The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Characterization of gas crossover and its implications in PEM fuel cells
Abstract
With pure hydrogen as the fuel, PEM fuel cell operation at or near 100% fuel utilization is desirable to achieve a high stack efficiency and zero emissions. However, typical membranes used in PEM fuel cells allow a finite amount of permeation rates or crossover of hydrogen, oxygen, and nitrogen across the membrane. The hydrogen and oxygen that permeate through the membrane are consumed with the generation of heat and water but without the generating of useful work, leading to a fuel inefficiency. Nitrogen crossover, on the other hand, from the cathode side to the anode side accumulates at the exit of the anode flow fields, lowering the hydrogen concentration and resulting in local fuel starvation. In this study, an in‐situ electrochemical technique has been applied to determine the magnitude of the hydrogen crossover over a range of relevant fuel cell operating temperatures and pressures. Permeability coefficients thus obtained are compared to values reported in the literature. A mathematical model is developed to predict the extent of nitrogen accumulation along the anode flow fields, and fuel recycle as a mitigation method is simulated by improving hydrogen distribution. The model results were validated by comparison with experimental results. © 2006 American Institute of Chemical Engineers AIChE J, 2006
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gierke, T. D., Munn, G. E., & Wilson, F. C. (1981) · Journal of Polymer Science: Polymer Physics Edition · doi:10.1002/pol.1981.180191103 · Cited by 1,434
A Reverse-Current Decay Mechanism for Fuel Cells
Reiser, C. A., Bregoli, L., Patterson, T. W., Yi, J. S., Yang, J. D., Perry, M. L., & Jarvi, T. D. (2005) · Electrochemical and Solid-State Letters · doi:10.1149/1.1896466 · Cited by 976
Self-citationHandbook of fuel cells. Fundamentals technology and applications
Patrick, J. W. (2004) · Fuel · doi:10.1016/j.fuel.2003.09.012 · Cited by 739
Cation and Water Diffusion in Nafion Ion Exchange Membranes: Influence of Polymer Structure
Yeager, H. L., & Steck, A. (1981) · Journal of The Electrochemical Society · doi:10.1149/1.2127757 · Cited by 537
BROKA, K., & EKDUNGE, P. (1997) · Journal of Applied Electrochemistry · doi:10.1023/a:1018469520562 · Cited by 360
Gas Permeation Properties of Solid Polymer Electrolyte (SPE) Membranes
Sakai, T., Takenaka, H., Wakabayashi, N., Kawami, Y., & Torikai, E. (1985) · Journal of The Electrochemical Society · doi:10.1149/1.2114111 · Cited by 247
Parthasarathy, A., Martin, C. R., & Srinivasan, S. (1991) · Journal of The Electrochemical Society · doi:10.1149/1.2085747 · Cited by 240
Gas Diffusion in the Dried and Hydrated Nafions
Sakai, T., Takenaka, H., & Torikai, E. (1986) · Journal of The Electrochemical Society · doi:10.1149/1.2108551 · Cited by 227
Gas Permeation in SPE Method: II . Oxygen and Hydrogen Permeation Through Nafion
Ogumi, Z., Kuroe, T., & Takehara, Z. (1985) · Journal of The Electrochemical Society · doi:10.1149/1.2113631 · Cited by 202
Gas Permeation in SPE Method: I . Oxygen Permeation Through Nafion and NEOSEPTA
Ogumi, Z., Takehara, Z., & Yoshizawa, S. (1984) · Journal of The Electrochemical Society · doi:10.1149/1.2115696 · Cited by 189
Cited by
New Insights into Perfluorinated Sulfonic-Acid Ionomers
Kusoglu, A., & Weber, A. Z. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00159 · Cited by 2,432
