Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 164

The DOI matches its Crossref record.

Mapping the cavitation intensity in an ultrasonic bath using the acoustic emission

Moholkar, Vijayanand S., Sable, Shishir P., Pandit, Aniruddha B. · 2000 · AIChE Journal

Abstract

A new method for separate identification and determination of the spatial distribution of the two components of the energy intensity in an ultrasound bath (due to the ultrasound waves and cavitation activity) uses two media—cavitating (water) and noncavitating (silicon oil)—under the conditions of the acoustic field in the ultrasound bath. The variation of cavitation intensity in the frequency domain was obtained by subtracting the acoustic emission spectrum of silicon oil from that of water. Measurements at various locations in the bath revealed significant spatial variations in the cavitation intensity in the bath. The local cavitation phenomena in the bath (stable or transient cavitation) were explained based on the spectral characteristics of acoustic emission. The radial dynamics of the bubbles at the location of cavitation intensity measurements was determined using the Gilmore model of bubble dynamics. The bubbles in the region of highest cavitation intensity underwent a transient motion, while the bubbles in the region of lowest cavitation intensity underwent stable/oscillatory motion. The transient collapse of the bubbles that gives rise to local temperature and pressure maxima is at the root of the observed effects of ultrasound on chemical systems. The more violent the collapse of the bubbles, the higher the local cavitation intensity. It was verified using the spectral characteristics of the acoustic emission and simulation of the radial motion of the bubbles.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/aic.690460404

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 164

Metadata

Authors
Moholkar, V. S., Sable, S. P., & Pandit, A. B.
Venue
AIChE Journal
Publisher
Wiley
Published
2000-04
Volume
46
Issue
4
Pages
684-694
ISSN
  • 0001-1541 (ISSN-L)
  • 1547-5905
OpenAlex
W1989478189
Cited by
164
References
0
FWCI
1.42
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Mapping the cavitation intensity in an ultrasonic bath using the acoustic emission. https://app.cochat.ai/papers/10.1002/aic.690460404
The paper
Moholkar, V. S., Sable, S. P., & Pandit, A. B. (2000). Mapping the cavitation intensity in an ultrasonic bath using the acoustic emission. AIChE Journal. https://doi.org/10.1002/aic.690460404

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.