Cited by 38Non-Invasive Vital Sign MonitoringSpectroscopy Techniques in Biomedical and Chemical ResearchPerovskite Materials and Applications

Highly Sensitive Perovskite Photoplethysmography Sensor for Blood Glucose Sensing Using Machine Learning Techniques

Open access
Zheng, Yongjian, Zhan, Zhenye, Chen, Qiulan, Chen, Jianxin, Luo, Jianwen, Cai, Juntao, Zhou, Yang, Chen, Ke +1 more·2024·Advanced Science

Abstract

Abstract Accurate non‐invasive monitoring of blood glucose (BG) is a challenging issue in the therapy of diabetes. Here near‐infrared (NIR) photoplethysmography (PPG) sensor based on a vapor‐deposited mixed tin‐lead hybrid perovskite photodetector is developed. The device shows a high detectivity of 5.32 × 1012 Jones and a large linear dynamic range (LDR) of 204 dB under NIR light, guaranteeing accurate extraction of eleven features from the PPG signal. By a combination of machine learning, accurate prediction of blood glucose level with mean absolute relative difference (MARD) as small as 2.48% is realized. The self‐powered PPG sensor also works for real‐time outdoor healthcare monitors using sunlight as a light source. The potential for early diabetes diagnoses by the perovskite PPG sensor is demonstrated.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/advs.202405681

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • With the rapid development of AI and IoT technologies, the efficient data acquisition and processing capabilities of perovskite sensors provide reliable technical support for smart devices in fields such as smart healthcare and smart homes, driving innovation and development in related industries.

    “With the rapid development of AI and IoT technologies, the efficient data acquisition and processing capabilities of perovskite sensors provide reliable technical support for smart devices in fields such as smart healthcare and smart homes, driving innovation and development in related industries [134].”

    From Design Strategies and Emerging Applications of Perovskite-Based Sensors (2025) · cites this paper as [134]

    The Introduction and Results describe a perovskite sensor that acquires PPG signals and uses machine learning to estimate blood glucose; the Discussion identifies potential for medical monitoring and future commercialization. The paper does not address IoT, smart homes, or innovation across related industries, so the broader claim exceeds its findings. (LLM, conf=0.87)

    Experimental — accuracy not yet measured
  • A near-infrared photoplethysmography (PPG) sensor was prepared using a vapor-deposited mixed tin-lead hybrid perovskite photodetector.

    “As illustrated in Figure 6C, a near-infrared photoplethysmography (PPG) sensor was prepared using a vapordeposited mixed tin-lead hybrid perovskite photodetector [134].”
  • The device demonstrated a high detectivity of 5.32 × 10^12 Jones and an impressive linear dynamic range of 204 dB under near-infrared light, enabling accurate extraction of 11 features from the PPG signal.

    “The device demonstrated a high detectivity of 5.32 × 10 12 Jones and an impressive linear dynamic range of 204 dB under near-infrared light, enabling accurate extraction of 11 features from the PPG signal techniques.”
  • Zheng et al. developed a near-infrared PPG sensor using a perovskite photodetector, achieving high detectivity (5.32 × 10^12 Jones) and a large dynamic range (204 dB).

    “Zheng et al. [134] developed a near-infrared PPG sensor using a perovskite photodetector, achieving high detectivity (5.32 × 10 12 Jones) and a large dynamic range (204 dB).”

