Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 216

The DOI matches its Crossref record.

Mapping of sonochemical reactors: Review, analysis, and experimental verification

Gogate, Parag R., Tatake, Prashant A., Kanthale, Parag M., Pandit, Aniruddha B.·2002·AIChE Journal

Abstract

The erratic behavior of cavitational activity exhibited in a sonochemical reactor poses a serious problem in its design and scale‐up. Several previous studies in the past dealt with mapping of sonochemical reactors, which have been critically analyzed and recommended for efficient scale‐up strategies. There have been no efforts to link the primary effects (local pressure field) of ultrasound activity with the observed secondary effects (such as chemical reaction). In this work an ultrasonic horn (standard immersion‐type reactor), and an ultrasonic bath (rectangular geometry with transducers located at the bottom in triangular pitch) reactors were mapped with the help of local pressure measurement (using a hydrophone), and liberated iodine was estimated using the Weissler reaction, and a quantitative relationship was established between the two. In estimating chemical reaction rates, the effect of microscopic variation in the type of microreactor used (test tube in this case) on the extent of degradation was also investigated. Measured local pressure pulses were used in theoretical simulations of bubble dynamics equations to check the type of cavitation taking place locally, and to estimate the possible collapse of the pressure pulse in terms of the maximum bubble size reached during the cavitation phenomena. A relationship also was established between observed iodine liberation rates and the maximum bubble size reached. The engineers can easily use these unique relationships in an efficient design, since the secondary effect can be directly quantified.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/aic.690480717

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 216

Metadata

Authors
Gogate, P. R., Tatake, P. A., Kanthale, P. M., & Pandit, A. B.
Venue
AIChE Journal
Publisher
Wiley
Published
2002-07
Volume
48
Issue
7
Pages
1542-1560
ISSN
  • 0001-1541 (ISSN-L)
  • 1547-5905
OpenAlex
W2131043124
Cited by
216
References
0
FWCI
3.51
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Mapping of sonochemical reactors: Review, analysis, and experimental verification. https://app.cochat.ai/papers/10.1002/aic.690480717
The paper
Gogate, P. R., Tatake, P. A., Kanthale, P. M., & Pandit, A. B. (2002). Mapping of sonochemical reactors: Review, analysis, and experimental verification. AIChE Journal. https://doi.org/10.1002/aic.690480717

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.