Fuel Cell Catalyst Layers: A Polymer Science Perspective
Holdcroft, S. (2014) · Chemistry of Materials · doi:10.1021/cm401445h · Cited by 481
Lifetime prediction and the economic lifetime of Proton Exchange Membrane fuel cells
Chen, H., Pei, P., & Song, M. (2015) · Applied Energy · doi:10.1016/j.apenergy.2014.12.062 · Cited by 473
A comprehensive review of PBI-based high temperature PEM fuel cells
Araya, S. S., Zhou, F., Liso, V., Sahlin, S. L., Vang, J. R., Thomas, S., Gao, X., Jeppesen, C., & Kær, S. K. (2016) · International Journal of Hydrogen Energy · doi:10.1016/j.ijhydene.2016.09.024 · Cited by 463
Yousfi-Steiner, N., Moçotéguy, P., Candusso, D., & Hissel, D. (2009) · Journal of Power Sources · doi:10.1016/j.jpowsour.2009.03.060 · Cited by 431
Zhang, T., Wang, P., Chen, H., & Pei, P. (2018) · Applied Energy · doi:10.1016/j.apenergy.2018.04.049 · Cited by 416
Properties of Nafion membranes under PEM water electrolysis conditions
Ito, H., Maeda, T., Nakano, A., & Takenaka, H. (2011) · International Journal of Hydrogen Energy · doi:10.1016/j.ijhydene.2011.05.127 · Cited by 393
Rodgers, M. P., Bonville, L. J., Kunz, H. R., Slattery, D. K., & Fenton, J. M. (2012) · Chemical Reviews · doi:10.1021/cr200424d · Cited by 383
Diagnostic tools in PEM fuel cell research: Part I Electrochemical techniques
WU, J., YUAN, X., WANG, H., BLANCO, M., MARTIN, J., & ZHANG, J. (2008) · International Journal of Hydrogen Energy · doi:10.1016/j.ijhydene.2008.01.013 · Cited by 380
Pan, M., Pan, C., Li, C., & Zhao, J. (2021) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2021.110771 · Cited by 357
Properties of Nafion® NR-211 membranes for PEMFCs
Peron, J., Mani, A., Zhao, X., Edwards, D., Adachi, M., Soboleva, T., Shi, Z., Xie, Z., Navessin, T., & Holdcroft, S. (2010) · Journal of Membrane Science · doi:10.1016/j.memsci.2010.03.025 · Cited by 352
Gas Permeation through Nafion. Part 1: Measurements
Schalenbach, M., Hoefner, T., Paciok, P., Carmo, M., Lueke, W., & Stolten, D. (2015) · The Journal of Physical Chemistry C · doi:10.1021/acs.jpcc.5b04155 · Cited by 262
Baik, K. D., & Kim, M. S. (2011) · International Journal of Hydrogen Energy · doi:10.1016/j.ijhydene.2010.09.046 · Cited by 128
Gas-Crossover and Membrane-Pinhole Effects in Polymer-Electrolyte Fuel Cells
Weber, A. Z. (2008) · Journal of The Electrochemical Society · doi:10.1149/1.2898130 · Cited by 122
Numerical analysis of gas crossover effects in polymer electrolyte fuel cells (PEFCs)
Nam, J., Chippar, P., Kim, W., & Ju, H. (2010) · Applied Energy · doi:10.1016/j.apenergy.2010.05.023 · Cited by 82
Kundu, S., Fowler, M. W., Simon, L. C., Abouatallah, R., & Beydokhti, N. (2008) · Journal of Power Sources · doi:10.1016/j.jpowsour.2008.05.074 · Cited by 74
Hu, J., Sui, P. C., Kumar, S., & Djilali, N. (2009) · Electrochimica Acta · doi:10.1016/j.electacta.2009.04.073 · Cited by 61
A Multiparadigm Modeling Investigation of Membrane Chemical Degradation in PEM Fuel Cells
Quiroga, M. A., Malek, K., & Franco, A. A. (2016) · Journal of The Electrochemical Society · doi:10.1149/2.0931514jes · Cited by 50
Metadata
- Authors
- Kocha, S. S., Deliang Yang, J., & Yi, J. S.
- Venue
- AIChE Journal
- Publisher
- Wiley
- Published
- 2006-02-09
- Volume
- 52
- Issue
- 5
- Pages
- 1916-1925
- ISSN
- 0001-1541 (ISSN-L)
- 1547-5905
- OpenAlex
- W2134842273
- Cited by
- 362
- References
- 23
- FWCI
- 10.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.