The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Quality‐relevant and process‐relevant fault monitoring with concurrent projection to latent structures
Abstract
This paper proposes a new concurrent projection to latent structures is proposed in this paper for the monitoring of output‐relevant faults that affect the quality and input‐relevant process faults. The input and output data spaces are concurrently projected to five subspaces, a joint input‐output subspace that captures covariations between input and output, an output‐principal subspace, an output‐residual subspace, an input‐principal subspace, and an input‐residual subspace. Fault detection indices are developed based on these subspaces for various fault detection alarms. The proposed monitoring method offers complete monitoring of faults that happen in the predictable output subspace and the unpredictable output residual subspace, as well as faults that affect the input spaces only. Numerical simulation examples and the Tennessee Eastman challenge problem are used to illustrate the effectiveness of the proposed method. © 2012 American Institute of Chemical Engineers AIChE J, 59: 496–504, 2013
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Partial least-squares regression: a tutorial
Geladi, P., & Kowalski, B. R. (1986) · Analytica Chimica Acta · doi:10.1016/0003-2670(86)80028-9 · Cited by 6,992
A plant-wide industrial process control problem
Downs, J. J., & Vogel, E. F. (1993) · Computers & Chemical Engineering · doi:10.1016/0098-1354(93)80018-i · Cited by 3,348
A Use's Guide to Principal Components
Jackson, J. E. (1991) · Wiley Series in Probability and Statistics · doi:10.1002/0471725331 · Cited by 2,516
Orthogonal projections to latent structures (O‐PLS)
Trygg, J., & Wold, S. (2002) · Journal of Chemometrics · doi:10.1002/cem.695 · Cited by 2,447
SIMPLS: An alternative approach to partial least squares regression
de Jong, S. (1993) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/0169-7439(93)85002-x · Cited by 1,905
Höskuldsson, A. (1988) · Journal of Chemometrics · doi:10.1002/cem.1180020306 · Cited by 1,881
Statistical process monitoring: basics and beyond
Joe Qin, S. (2003) · Journal of Chemometrics · doi:10.1002/cem.800 · Cited by 1,582
Box, G. E. P. (1954) · The Annals of Mathematical Statistics · doi:10.1214/aoms/1177728786 · Cited by 1,513
Fault Detection and Diagnosis in Industrial Systems
Chiang, L. H., Russell, E. L., & Braatz, R. D. (2001) · Advanced Textbooks in Control and Signal Processing · doi:10.1007/978-1-4471-0347-9 · Cited by 1,318
Control Procedures for Residuals Associated With Principal Component Analysis
Jackson, J. E., & Mudholkar, G. S. (1979) · Technometrics · doi:10.1080/00401706.1979.10489779 · Cited by 1,237
Orthogonal signal correction of near-infrared spectra
Wold, S., Antti, H., Lindgren, F., & Öhman, J. (1998) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/s0169-7439(98)00109-9 · Cited by 1,089
Multivariate statistical monitoring of process operating performance
Kresta, J. V., Macgregor, J. F., & Marlin, T. E. (1991) · The Canadian Journal of Chemical Engineering · doi:10.1002/cjce.5450690105 · Cited by 989
The process chemometrics approach to process monitoring and fault detection
Wise, B. M., & Gallagher, N. B. (1996) · Journal of Process Control · doi:10.1016/0959-1524(96)00009-1 · Cited by 852
Process monitoring and diagnosis by multiblock PLS methods
MacGregor, J. F., Jaeckle, C., Kiparissides, C., & Koutoudi, M. (1994) · AIChE Journal · doi:10.1002/aic.690400509 · Cited by 773
Identification of faulty sensors using principal component analysis
Dunia, R., Qin, S. J., Edgar, T. F., & McAvoy, T. J. (1996) · AIChE Journal · doi:10.1002/aic.690421011 · Cited by 526
Self-citationTotal projection to latent structures for process monitoring
Zhou, D., Li, G., & Qin, S. J. (2010) · AIChE Journal · doi:10.1002/aic.11977 · Cited by 472
Self-citationSubspace approach to multidimensional fault identification and reconstruction
Dunia, R. H., & Qin, S. J. (1998) · AIChE Journal · doi:10.1002/aic.690440812 · Cited by 382
Self-citationContribution plots: a missing link in multivariate quality control
Miller, P. C., Swanson, R. E., & Heckler, C. E. (1998) · International Journal of Applied Mathematics and Computer Science · Cited by 374
Geometric properties of partial least squares for process monitoring
Li, G., Qin, S. J., & Zhou, D. (2010) · Automatica · doi:10.1016/j.automatica.2009.10.030 · Cited by 368
Self-citationJoint diagnosis of process and sensor faults using principal component analysis
Dunia, R., & Joe Qin, S. (1998) · Control Engineering Practice · doi:10.1016/s0967-0661(98)00027-6 · Cited by 251
Detection, identification, and reconstruction of faulty sensors with maximized sensitivity
Qin, S. J., & Li, W. (1999) · AIChE Journal · doi:10.1002/aic.690450913 · Cited by 140
Self-citation
Cited by
A Review on Basic Data-Driven Approaches for Industrial Process Monitoring
Yin, S., Ding, S. X., Xie, X., & Luo, H. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2301773 · Cited by 1,716
Data Mining and Analytics in the Process Industry: The Role of Machine Learning
Ge, Z., Song, Z., Ding, S. X., & Huang, B. (2017) · IEEE Access · doi:10.1109/access.2017.2756872 · Cited by 922
“Qin and Zheng [159] formulated a concurrent form of the PLS model, and used it for quality-relevant and processrelevant fault monitoring.”
BackgroundReview on data-driven modeling and monitoring for plant-wide industrial processes
Ge, Z. (2017) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/j.chemolab.2017.09.021 · Cited by 630
Process data analytics in the era of big data
Qin, S. J. (2014) · AIChE Journal · doi:10.1002/aic.14523 · Cited by 383
Self-citationAdvances and opportunities in machine learning for process data analytics
Qin, S. J., & Chiang, L. H. (2019) · Computers & Chemical Engineering · doi:10.1016/j.compchemeng.2019.04.003 · Cited by 351
Self-citation
Metadata
- Authors
- Qin, S. J., & Zheng, Y.
- Venue
- AIChE Journal
- Publisher
- Wiley
- Published
- 2012-12-20
- Volume
- 59
- Issue
- 2
- Pages
- 496-504
- ISSN
- 0001-1541 (ISSN-L)
- 1547-5905
- OpenAlex
- W2128921897
- Cited by
- 263
- References
- 21
- FWCI
- 16.23
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.