The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
High‐gradient magnetic separation of coated magnetic nanoparticles
Abstract
The feasibility is examined of using high‐gradient magnetic separation (HGMS) to recover about 8‐nm magnetite nanoparticles that are tailored specifically to extract target solutes (polymer‐coated nanoparticles for the extraction of soluble organic contaminants from water and phospholipid‐coated particles for the selective extraction of proteins). A general model for nanoparticle capture based on calculating the limit of static nanoparticle buildup around the wires in an HGMS column is presented. Model predictions are compared successfully with experimental results from a bench‐scale HGMS column for both the polymer‐ and phospholipid‐coated particles. A minimum diameter for successful particle capture is derived for both individually dispersed nanoparticles and aggregates of nanoparticles. The individually dispersed polymer‐coated nanoparticles are less easily captured in the HGMS column than are the phospholipid‐coated particles, which exist as submicron aggregates. © 2004 American Institute of Chemical Engineers AIChE J, 50: 2835–2848, 2004
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Colorimetric Determination of Iron with Disodium-1,2-dihydroxybenzene-3,5-disulfonate
YOE, J. H., & JONES, A. L. (1944) · Industrial & Engineering Chemistry Analytical Edition · doi:10.1021/i560126a015 · Cited by 1,038
Use of magnetic techniques for the isolation of cells
Šafařı́k, I., & Šafařı́ková, M. (1999) · Journal of Chromatography B: Biomedical Sciences and Applications · doi:10.1016/s0378-4347(98)00338-7 · Cited by 617
Bilayer Surfactant Stabilized Magnetic Fluids: Synthesis and Interactions at Interfaces
Shen, L., Laibinis, P. E., & Hatton, T. A. (1999) · Langmuir · doi:10.1021/la9807661 · Cited by 545
Self-citationProtein Separations Using Colloidal Magnetic Nanoparticles
Bucak, S., Jones, D. A., Laibinis, P. E., & Hatton, T. A. (2003) · Biotechnology Progress · doi:10.1021/bp0200853 · Cited by 324
Self-citationGeneralization of HGMS theory: The capture of ultra-fine particles
Gerber, R. A., Takayasu, M., & Friedlaender, F. (1983) · IEEE Transactions on Magnetics · doi:10.1109/tmag.1983.1062795 · Cited by 141
Fine particle high gradient magnetic entrapment
Fletcher, D. (1991) · IEEE Transactions on Magnetics · doi:10.1109/20.102936 · Cited by 84
Extractant-coated magnetic particles for cobalt and nickel recovery from acidic solution
Kaminski, M. D., & Nuñez, L. (1999) · Journal of Magnetism and Magnetic Materials · doi:10.1016/s0304-8853(98)00579-4 · Cited by 65
Šafařík, I. (1995) · Water Research · doi:10.1016/0043-1354(94)e0110-r · Cited by 60
Cited by
New Generation Adsorbents for Water Treatment
Ali, I. (2012) · Chemical Reviews · doi:10.1021/cr300133d · Cited by 1,758
Biological applications of magnetic nanoparticles
Colombo, M., Carregal-Romero, S., Casula, M. F., Gutiérrez, L., Morales, M. P., Böhm, I. B., Heverhagen, J. T., Prosperi, D., & Parak, W. J. (2012) · Chemical Society Reviews · doi:10.1039/c2cs15337h · Cited by 1,315
Low-Field Magnetic Separation of Monodisperse Fe 3 O 4 Nanocrystals
Yavuz, C. T., Mayo, J. T., Yu, W. W., Prakash, A., Falkner, J. C., Yean, S., Cong, L., Shipley, H. J., Kan, A., Tomson, M., et al. (2006) · Science · doi:10.1126/science.1131475 · Cited by 1,250
Spinel ferrite magnetic adsorbents: Alternative future materials for water purification?
Reddy, D. H. K., & Yun, Y.-S. (2016) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2016.01.012 · Cited by 792
Magnetic nanomaterials in catalysis: advanced catalysts for magnetic separation and beyond
Rossi, L. M., Costa, N. J. S., Silva, F. P., & Wojcieszak, R. (2014) · Green Chemistry · doi:10.1039/c4gc00164h · Cited by 624
Metadata
- Authors
- Moeser, G. D., Roach, K. A., Green, W. H., Alan Hatton, T., & Laibinis, P. E.
- Venue
- AIChE Journal
- Publisher
- Wiley
- Published
- 2004-10-08
- Volume
- 50
- Issue
- 11
- Pages
- 2835-2848
- ISSN
- 0001-1541 (ISSN-L)
- 1547-5905
- OpenAlex
- W2118603854
- Cited by
- 262
- References
- 8
- FWCI
- 8.16
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.