies to next-generation healthcare and biomedical platform (2023) · cites this paper as Jiang et al. 2018
When egg white and rice paper are adopted as triboelectric materials, the fabricated TENG can produce a maximum voltage, current, and power density of 55 V, 0.6 μA, and 21.6 mW/m2, respectively.
“When egg white (EW) and rice paper (RP) are adopted as triboelectric materials, the fabricated TENG can produce a maximum voltage, current, and power density of 55 V, 0.6 µA, and 21.6 mW/m 2 , respectively.”
From From flexible electronics technology in the era of IoT and artificial intelligence toward future implanted body sensor networks (2019) · cites this paper as [115]
Various natural materials with complete bioabsorbability are investigated as triboelectric materials for biodegradable TENGs.
“As depicted in Fig. 5(c), various natural materials with complete bioabsorbability are investigated as the triboelectric materials for biodegradable TENGs.115”
From From flexible electronics technology in the era of IoT and artificial intelligence toward future implanted body sensor networks (2019) · cites this paper as [115]
The positions of five natural materials in the triboelectric series are measured and ranked, providing guidance for material selection of biodegradable TENGs.
“The positions of the five natural materials in “triboelectric series” are measured and ranked, providing guidance for material selection of biodegradable TENGs.”
From From flexible electronics technology in the era of IoT and artificial intelligence toward future implanted body sensor networks (2019) · cites this paper as [115]
After modification of the silk fibroin encapsulation film, the operation lifetime can be tuned from days to weeks.
“After modification of the silk fibroin encapsulation film, the operation lifetime can be tuned from days to weeks.”
From From flexible electronics technology in the era of IoT and artificial intelligence toward future implanted body sensor networks (2019) · cites this paper as [115]
The citation lists haven’t been fetched yet
References 52 · Cited by 449
- Authors
- Jiang, W., Li, H., Liu, Z., Li, Z., Tian, J., Shi, B., Zou, Y., Ouyang, H., Zhao, C., Zhao, L., Sun, R., Zheng, H., Fan, Y., Wang, Z. L., & Li, Z.
- Affiliations
- Chinese Academy of Sciences (CN)
- Beihang University (CN)
- Georgia Institute of Technology (US)
- Corresponding author
- Fan, Yubo
- Wang, Zhong Lin
- Li, Zhou
- ORCID
- Venue
- Advanced Materials
- Publisher
- Wiley
- Published
- 2018-06-26
- Volume
- 30
- Issue
- 32
- Pages
- e1801895-e1801895
- ISSN
- 0935-9648 (ISSN-L)
- 1521-4095
- OpenAlex
- W2811024345
- Cited by
- 449
- References
- 52
- Citations by year
- 2026: 23 · 2025: 49 · 2024: 60 · 2023: 71 · 2022: 64 · 2021: 55 · 2020: 62 · 2019: 53 · 2018: 12
- FWCI
- 18.19
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Advanced Materials (publishedVersion)
- PubMed (publishedVersion)
- Minerva Access (University of Melbourne) (submittedVersion)
- Funders
- National Natural Science Foundation of China (31571006, 81601629, 61501039)
- Natural Science Foundation of Beijing Municipality (2182091, 2162017)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Physical Sciences › Materials Science › Biomaterials › Electrospun Nanofibers in Biomedical Applications
- Physical Sciences › Environmental Science › Environmental Engineering › Microbial Fuel Cells and Bioremediation
- Keywords
- triboelectric nanogenerator, bioresorbable materials, natural materials, silk fibroin, implantable power sources, transient electronics, energy harvesting, biodegradation, cardiomyocyte beating, antiarrhythmic therapy, biocompatibility
- MeSH terms
- Animals, Equipment Design, Electric Power Supplies, Rats, Sprague-Dawley, Absorbable Implants, Nanotechnology, Nanostructures, Rats
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review