The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Magnetic Continuum Device with Variable Stiffness for Minimally Invasive Surgery
Open accessAbstract
One of the challenges of minimally invasive surgery is the dexterous manipulation and precise control of small‐diameter continuum surgical instruments. Herein, a magnetic continuum device with variable stiffness (VS) is presented, whose tip is precisely shaped and controlled using an external magnetic field. Based on a low melting point alloy (LMPA), the serial segments composing the continuum device are independently softened via electrical current and remotely deformed under a magnetic torque, whereas the rest of the device is locked in place. The resulting system has the advantage of combining the precision of magnetic navigation with additional degrees of freedom provided by changing the segments stiffness. With a minimum diameter as small as 2.33 mm and an inner working channel, the magnetic continuum device with VS is adapted to use in several therapeutic scenarios, including radio‐frequency cardiac ablations and interventional endoscopy in the gastrointestinal tract. The magnetic torque is used to remotely control the shape of the soft sections, whereas the stiff sections remain unchanged, thus adding degrees of freedom to the magnetic continuum device.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Review of progress in shape-memory polymers
Liu, C., Qin, H., & Mather, P. T. (2007) · Journal of Materials Chemistry · doi:10.1039/b615954k · Cited by 1,942
Cited by
Magnetic Soft Materials and Robots
Kim, Y., & Zhao, X. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00481 · Cited by 873
Functional Fibers and Fabrics for Soft Robotics, Wearables, and Human–Robot Interface
Xiong, J., Chen, J., & Lee, P. S. (2021) · Advanced Materials · doi:10.1002/adma.202002640 · Cited by 627
Magnetic Actuation Systems for Miniature Robots: A Review
Yang, Z., & Zhang, L. (2020) · Advanced Intelligent Systems · doi:10.1002/aisy.202000082 · Cited by 388
Magnetic Actuation Methods in Bio/Soft Robotics
Ebrahimi, N., Bi, C., Cappelleri, D. J., Ciuti, G., Conn, A. T., Faivre, D., Habibi, N., Hošovský, A., Iacovacci, V., Khalil, I. S. M., et al. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202005137 · Cited by 353
Yasa, O., Toshimitsu, Y., Michelis, M. Y., Jones, L. S., Filippi, M., Buchner, T., & Katzschmann, R. K. (2023) · Annual Review of Control, Robotics, and Autonomous Systems · doi:10.1146/annurev-control-062322-100607 · Cited by 290
Metadata
- Authors
- Chautems, C., Tonazzini, A., Boehler, Q., Jeong, S. H., Floreano, D., & Nelson, B. J.
- Venue
- Advanced Intelligent Systems
- Publisher
- Wiley
- Published
- 2019-10-03
- Volume
- 2
- Issue
- 6
- ISSN
- 2640-4567 (ISSN-L)
- OpenAlex
- W2973098377
- Cited by
- 193
- References
- 1
- FWCI
- 4.89
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Magnetic Continuum Device with Variable Stiffness for Minimally Invasive Surgery. https://app.cochat.ai/papers/10.1002/aisy.201900086
- The paper
- Chautems, C., Tonazzini, A., Boehler, Q., Jeong, S. H., Floreano, D., & Nelson, B. J. (2020). Magnetic Continuum Device with Variable Stiffness for Minimally Invasive Surgery. Advanced Intelligent Systems. https://doi.org/10.1002/aisy.201900086
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.