The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Adsorption rate constants from chromatography
Abstract
A new method for determining adsorption equilibrium constants, rate constants, and intraparticle diffusivities is described and applied for the adsorption of ethane, propane, and n‐butane on silica gel. The method rests upon recently developed theory for relating the moments of the effluent concentration wave from a bed of adsorbent particles to the rate constants associated with the various steps in the overall adsorption process. It is necessary to operate at concentrations of adsorbable gas such that the adsorption isotherm is linear. However, it is possible to take into account effects of longitudinal dispersion and diffusion to the particle surface as well as the intraparticle processes of diffusion and adsorption on the pore surface. The method gave reasonable values for intraparticle diffusivities and adsorption rate constants. Intraparticle diffusion was a major resistance for all particle sizes studied and for the largest size (R = 0.50 mm.) this step controlled the overall rate. From the constants determined chromatographically it is possible to predict breakthrough curves for the adsorption of these hydrocarbons on silica gel. The predicted curves agree well with experimentally established breakthrough curves.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The properties of gases and liquids
Kobe, K. A. (1959) · Journal of Chemical Education · doi:10.1021/ed036p154.4 · Cited by 2,761
Contribution to the theory of chromatography
Kučera, E. (1965) · Journal of Chromatography A · doi:10.1016/s0021-9673(01)99457-9 · Cited by 491
The role of diffusion in catalysis
Satterfield, C. N., & SHERWOOD, T. K. (1963) · Cited by 396
Kinetics of a Fixed Bed System for Solid Diffusion into Spherical Particles
Rosen, J. B. (1952) · The Journal of Chemical Physics · doi:10.1063/1.1700431 · Cited by 341
Cited by
Choi, J.-G., Do, D. D., & Do, H. D. (2001) · Industrial & Engineering Chemistry Research · doi:10.1021/ie010195z · Cited by 284
Column versus batch methods for measuring PFOS and PFOA sorption to geomedia
Van Glubt, S., Brusseau, M. L., Yan, N., Huang, D., Khan, N., & Carroll, K. C. (2021) · Environmental Pollution · doi:10.1016/j.envpol.2020.115917 · Cited by 87
Kopaç, T. (1999) · Chemical Engineering and Processing: Process Intensification · doi:10.1016/s0255-2701(98)00069-5 · Cited by 37
DYNAMIC ADSORPTION OF S02 ON ZEOLITE MOLECULAR SIEVES†
KOPAQ∗, T., KAYMAKgi, E., & KOPAC, M. (1998) · Chemical Engineering Communications · doi:10.1080/00986449808912360 · Cited by 20
Metadata
- Authors
- Schneider, P., & Smith, J. M.
- Venue
- AIChE Journal
- Publisher
- Wiley
- Published
- 1968-09
- Volume
- 14
- Issue
- 5
- Pages
- 762-771
- ISSN
- 0001-1541 (ISSN-L)
- 1547-5905
- OpenAlex
- W2167932277
- Cited by
- 352
- References
- 4
- FWCI
- 4.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Adsorption rate constants from chromatography. https://app.cochat.ai/papers/10.1002/aic.690140516
- The paper
- Schneider, P., & Smith, J. M. (1968). Adsorption rate constants from chromatography. AIChE Journal. https://doi.org/10.1002/aic.690140516
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.