Highly Self‐Adhesive and Biodegradable Silk Bioelectronics for All‐In‐One Imperceptible Long‐Term Electrophysiological Biosignals Monitoring
Open accessAbstract
Skin‐like bioelectronics offer a transformative technological frontier, catering to continuous and real‐time yet highly imperceptible and socially discreet digital healthcare. The key technological breakthrough enabling these innovations stems from advancements in novel material synthesis, with unparalleled possibilities such as conformability, miniature footprint, and elasticity. However, existing solutions still lack desirable properties like self‐adhesivity, breathability, biodegradability, transparency, and fail to offer a streamlined and scalable fabrication process. By addressing these challenges, inkjet‐patterned protein‐based skin‐like silk bioelectronics (Silk‐BioE) are presented, that integrate all the desirable material features that have been individually present in existing devices but never combined into a single embodiment. The all‐in‐one solution possesses excellent self‐adhesiveness (300 N m −1 ) without synthetic adhesives, high breathability (1263 g h −1 m −2 ) as well as swift biodegradability in soil within a mere 2 days. In addition, with an elastic modulus of ≈5 kPa and a stretchability surpassing 600%, the soft electronics seamlessly replicate the mechanics of epidermis and form a conformal skin/electrode interface even on hairy regions of the body under severe perspiration. Therefore, coupled with a flexible readout circuitry, Silk‐BioE can non‐invasively monitor biosignals (i.e., ECG, EEG, EOG) in real‐time for up to 12 h with benchmarking results against Ag/AgCl electrodes.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Yetisen, A. K., Martinez‐Hurtado, J. L., Ünal, B., Khademhosseini, A., & Butt, H. (2018) · Advanced Materials · doi:10.1002/adma.201706910 · Cited by 569 · see citing works
Plasticizing Silk Protein for On‐Skin Stretchable Electrodes
Chen, G., Matsuhisa, N., Liu, Z., Qi, D., Cai, P., Jiang, Y., Wan, C., Cui, Y., Leow, W. R., Liu, Z., et al. (2018) · Advanced Materials · doi:10.1002/adma.201800129 · Cited by 343 · see citing works
Flagged first, then by citations
- Authors
- Mirbakht, S. S., Golparvar, A., Umar, M., Kuzubasoglu, B. A., Irani, F. S., & Yapici, M. K.
- Affiliations
- Sabancı Üniversitesi (TR)
- Faculty of Engineering and Natural Sciences Sabanci University Istanbul 34956 Türkiye
- Corresponding author
- Yapici, Murat Kaya
- Venue
- Advanced Science
- Publisher
- Wiley
- Published
- 2025-01-10
- Volume
- 12
- Issue
- 8
- Pages
- e2405988-e2405988
- ISSN
- 2198-3844 (ISSN-L)
- PMC
- PMC11848544
- OpenAlex
- W4406237908
- Cited by
- 34
- References
- 2
- Citations by year
- 2026: 17 · 2025: 17
- FWCI
- 8.27
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Advanced Science (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Sabanci University (acceptedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
- Infoscience (Ecole Polytechnique Fédérale de Lausanne) (submittedVersion)
- Funders
- Bilim Akademisi (BAGEP'23)
- Türkiye Bilimler Akademisi (GEBIP'21)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Physical Sciences › Materials Science › Biomaterials › Silk-based biomaterials and applications
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Nanomaterials and Printing Technologies
- Keywords
- biodegradable electronics, ECG, EEG, electrooculography, stretchable electronics, breathability
- MeSH terms
- Wearable Electronic Devices, Adhesives, Animals, Biocompatible Materials, Equipment Design, Humans, Monitoring, Physiologic, Silk, Electrophysiological Phenomena
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review