Equilibrium and diffusion of methanol and water in a nafion 117 membrane
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
The uptake concentrations of methanol and water in a Nafion membrane are measured as a function of methanol mol fraction from a liquid methanol–water mixture. The results are fitted by a thermodynamically consistent equation, derived from an expression of the Gibbs energy. The uptake of pure methanol and pure water from the vapor phase is measured as a function of vapor pressure. A discontinuity, known in the literature as Schroeder's paradox, between membrane uptakes of pure methanol and pure water from the liquid and vapor phases is noted. Regions of unconditional instability are enveloped by spinodal loci for the ternary mixture in the membrane when equilibrated with liquid mixtures. The effective diffusion coefficient is measured at 60°C for diffusion from a vapor into a saturated Nafion membrane. The effective diffusion coefficients are found to be on the order of 10−11 m 2/s, which is comparable to other measurements made for diffusion of a vapor through the membrane.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Water Uptake by and Transport Through Nafion® 117 Membranes
Zawodzinski, T. A., Derouin, C., Radzinski, S., Sherman, R. J., Smith, V. T., Springer, T. E., & Gottesfeld, S. (1993) · Journal of The Electrochemical Society · doi:10.1149/1.2056194 · Cited by 1,530
Determination of water diffusion coefficients in perfluorosulfonate ionomeric membranes
Zawodzinski, T. A., Neeman, M., Sillerud, L. O., & Gottesfeld, S. (1991) · The Journal of Physical Chemistry · doi:10.1021/j100168a060 · Cited by 987
A Comparative Study of Water Uptake By and Transport Through Ionomeric Fuel Cell Membranes
Zawodzinski, T. A., Springer, T. E., Davey, J., Jestel, R., Lopez, C., Valerio, J., & Gottesfeld, S. (1993) · Journal of The Electrochemical Society · doi:10.1149/1.2220749 · Cited by 661
Water Uptake of Perfluorosulfonic Acid Membranes from Liquid Water and Water Vapor
Hinatsu, J. T., Mizuhata, M., & Takenaka, H. (1994) · Journal of The Electrochemical Society · doi:10.1149/1.2054951 · Cited by 518
Cited by
New Insights into Perfluorinated Sulfonic-Acid Ionomers
Kusoglu, A., & Weber, A. Z. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00159 · Cited by 2,432
Transport in Polymer-Electrolyte Membranes
Weber, A. Z., & Newman, J. (2004) · Journal of The Electrochemical Society · doi:10.1149/1.1639157 · Cited by 462
Self-citationTransport in Polymer-Electrolyte Membranes
Weber, A. Z., & Newman, J. (2003) · Journal of The Electrochemical Society · doi:10.1149/1.1580822 · Cited by 411
Self-citationProperties of Nafion® NR-211 membranes for PEMFCs
Peron, J., Mani, A., Zhao, X., Edwards, D., Adachi, M., Soboleva, T., Shi, Z., Xie, Z., Navessin, T., & Holdcroft, S. (2010) · Journal of Membrane Science · doi:10.1016/j.memsci.2010.03.025 · Cited by 352
Water sorption, desorption and transport in Nafion membranes
Majsztrik, P. W., Satterfield, M. B., Bocarsly, A. B., & Benziger, J. B. (2007) · Journal of Membrane Science · doi:10.1016/j.memsci.2007.06.022 · Cited by 348
Metadata
- Authors
- Gates, C. M., & Newman, J.
- Venue
- AIChE Journal
- Publisher
- Wiley
- Published
- 2000-10
- Volume
- 46
- Issue
- 10
- Pages
- 2076-2085
- ISSN
- 0001-1541 (ISSN-L)
- 1547-5905
- OpenAlex
- W2098729974
- Cited by
- 80
- References
- 4
- FWCI
- 3.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.