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 45

  1. [1]A. Merovci, D. Tripathy, X. Chen, I. Valdez, M. Abdul‐Ghani, C. Solis‐Herrera, A. Gastaldelli, R. A. DeFronzo, Diabetes 2021, 70, 204. 33033064 PMC7881846
  2. [2]D. Bradshaw, R. Norman, D. Pieterse, N. S. Levitt, S. Afr. Med. J. 2007, 97, 700. 17952227
  3. [3]K. Castorino, S. Polsky, G. O'Malley, C. Levister, K. Nelson, C. Farfan, S. Brackett, S. Puhr, C. J. Levy, Diabetes Technol. Ther. 2020, 22, 943. 32324061 PMC7757524
  4. [4]M. Kosiborod, R. K. Gottlieb, J. A. Sekella, D. Peterman, A. Grodzinsky, P. Kennedy, M. A. Borkon, BMJ Open Diabetes Res. Care 2014, 2, e000037. PMC4212554 25452874
  5. [5]B. Grosman, N. Parikh, A. Roy, L. Lintereur, R. Vigersky, O. Cohen, A. Rhinehart, Ann. Biomed. Eng. 2023, 51, 211. 36125605
  6. [6]N. Lindner, A. Kuwabara, T. Holt, Syst. Rev. 2021, 10, 145. 33971958 PMC8111899
  7. [7]Y. Liu, Q. Yu, L. Ye, L. Yang, Y. Cui, Lab Chip 2023, 23, 421. 36597970
  8. [8]P. Jain, R. Maddila, A. M. Joshi, Opt. Quantum Electron. 2019, 51, 51.
  9. [9]A. Hina, W. Saadeh, IEEE Trans. Biomed. Circuits Syst. 2020, 14, 504. 32149655
  10. [10]J. Y. Sim, C.‐G. Ahn, E.‐J. Jeong, B. K. Kim, Sci. Rep. 2018, 8, 1059. 29348411 PMC5773698
  11. [11]A. M. K. Enejder, T. G. Scecina, J. Oh, M. Hunter, W.‐C. Shih, S. Sasic, G. L. Horowitz, M. S. Feld, J. Biomed. Opt. 2005, 10, 031114. 16229639
  12. [12]J. Li, J. Ma, O. M. Omisore, Y. Liu, H. Tang, P. Ao, Y. Yan, L. Wang, Z. Nie, IEEE Trans. Neural Netw. Learning Syst. 2023, 1, 10.1109/TNNLS.2023.3279383. 37289613 · DOI
  13. [13]J. Min, S. Demchyshyn, J. R. Sempionatto, Y. Song, B. Hailegnaw, C. Xu, Y. Yang, S. Solomon, C. Putz, L. E. Lehner, J. F. Schwarz, C. Schwarzinger, M. C. Scharber, E. Shirzaei Sani, M. Kaltenbrunner, W. Gao, Nat. Electron. 2023, 6, 630. 38465017 PMC10923186
  14. [14]A. Soni, S. K. Jha, Biosens. Bioelectron. 2015, 67, 763. 25282078
  15. [15]Sohmyung Ha, Chul Kim, Y. M. Chi, A. Akinin, C. Maier, A. Ueno, G. Cauwenberghs, IEEE Trans. Biomed. Eng. 2014, 61, 1522. 24759282
  16. [16]G. Hammour, D. P. Mandic, Sensors 2023, 23, 3319. 36992029 PMC10057625
  17. [17]S. Sen Gupta, T.‐H. Kwon, S. Hossain, K.‐D. Kim, Biomed. Signal Process. Control 2021, 68, 102706.
  18. [18]A. Prabha, J. Yadav, A. Rani, V. Singh, Comput. Biol. Med. 2021, 136, 104664. 34329866
  19. [19]E. Lee, C.‐Y. Lee, IEEE Sens. J. 2021, 21, 13564.
  20. [20]F. Liu, K. Liu, S. Rafique, Z. Xu, W. Niu, X. Li, Y. Wang, L. Deng, J. Wang, X. Yue, T. Li, J. Wang, P. Ayala, C. Cong, Y. Qin, A. Yu, N. Chi, Y. Zhan, Adv. Sci. 2023, 10, 2205879. PMC9929128 36494090
  21. [21]L. He, G. Hu, J. Jiang, W. Wei, X. Xue, K. Fan, H. Huang, L. Shen, Adv. Mater. 2023, 35, 2210016. 36512669
  22. [22]Z. Wu, J. Yang, X. Sun, Y. Wu, L. Wang, G. Meng, D. Kuang, X. Guo, W. Qu, B. Du, C. Liang, X. Fang, X. Tang, Y. He, Sens. Actuators, B 2021, 337, 129772.
  23. [23]Z. Chang, Z. Lu, W. Deng, Y. Shi, Y. Sun, X. Zhang, J. Jie, Nanoscale 2023, 15, 5053. 36805123
  24. [24]A. M. Joshi, P. Jain, S. P. Mohanty, N. Agrawal, IEEE Trans. Consumer Electron. 2020, 66, 327.
  25. [25]H. Li, J. Zhou, L. Tan, M. Li, C. Jiang, S. Wang, X. Zhao, Y. Liu, Y. Zhang, Y. Ye, W. Tress, C. Yi, Sci. Adv. 2022, 8, eabo7422. 35857518 PMC10942770
  26. [26]H. Li, L. Tan, C. Jiang, M. Li, J. Zhou, Y. Ye, Y. Liu, C. Yi, Adv. Funct. Mater. 2023, 33, 2211232.
  27. [27]Z. Zhan, D. Lin, J. Cai, Y. Lu, A. Chen, T. Zhang, K. Chen, P. Liu, X. Wang, W. Xie, Adv. Mater. 2022, 34, 2207106. 36193774
  28. [28]J. Yang, Q. Luo, S. Wu, Y. Li, Mate. Res. Appl. 2023, 17, 544.
  29. [29]D. Lin, Y. Gao, T. Zhang, Z. Zhan, N. Pang, Z. Wu, K. Chen, T. Shi, Z. Pan, P. Liu, W. Xie, Adv. Funct. Mater. 2022, 32, 2208392.
  30. [30]J. Tong, Q. Jiang, A. J. Ferguson, A. F. Palmstrom, X. Wang, J. Hao, S. P. Dunfield, A. E. Louks, S. P. Harvey, C. Li, H. Lu, R. M. France, S. A. Johnson, F. Zhang, M. Yang, J. F. Geisz, M. D. McGehee, M. C. Beard, Y. Yan, D. Kuciauskas, J. J. Berry, K. Zhu, Nat. Energy 2022, 7, 642.
  31. [31]W. Yang, N. Liao, H. Cheng, Y. Li, X. Bai, C. Deng, AIP Adv. 2018, 8, 035216.
  32. [32]Y. Uwadaira, A. Ikehata, A. Momose, M. Miura, Biomed. Opt. Express 2016, 7, 2729. 27446701 PMC4948625
  33. [33]W. L. Clarke, D. Cox, L. A. Gonder‐Frederick, W. Carter, S. L. Pohl, Diabetes Care 1987, 10, 622. 3677983
  34. [34]Y. Lu, S. J. Xie, S. Yoon, Z. Wang, D. S. Park, in 2013 6th International Congress on Image and Signal Processing (CISP), IEEE, Hangzhou, China 2013, pp. 410‐ 415.
  35. [35]C.‐Y. Liao, W.‐C. Fang, in 2023 IEEE International Symposium on Circuits and Systems (ISCAS), IEEE, Monterey, CA, USA 2023, 1‐ 5.
  36. [36]S. Alghlayini, A. Hosni, M. Atef, in 2023 Advances in Science and Engineering Technology International Conferences (ASET), IEEE, Dubai, UAE 2023, 1‐ 5.
  37. [37]R. Eslami, N. Azizi, S. R. Ghaffarian, M. Mehrvar, H. Zarrin, Electrochim. Acta 2022, 404, 139749.
  38. [38]W. Park, H. Seo, J. Kim, Y.‐M. Hong, H. Song, B. J. Joo, S. Kim, E. Kim, C.‐G. Yae, J. Kim, J. Jin, J. Kim, Y. Lee, J. Kim, H. K. Kim, J.‐U. Park, Nat. Commun. 2024, 15, 2828. 38565532 PMC10987615
  39. [39]D. Sankhala, A. U. Sardesai, M. Pali, K.‐C. Lin, B. Jagannath, S. Muthukumar, S. Prasad, Sci. Rep. 2022, 12, 2442. 35165316 PMC8844049
  40. [40]B. Feldman, R. Brazg, S. Schwartz, R. Weinstein, Diabetes Technol. Ther. 2003, 5, 769. 14633342
  41. [41]M. Mansour, M. Saeed Darweesh, A. Soltan, Alexandria Eng. J. 2024, 89, 224.
  42. [42]S. Song, Q. Wang, X. Zou, Z. Li, Z. Ma, D. Jiang, Y. Fu, Q. Liu, Spectrochim. Acta, Part A 2023, 303, 123176. 37494812
  43. [43]A. Pors, K. G. Rasmussen, R. Inglev, N. Jendrike, A. Philipps, A. G. Ranjan, V. Vestergaard, J. E. Henriksen, K. Nørgaard, G. Freckmann, K. D. Hepp, M. C. Gerstenberg, A. Weber, ACS Sens. 2023, 8, 1272. 36877178 PMC10043934
  44. [44]M. Naresh, V. S. Nagaraju, S. Kollem, J. Kumar, S. Peddakrishna, Heliyon 2024, 10, e28720. 38601525 PMC11004754
  45. [45]S. V. K. R. Rajeswari, P. Vijayakumar, Sci. Rep. 2024, 14, 9206. 38649731 PMC11035575

