CoChat

A Photovoltaic Self‐Powered Gas Sensor Based on All‐Dry Transferred MoS2/GaSe Heterojunction for ppb‐Level NO2 Sensing at Room Temperature

Open access
Niu, Yue, Zeng, Junwei, Liu, Xiangcheng, Li, Jialong, Wang, Quan, Li, Hao, Rooij, Nicolaas Frans de, Wang, Yao, Zhou, Guofu · 2021 · Advanced Science
Cited by 164

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Traditional gas sensors are facing the challenge of low power consumption for future application in smart phones and wireless sensor platforms. To solve this problem, self‐powered gas sensors are rapidly developed in recent years. However, all reported self‐powered gas sensors are suffering from high limit of detection (LOD) toward NO 2 gas. In this work, a photovoltaic self‐powered NO 2 gas sensor based on n‐MoS 2/p‐GaSe heterojunction is successfully prepared by mechanical exfoliation and all‐dry transfer method. Under 405 nm visible light illumination, the fabricated photovoltaic self‐powered gas sensors show a significant response toward ppb‐level NO 2 with short response and recovery time and high selectivity at room temperature (25 °C). It is worth mentioning that the LOD toward NO 2 of this device is 20 ppb, which is the lowest of the reported self‐powered room‐temperature gas sensors so far. The discussed devices can be used as building blocks to fabricate more functional Internet of things devices.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/advs.202100472

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

Metadata

Authors
Niu, Y., Zeng, J., Liu, X., Li, J., Wang, Q., Li, H., Rooij, N. F. D., Wang, Y., & Zhou, G.
Venue
Advanced Science
Publisher
Wiley
Published
2021-05-24
Volume
8
Issue
14
Pages
e2100472-e2100472
ISSN
2198-3844 (ISSN-L)
OpenAlex
W3164470216
Cited by
164
References
2
FWCI
7.27
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.