The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Preparation of highly monodisperse droplet in a T‐junction microfluidic device
Abstract
In our previous work, a new flow route was developed—a so‐called perpendicular shear force–induced droplet formation—in a self‐designed simple T‐junction microchannel device. In this work, the crossflowing rupture technique was used to prepare monodisperse droplets in a similar device and successfully prepared monodisperse droplets ranging from 50 to 500 μm with polydispersity index (σ) values of <2%. Two kinds of flow patterns of plug flow and drop flow in the T‐junction microchannels could be formed. By changes in the surfactant concentration, the interfacial tension and the wetting ability varied, and the disordered or ordered two‐phase flow patterns could be controlled. Evolutions of the contact angle of the oil in contact with the wall surface were explained by the adsorption of surfactant molecules to the solid–liquid interface. The increase of continuous phase flow rate and viscosity resulted in the decrease of the droplet size, and the droplet size was correlated with capillary number Ca. By comparing the variation range of drop size using the two methods, it was found that the method of perpendicular flow‐induced droplet formation can control the drop size over a much wider range. © 2006 American Institute of Chemical Engineers AIChE J, 2006
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Formation of dispersions using “flow focusing” in microchannels
Anna, S. L., Bontoux, N., & Stone, H. A. (2003) · Applied Physics Letters · doi:10.1063/1.1537519 · Cited by 2,302
Dynamic Pattern Formation in a Vesicle-Generating Microfluidic Device
Thorsen, T., Roberts, R. W., Arnold, F. H., & Quake, S. R. (2001) · Physical Review Letters · doi:10.1103/physrevlett.86.4163 · Cited by 2,051
Geometrically Mediated Breakup of Drops in Microfluidic Devices
Link, D. R., Anna, S. L., Weitz, D. A., & Stone, H. A. (2004) · Physical Review Letters · doi:10.1103/physrevlett.92.054503 · Cited by 1,202
Screening of Protein Crystallization Conditions on a Microfluidic Chip Using Nanoliter-Size Droplets
Zheng, B., Roach, L. S., & Ismagilov, R. F. (2003) · Journal of the American Chemical Society · doi:10.1021/ja037166v · Cited by 697
Millisecond Kinetics on a Microfluidic Chip Using Nanoliters of Reagents
Song, H., & Ismagilov, R. F. (2003) · Journal of the American Chemical Society · doi:10.1021/ja0354566 · Cited by 693
Monodisperse Emulsion Generation via Drop Break Off in a Coflowing Stream
Umbanhowar, P. B., Prasad, V., & Weitz, D. A. (2000) · Langmuir · doi:10.1021/la990101e · Cited by 693
Droplet formation in a microchannel network
Nisisako, T., Torii, T., & Higuchi, T. (2002) · Lab Chip · doi:10.1039/b108740c · Cited by 607
Membrane emulsification — a literature review
Joscelyne, S. M., & Trägårdh, G. (2000) · Journal of Membrane Science · doi:10.1016/s0376-7388(99)00334-8 · Cited by 576
Tan, Y.-C., Fisher, J. S., Lee, A. I., Cristini, V., & Lee, A. P. (2004) · Lab on a Chip · doi:10.1039/b403280m · Cited by 509
The intensification of rapid reactions in multiphase systems using slug flow in capillaries
Burns, J. R., & Ramshaw, C. (2001) · Lab on a Chip · doi:10.1039/b102818a · Cited by 503
Ordered and Disordered Patterns in Two-Phase Flows in Microchannels
Dreyfus, R., Tabeling, P., & Willaime, H. (2003) · Physical Review Letters · doi:10.1103/physrevlett.90.144505 · Cited by 404
Regular‐sized cell creation in microchannel emulsification by visual microprocessing method
Kawakatsu, T., Kikuchi, Y., & Nakajima, M. (1997) · Journal of the American Oil Chemists' Society · doi:10.1007/s11746-997-0143-8 · Cited by 396
Effects of viscosity on droplet formation and mixing in microfluidic channels
Tice, J. D., Lyon, A. D., & Ismagilov, R. F. (2004) · Analytica Chimica Acta · doi:10.1016/j.aca.2003.11.024 · Cited by 360
Silicon array of elongated through‐holes for monodisperse emulsion droplets
Kobayashi, I., Nakajima, M., Chun, K., Kikuchi, Y., & Fujita, H. (2002) · AIChE Journal · doi:10.1002/aic.690480807 · Cited by 246
Shear Rupturing of Droplets in Complex Fluids
Mason, T. G., & Bibette, J. (1997) · Langmuir · doi:10.1021/la9700580 · Cited by 245
Xu, J. H., Luo, G. S., Li, S. W., & Chen, G. G. (2006) · Lab Chip · doi:10.1039/b509939k · Cited by 235
Self-citationA Prototype Two-Dimensional Capillary Electrophoresis System Fabricated in Poly(dimethylsiloxane)
Chen, X., Wu, H., Mao, C., & Whitesides, G. M. (2002) · Analytical Chemistry · doi:10.1021/ac0109422 · Cited by 138
Cited by
Teh, S.-Y., Lin, R., Hung, L.-H., & Lee, A. P. (2008) · Lab on a Chip · doi:10.1039/b715524g · Cited by 2,690
Passive and active droplet generation with microfluidics: a review
Zhu, P., & Wang, L. (2017) · Lab on a Chip · doi:10.1039/c6lc01018k · Cited by 1,238
Seemann, R., Brinkmann, M., Pfohl, T., & Herminghaus, S. (2012) · Reports on Progress in Physics · doi:10.1088/0034-4885/75/1/016601 · Cited by 1,049
Microfluidic methods for generating continuous droplet streams
Christopher, G. F., & Anna, S. L. (2007) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/40/19/r01 · Cited by 860
Microdroplets: A sea of applications?
Huebner, A., Sharma, S., Srisa-Art, M., Hollfelder, F., Edel, J. B., & deMello, A. J. (2008) · Lab on a Chip · doi:10.1039/b806405a · Cited by 619
Metadata
- Authors
- Xu, J. H., Li, S. W., Tan, J., Wang, Y. J., & Luo, G. S.
- Venue
- AIChE Journal
- Publisher
- Wiley
- Published
- 2006-06-15
- Volume
- 52
- Issue
- 9
- Pages
- 3005-3010
- ISSN
- 0001-1541 (ISSN-L)
- 1547-5905
- OpenAlex
- W1991726404
- Cited by
- 335
- References
- 17
- FWCI
- 8.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.