Cited by 9933D Printing in Biomedical ResearchMicrofluidic and Capillary Electrophoresis ApplicationsTissue Engineering and Regenerative Medicine

A Human Disease Model of Drug Toxicity–Induced Pulmonary Edema in a Lung-on-a-Chip Microdevice

Open access
Huh, Dongeun, Leslie, Daniel C., Matthews, Benjamin D., Fraser, Jacob P., Jurek, Samuel, Hamilton, Geraldine A., Thorneloe, Kevin S., McAlexander, Michael Allen +1 more·2012·Science Translational Medicine

Abstract

An in vitro model of human pulmonary edema predicts drug toxicity and efficacy previously observed in humans.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1126/scitranslmed.3004249

Cites

45 of 45 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Biomechanical stimuli such as shear stress, stretching or compression influence pathophysiological processes.

    “Biomechanical stimuli, such as shear stress, stretching or compression, influence (patho)physiological processes142–147”

    From Human disease models in drug development (2023) · cites this paper as [146]

    The Results section, “Pathological changes in barrier integrity” (page unavailable), shows that cyclic stretching during IL-2 exposure increased lung-barrier permeability and contributed to pulmonary edema. This supports stretching as an example of a biomechanical stimulus influencing a pathological process, but the cited paper does not establish the corresponding effects of shear stress or compression. (LLM, conf=0.84)

    Experimental — accuracy not yet measured
  • Using simple, direct modulation of TRPV4 with GSK101 in a 3D microfluidic system, vascular integrity can be tuned to recapitulate known TRPV4 physiological functions in vivo, especially in pulmonary edema, and achieve vascular leakiness comparable with previous MTM studies using tumor cells.

    “Using this simple, direct modulation of TRPV4 with GSK101 in a 3D micro fl uidic system, we can therefore tune the vascular integrity to recapitulate known TRPV4 physiological functions in vivo, especially in pulmonary edema, 28,30,51,52 and achieve vascular leakiness in a manner that is comparable with previous MTM studies using tumor cells. 2,53”

    From Rapid Assessment of Nanoparticle Extravasation in a Microfluidic Tumor Model (2019) · cites this paper as [53]

    Split into 2 atoms — 1 confirmed, 1 partially supported, 0 disputed, 0 misattributed, 0 unverifiable. Expand the claim to see per-atom verdicts.

    Experimental — accuracy not yet measured
  • HUVECs may not entirely recapitulate all known roles for TRPV4 in tumor vasculature.

    “HUVECs may not entirely recapitulate all known roles for TRPV4 in tumor vasculature. 24,28,35,51,53,66”

    From Rapid Assessment of Nanoparticle Extravasation in a Microfluidic Tumor Model (2019) · cites this paper as [53]

    The Results (‘Drug testing on-chip’; page unavailable) discuss TRPV4-mediated vascular leakage in a lung model, and the Methods (‘Microfluidic cell culture’; page unavailable) identify the cells as human pulmonary microvascular endothelial cells. Searches for HUVECs and tumor vasculature found no passage addressing whether HUVECs recapitulate TRPV4’s roles in tumor vessels. (LLM, conf=0.76)

    Experimental — accuracy not yet measured
  • Organ chip microdevices are able to recapitulate organ-level responses to toxins, drugs, radiation, cigarette smoke, pathogens, and normal microorganisms, as well as the dependence on flow-circulating immune cells and organs to recruit specific in vitro inflammatory responses.

    “Crucially, these organ chip microdevices are able to recapitulate organ-level responses to toxins79,96,97, drugs86,98, radiation99, cigarette smoke100, pathogens96, and normal microorganisms96, as well as the dependence on flow-circulating immune cells and organs to recruit specific in vitro inflammatory responses101, which are very important for preclinical drug screening and disease modeling.”

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Huh, D., Leslie, D. C., Matthews, B. D., Fraser, J. P., Jurek, S., Hamilton, G. A., Thorneloe, K. S., McAlexander, M. A., & Ingber, D. E.
Affiliations
  • Boston Children's Hospital (US)
  • Harvard University (US)
  • GlaxoSmithKline (United States) (US)
Corresponding author
Ingber, Donald E.
Venue
Science Translational Medicine
Published
2012-11-07
Volume
4
Issue
159
Pages
159ra147-159ra147
ISSN
  • 1946-6234 (ISSN-L)
  • 1946-6242
OpenAlex
W2124838743
Cited by
993
References
45
Citations by year
2026: 38 · 2025: 41 · 2024: 77 · 2023: 81 · 2022: 95 · 2021: 110 · 2020: 100 · 2019: 80 · 2018: 76 · 2017: 92 · 2016: 65 · 2015: 37 · 2014: 61 · 2013: 36 · 2012: 3
FWCI
24.96
Type
journal article
Language
en
Open access
Locations
  • Science Translational Medicine (publishedVersion)
  • PubMed (publishedVersion)
  • PubMed Central (acceptedVersion)
Funders
National Institute of Neurological Disorders and Stroke (U01NS073474)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
  • Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
  • Health Sciences › Medicine › Surgery › Tissue Engineering and Regenerative Medicine
Keywords
pulmonary edema, drug toxicity, interleukin-2, lung-on-a-chip, lung epithelial cells, pulmonary endothelial cells, mechanical strain, respiratory motion, vascular leakage, disease models, angiopoietin-1, GSK2193874, preclinical drug testing, alternatives to animal testing
MeSH terms
Animals, Biological Transport, Capillaries, Gases, Humans, Interleukin-2, Lung, Male, Mice, Inbred C57BL, Models, Biological, Pulmonary Edema, Blood-Air Barrier, Disease Progression, Microfluidic Analytical Techniques, Mice, In Vitro Techniques

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review