The DOI matches its Crossref record; 80 of the 80 references it cites were found in a registry or an index.
Is it Time for Reviewer 3 to Request Human Organ Chip Experiments Instead of Animal Validation Studies?
Open accessAbstract
For the past century, experimental data obtained from animal studies have been required by reviewers of scientific articles and grant applications to validate the physiological relevance of in vitro results. At the same time, pharmaceutical researchers and regulatory agencies recognize that results from preclinical animal models frequently fail to predict drug responses in humans. This Progress Report reviews recent advances in human organ‐on‐a‐chip (Organ Chip) microfluidic culture technology, both with single Organ Chips and fluidically coupled human “Body‐on‐Chips” platforms, which demonstrate their ability to recapitulate human physiology and disease states, as well as human patient responses to clinically relevant drug pharmacokinetic exposures, with higher fidelity than other in vitro models or animal studies. These findings raise the question of whether continuing to require results of animal testing for publication or grant funding still makes scientific or ethical sense, and if more physiologically relevant human Organ Chip models might better serve this purpose. This issue is addressed in this article in context of the history of the field, and advantages and disadvantages of Organ Chip approaches versus animal models are discussed that should be considered by the wider research community.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Reconstituting organ-level lung functions on a chip
Huh, D., Matthews, B. D., Mammoto, A., Montoya-Zavala, M., Hsin, H. Y., & Ingber, D. E. (2010) · Science · doi:10.1126/science.1188302 · Cited by 4,250
Self-citationBhatia, S. N., & Ingber, D. E. (2014) · Nature Biotechnology · doi:10.1038/nbt.2989 · Cited by 3,305
Self-citationModeling Development and Disease with Organoids
Clevers, H. (2016) · Cell · doi:10.1016/j.cell.2016.05.082 · Cited by 3,196
Genomic responses in mouse models poorly mimic human inflammatory diseases
Seok, J., Warren, H. S., Cuenca, A. G., Mindrinos, M. N., Baker, H. V., Xu, W., Richards, D. R., McDonald-Smith, G. P., Gao, H., Hennessy, L., et al. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1222878110 · Cited by 3,005
Kim, H. J., Huh, D., Hamilton, G., & Ingber, D. E. (2012) · Lab on a Chip · doi:10.1039/c2lc40074j · Cited by 1,734
Self-citationOrganoid modeling of the tumor immune microenvironment
Neal, J. T., Li, X., Zhu, J., Giangarra, V., Grzeskowiak, C. L., Ju, J., Liu, I. H., Chiou, S.-H., Salahudeen, A. A., Smith, A. R., et al. (2018) · Cell · doi:10.1016/j.cell.2018.11.021 · Cited by 1,556
A Human Disease Model of Drug Toxicity–Induced Pulmonary Edema in a Lung-on-a-Chip Microdevice
Huh, D., Leslie, D. C., Matthews, B. D., Fraser, J. P., Jurek, S., Hamilton, G. A., Thorneloe, K. S., McAlexander, M. A., & Ingber, D. E. (2012) · Science Translational Medicine · doi:10.1126/scitranslmed.3004249 · Cited by 993
Self-citationFlow-enhanced vascularization and maturation of kidney organoids in vitro
Homan, K. A., Gupta, N., Kroll, K. T., Kolesky, D. B., Skylar-Scott, M., Miyoshi, T., Mau, D., Valerius, M. T., Ferrante, T., Bonventre, J. V., et al. (2019) · Nature Methods · doi:10.1038/s41592-019-0325-y · Cited by 939
Kim, H. J., Li, H., Collins, J. J., & Ingber, D. E. (2016) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1522193112 · Cited by 922
Self-citationMaschmeyer, I., Lorenz, A. K., Schimek, K., Hasenberg, T., Ramme, A. P., Hübner, J., Lindner, M., Drewell, C., Bauer, S., Thomas, A., et al. (2015) · Lab on a Chip · doi:10.1039/c5lc00392j · Cited by 861
Cited by
Recent progress in nanomedicine for enhanced cancer chemotherapy
Wei, G., Wang, Y., Yang, G., Wang, Y., & Ju, R. (2021) · Theranostics · doi:10.7150/thno.57828 · Cited by 463
Si, L., Bai, H., Rodas, M., Cao, W., Oh, C. Y., Jiang, A., Moller, R., Hoagland, D., Oishi, K., Horiuchi, S., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00718-9 · Cited by 440
“…therapeutics to move to humans, it is also important to note that human Organ Chips are now being explored as viable alternatives to animal models 51 and regulatory agencies are encouraging pharmaceutical and biotechnology companies to make use of data from Organ Chips and other…”
InfluentialSelf-citationMultiorgan-on-a-Chip: A Systemic Approach To Model and Decipher Inter-Organ Communication
Picollet-D’hahan, N., Zuchowska, A., Lemeunier, I., & Le Gac, S. (2021) · Trends in Biotechnology · doi:10.1016/j.tibtech.2020.11.014 · Cited by 379
Daly, A. C., Prendergast, M. E., Hughes, A. J., & Burdick, J. A. (2021) · Cell · doi:10.1016/j.cell.2020.12.002 · Cited by 332
Emerging Technologies in Multi‐Material Bioprinting
Ravanbakhsh, H., Karamzadeh, V., Bao, G., Mongeau, L., Juncker, D., & Zhang, Y. S. (2021) · Advanced Materials · doi:10.1002/adma.202104730 · Cited by 266
Metadata
- Authors
- Ingber, D. E.
- Venue
- Advanced Science
- Publisher
- Wiley
- Published
- 2020-10-12
- Volume
- 7
- Issue
- 22
- Pages
- 2002030-2002030
- ISSN
- 2198-3844 (ISSN-L)
- OpenAlex
- W3092983038
- Cited by
- 277
- References
- 80
- FWCI
- 12.39
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Is it Time for Reviewer 3 to Request Human Organ Chip Experiments Instead of Animal Validation Studies? https://app.cochat.ai/papers/10.1002/advs.202002030
- The paper
- Ingber, D. E. (2020). Is it Time for Reviewer 3 to Request Human Organ Chip Experiments Instead of Animal Validation Studies? Advanced Science. https://doi.org/10.1002/advs.202002030
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.