Numerical simulation of operational parameters and sonoreactor configurations for the highest possibility of acoustic cavitation in crude oil
Abstract
Pressure distribution, caused by ultrasonic wave propagation, has a crucial effect on the efficiency of a sonoreactor for crude oil upgrading. In this study, acoustic pressure distribution was computed by numerical solution of the acoustic wave propagation equation in a crude oil sonoreactor. By analyzing numerical simulation results, optimum geometrical and operational parameters, comprising type and probe size, probe depth in bulk of crude oil, dimensions, shape of reactor, frequency, and sound power, were evaluated for the highest possibility of cavitation, chemical, and physical changes. Moreover, the effect of probe location on pressure distribution was investigated. The results show the important effect of probe location on pressure distribution due to change of wave reflection angles.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
To attain intended cavitation effect, ultrasonic intensity should be amplified with rising frequency to overcome cohesiveness in the mixture.
“In order to attain the intended cavitation effect, the ultrasonic intensity should be amplified with rising frequency to conquer the cohesiveness in the mixture [57].”
From A comprehensive review of ultrasonic assisted extraction (UAE) for bioactive components: Principles, advantages, equipment, and combined technologies (2023) · cites this paper as [57]
Cites
Mason, T. J., & Lorimer, J. P. (2002) · Wiley eBooks · doi:10.1002/352760054x · Cited by 1,508 · see citing works
Acoustic cavitation and its chemical consequences
Suslick, K. S., Didenko, Y. T., Fang, M. M., Hyeon, T., Kolbeck, K. J., McNamara, W. B., Mdleleni, M. M., & Wong, M. (1999) · Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences · doi:10.1098/rsta.1999.0330 · Cited by 811 · see citing works
Cavitation : A technology on the horizon
Gogate, P. R., Tayal, R. K., & Pandit, A. B. (2006) · Cited by 172 · see citing works
Mapping the cavitation intensity in an ultrasonic bath using the acoustic emission
Moholkar, V. S., Sable, S. P., & Pandit, A. B. (2000) · AIChE Journal · doi:10.1002/aic.690460404 · Cited by 165 · see citing works
Klı́ma, J., Frías‐Ferrer, Á., González‐García, J., et al. (2006) · Ultrasonics Sonochemistry · doi:10.1016/j.ultsonch.2006.01.001 · Cited by 160 · see citing works
(2008) · Wiley eBooks · doi:10.1002/9783527623501 · Cited by 135 · see citing works
Quantification of cavitation intensity in fluid bulk
Chivate, M. M., & Pandit, A. B. (1995) · Ultrasonics Sonochemistry · doi:10.1016/1350-4177(94)00007-f · Cited by 110 · see citing works
Investigation of acoustic cavitation energy in a large-scale sonoreactor
Son, Y., Lim, M., & Khim, J. (2008) · Ultrasonics Sonochemistry · doi:10.1016/j.ultsonch.2008.12.004 · Cited by 101 · see citing works
Bernal, V. S., Frías‐Ferrer, Á., Iniesta, J., et al. (2004) · Ultrasonics Sonochemistry · doi:10.1016/j.ultsonch.2004.06.011 · Cited by 96 · see citing works
Chemical reactions under ultrasound: discrimination of chemical and physical effects
Contamine, F., Faı̈d, F., Wilhelm, A. M., et al. (1994) · Chemical Engineering Science · doi:10.1016/0009-2509(94)00297-5 · Cited by 93 · see citing works
Effects of Ultrasound Treatment on the Upgradation of Heavy Gas Oil
Gopinath, R., Dalai, A. K., & Adjaye, J. D. (2005) · Energy & Fuels · doi:10.1021/ef050231x · Cited by 56 · see citing works
Meng, G., Jaworski, A. J., & White, N. M. (2005) · Chemical Engineering and Processing - Process Intensification · doi:10.1016/j.cep.2005.10.004 · Cited by 56 · see citing works
Use of ultrasound in petroleum residue upgradation
Sawarkar, A. N., Pandit, A. B., Samant, S. D., et al. (2009) · The Canadian Journal of Chemical Engineering · doi:10.1002/cjce.20169 · Cited by 37 · see citing works
Effect of ultrasound irradiation on solvent extraction process
Kim, H., Chi, M.-H., & Hong, I.-K. (2009) · Journal of Industrial and Engineering Chemistry · doi:10.1016/j.jiec.2009.09.025 · Cited by 30 · see citing works
The possibility of cracking hydrocarbons with cavitation. A quantitative energy assessment
Нестеренко, О. И., & Berlizov, Y. S. (2007) · Chemistry and Technology of Fuels and Oils · doi:10.1007/s10553-007-0089-4 · Cited by 19 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Ultrasound: A clean, green extraction technology
Tiwari, B. K. (2015) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2015.04.013 · Cited by 1,042 · see citing works
Shen, L., Pang, S., Zhong, M., Sun, Y., Qayum, A., Liu, Y., Rashid, A., Xu, B., Liang, Q., Ma, H., et al. (2023) · Ultrasonics Sonochemistry · doi:10.1016/j.ultsonch.2023.106646 · Cited by 892 · see citing works
“In order to attain the intended cavitation effect, the ultrasonic intensity should be amplified with rising frequency to conquer the cohesiveness in the mixture [57].”
Background
- Authors
- Niazi, S., Hashemabadi, S. H., & Noroozi, S.
- Affiliations
- Iran University of Science and Technology (IR)
- Corresponding author
- Hashemabadi, S. H.
- ORCID
- Niazi, S.
- Venue
- Chemical Engineering Communications
- Publisher
- Informa UK Limited
- Published
- 2014-05-29
- Volume
- 201
- Issue
- 10
- Pages
- 1340-1359
- ISSN
- 0098-6445 (ISSN-L)
- 1563-5201
- OpenAlex
- W2104235584
- Cited by
- 16
- References
- 15
- Citations by year
- 2025: 1 · 2024: 1 · 2023: 1 · 2022: 1 · 2021: 2 · 2020: 5 · 2019: 3 · 2017: 1 · 2015: 1
- FWCI
- 0.30
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Chemical Engineering Communications (publishedVersion)
- Topics
- Physical Sciences › Materials Science › Materials Chemistry › Ultrasound and Cavitation Phenomena
- Physical Sciences › Chemistry › Analytical Chemistry › Petroleum Processing and Analysis
- Physical Sciences › Engineering › Biomedical Engineering › Ultrasound and Hyperthermia Applications
- Keywords
- acoustic cavitation, crude oil upgrading, sonoreactor, ultrasonic wave propagation, sound pressure distribution, probe location, probe size, reactor geometry, acoustic power, wave reflection
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review