Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 282

The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.

CO2 capture from dry flue gas by vacuum swing adsorption: A pilot plant study

Krishnamurthy, Shreenath, Rao, Vemula Rama, Guntuka, Sathishkumar, Sharratt, Paul, Haghpanah, Reza, Rajendran, Arvind, Amanullah, Mohammad, Karimi, Iftekhar A., Farooq, Shamsuzzaman·2014·AIChE Journal

Abstract

The capture and concentration of CO 2 from a dry flue gas by vacuum swing adsorption (VSA) has been experimentally demonstrated in a pilot plant. The pilot plant has the provision for using two coupled columns that are each packed with approximately 41 kg of Zeochem zeolite 13X. Breakthrough experiments were first carried out by perturbing a N 2 saturated bed with 15% CO 2 and 85% N 2 feed, which is representative of a dry flue gas from coal‐fired power plants. The breakthrough results showed long plateaus in temperature profiles confirming a near adiabatic behavior. In the process study, a basic four‐step vacuum swing adsorption (VSA) cycle comprising the following steps: pressurization with feed, adsorption, forward blowdown, and reverse evacuation was investigated first. In the absence of any coupling among the steps, a single bed was used. With this cycle configuration, CO 2 was concentrated to 95.9 ± 1% with a recovery of 86.4 ± 5.6%. To improve the process performance, a four‐step cycle with light product pressurization (LPP) using two beds was investigated. This cycle was able to achieve 94.8 ± 1% purity and 89.7 ± 5.6% recovery. The Department of Energy requirements are 95% purity and 90% recovery. The proposed underlying physics of performance improvement of the four‐step cycle with LPP has also been experimentally validated. The pilot plant results were then used for detailed validation of a one‐dimensional, nonisothermal, and nonisobaric model. Both transient profiles of various measured variables and cyclic steady state performance results were compared with the model predictions, and they were in good agreement. The energy consumptions in the pilot plant experiments were 339–583 ± 36.7 kWh tonne−1 CO 2 captured and they were significantly different from the theoretical power consumptions obtained from isentropic compression calculations. The productivities were 0.87–1.4 ± 0.07 tonne CO 2 m−3 adsorbent day−1. The results from our pilot plant were also compared with available results from other pilot plant studies on CO 2 capture from flue gas. © 2014 American Institute of Chemical Engineers AIChE J, 60: 1830–1842, 2014

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/aic.14435

Cites

23 of 23 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 282

Metadata

Authors
Krishnamurthy, S., Rao, V. R., Guntuka, S., Sharratt, P., Haghpanah, R., Rajendran, A., Amanullah, M., Karimi, I. A., & Farooq, S.
Venue
AIChE Journal
Publisher
Wiley
Published
2014-03-20
Volume
60
Issue
5
Pages
1830-1842
ISSN
  • 0001-1541 (ISSN-L)
  • 1547-5905
OpenAlex
W2155684877
Cited by
282
References
23
FWCI
22.99
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.