Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 268

The DOI matches its Crossref record.

Drop size distribution in agitated liquid‐liquid systems

Chen, Hsiao Tsung, Middleman, Stanley·1967·AIChE Journal

Abstract

The drop size distributions resulting from the agitation of immiscible liquids were measured over a wide range of parameters. The average drop size is correlated by \documentclass{article}\pagestyle{empty}\begin{document}$ \overline D _{32}/L $\end{document} = 0.053 NWe−0.60. The distribution function for volume fraction is normal and depends only upon \documentclass{article}\pagestyle{empty}\begin{document}$ \overline D _{32} $\end{document}. The results are valid for very dilute solutions wherein coalescence of droplets plays no role in the dispersion mechanism.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/aic.690130529

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 268

Metadata

Authors
Chen, H. T., & Middleman, S.
Venue
AIChE Journal
Publisher
Wiley
Published
1967-09
Volume
13
Issue
5
Pages
989-995
ISSN
  • 0001-1541 (ISSN-L)
  • 1547-5905
OpenAlex
W1984482077
Cited by
268
References
0
FWCI
1.53
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Drop size distribution in agitated liquid‐liquid systems. https://app.cochat.ai/papers/10.1002/aic.690130529
The paper
Chen, H. T., & Middleman, S. (1967). Drop size distribution in agitated liquid‐liquid systems. AIChE Journal. https://doi.org/10.1002/aic.690130529

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.