Cited by

Sorted by citations

Authors
Zheng, Y., Zhan, Z., Chen, Q., Chen, J., Luo, J., Cai, J., Zhou, Y., Chen, K., & Xie, W.
Affiliations
  • Jinan University (CN)
  • Guangdong Food and Drug Vocational College (CN)
  • First Affiliated Hospital of Jinan University (CN)
  • Guangzhou Research Institute of Optical Mechanical and Electronical Technologies Co.,Ltd Guangzhou Guangdong 510663 China
Corresponding author
Xie, Weiguang
Venue
Advanced Science
Publisher
Wiley
Published
2024-09-20
Volume
11
Issue
43
Pages
e2405681-e2405681
ISSN
2198-3844 (ISSN-L)
OpenAlex
W4402713265
Cited by
38
References
2
Citations by year
2026: 21 · 2025: 15 · 2024: 2
FWCI
4.17
Type
journal article
Language
en
Open access
Locations
  • Advanced Science (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
  • Basic and Applied Basic Research Foundation of Guangdong Province (2019B151502049)
  • National Natural Science Foundation of China (62174072)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Perovskite Materials and Applications
Keywords
photoplethysmography, blood glucose monitoring, perovskite photodetectors, near-infrared sensing, non-invasive glucose monitoring, diabetes mellitus, self-powered sensors, early detection of diabetes, detectivity, linear dynamic range
MeSH terms
Machine Learning, Blood Glucose, Diabetes Mellitus, Equipment Design, Humans, Oxides, Titanium, Photoplethysmography, Calcium Compounds

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review