Cited by 145Electrocatalysts for Energy ConversionIron oxide chemistry and applicationsCO2 Reduction Techniques and Catalysts

Hierarchically Structured 3D Integrated Electrodes by Galvanic Replacement Reaction for Highly Efficient Water Splitting

Wang, Jianying, Ji, Lvlv, Zuo, Shangshang, Chen, Zuofeng·2017·Advanced Energy Materials

Abstract

A NiFe‐based integrated electrode is fabricated by the spontaneous galvanic replacement reaction on an iron foam. Driven by the different electrochemical potentials between Ni and Fe, the dissolution of surface Fe occurs with electroless plating of Ni on iron foam with no need to access instrumentation and input energy. A facile cyclic voltammetry treatment is subsequently applied to convert the metallic NiFe to NiFeOx. A series of analytical methods indicates formation of a NiFeOx film of nanosheets on the iron foam surface. This hierarchically structured three dimensional electrode displays high activity and durability against water oxidation. In 1 m KOH, a current density of 1000 mA cm−2 is achieved at an overpotential of only 300 mV. This method is readily extended to fabricate CoFe or NiCoFe‐based integrated electrodes for water oxidation. Phosphorization of the bimetallic oxide (NiFeOx) generates the bimetallic phosphide (NiFe‐P), which can act as an excellent electrocatalyst for hydrogen production in 1 m KOH. An alkaline electrolyzer is constructed using NiFeOx and NiFe‐P coated iron foams as anode and cathode, which can realize overall water splitting with a current density of 100 mA cm−2 at an overpotential of 630 mV.

Integrity signals

Registry

Crossref · 10.1002/aenm.201700107

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Wang, J., Ji, L., Zuo, S., & Chen, Z.
Affiliations
Tongji University (CN)
Corresponding author
Chen, Zuofeng
Venue
Advanced Energy Materials
Publisher
Wiley
Published
2017-03-17
Volume
7
Issue
14
ISSN
  • 1614-6832 (ISSN-L)
  • 1614-6840
OpenAlex
W2595973141
Cited by
145
References
1
Citations by year
2026: 6 · 2025: 9 · 2024: 7 · 2023: 11 · 2022: 14 · 2021: 11 · 2020: 18 · 2019: 20 · 2018: 33 · 2017: 16
FWCI
6.37
Type
journal article
Language
en
Open access
closed
Locations
Advanced Energy Materials (publishedVersion)
Funders
  • National Natural Science Foundation of China (21573160, 21405114)
  • Science and Technology Commission of Shanghai Municipality (14DZ2261100)
Topics
  • Physical Sciences › Energy › Renewable Energy, Sustainability and the Environment › Electrocatalysts for Energy Conversion
  • Physical Sciences › Energy › Renewable Energy, Sustainability and the Environment › Iron oxide chemistry and applications
  • Physical Sciences › Energy › Renewable Energy, Sustainability and the Environment › CO2 Reduction Techniques and Catalysts
Keywords
galvanic replacement, electrocatalytic water oxidation, electroless nickel plating, iron foam, cyclic voltammetry, nanosheet films, bimetallic phosphides, overall water splitting, alkaline electrolyzer

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review