The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Weft‐Knitted Fabric for a Highly Stretchable and Low‐Voltage Wearable Heater
Abstract
Wearable heaters have attracted broad attention due to their applications in personal heating systems and healthcare management, such as heat preservation in textile/clothing and thermotherapy. Protecting heating performance against deterioration under large deformation is is important for the application of wearable heaters. Here, a highly stretchable electrically driven heater based on electrically conductive weft‐knitted fabrics is reported, which can be transformed from traditional fabrics through a facile heat treatment process. As an example, a heater made from Modal shows a heating temperature higher than 100 °C at a driving voltage as low as 3 V. The Joule heating performance of the heater does not deteriorate even under a large strain of 70%. Furthermore, according to theoretical analysis and experimental results, the output power and saturated temperature of the heater under a certain voltage can be easily tuned by tailoring the shape and size of the fabric to meet customized demands. The superior performance of the heater originates from the weft‐knitted structural configuration. Finally, the application of the ultrastretchable heater in wearable thermal therapy devices is demonstrated, showing its great potential in wearable electronics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Trung, T. Q., & Lee, N. (2016) · Advanced Materials · doi:10.1002/adma.201504244 · Cited by 2,160
Choi, S., Park, J., Hyun, W., Kim, J., Kim, J., Lee, Y. B., Song, C., Hwang, H. J., Kim, J. H., Hyeon, T., et al. (2015) · ACS Nano · doi:10.1021/acsnano.5b02790 · Cited by 568
Cited by
Electronic Textiles for Wearable Point-of-Care Systems
Chen, G., Xiao, X., Zhao, X., Tat, T., Bick, M., & Chen, J. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00502 · Cited by 688
Mechanically Flexible Conductors for Stretchable and Wearable E‐Skin and E‐Textile Devices
Wang, B., & Facchetti, A. (2019) · Advanced Materials · doi:10.1002/adma.201901408 · Cited by 515
Zhao, X., Wang, L.-Y., Tang, C.-Y., Zha, X.-J., Liu, Y., Su, B.-H., Ke, K., Bao, R.-Y., Yang, M.-B., & Yang, W. (2020) · ACS Nano · doi:10.1021/acsnano.0c03391 · Cited by 511
Ma, Z., Xiang, X., Shao, L., Zhang, Y., & Gu, J. (2022) · Angewandte Chemie International Edition · doi:10.1002/anie.202200705 · Cited by 497
Self-citationMa, Z., Kang, S., Ma, J., Shao, L., Wei, A., Liang, C., Gu, J., Yang, B., Dong, D., Wei, L., et al. (2019) · ACS Nano · doi:10.1021/acsnano.9b00434 · Cited by 450
Metadata
- Authors
- Zhang, M., Wang, C., Liang, X., Yin, Z., Xia, K., Wang, H., Jian, M., & Zhang, Y.
- Venue
- Advanced Electronic Materials
- Publisher
- Wiley
- Published
- 2017-08-17
- Volume
- 3
- Issue
- 9
- ISSN
- 2199-160X (ISSN-L)
- OpenAlex
- W2748649782
- Cited by
- 171
- References
- 2
- FWCI
- 7.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.