Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 193

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Magnetic Continuum Device with Variable Stiffness for Minimally Invasive Surgery

Open access
Chautems, Christophe, Tonazzini, Alice, Boehler, Quentin, Jeong, Seung Hee, Floreano, Dario, Nelson, Bradley J. · 2020 · Advanced Intelligent Systems

Abstract

One of the challenges of minimally invasive surgery is the dexterous manipulation and precise control of small‐diameter continuum surgical instruments. Herein, a magnetic continuum device with variable stiffness (VS) is presented, whose tip is precisely shaped and controlled using an external magnetic field. Based on a low melting point alloy (LMPA), the serial segments composing the continuum device are independently softened via electrical current and remotely deformed under a magnetic torque, whereas the rest of the device is locked in place. The resulting system has the advantage of combining the precision of magnetic navigation with additional degrees of freedom provided by changing the segments stiffness. With a minimum diameter as small as 2.33 mm and an inner working channel, the magnetic continuum device with VS is adapted to use in several therapeutic scenarios, including radio‐frequency cardiac ablations and interventional endoscopy in the gastrointestinal tract. The magnetic torque is used to remotely control the shape of the soft sections, whereas the stiff sections remain unchanged, thus adding degrees of freedom to the magnetic continuum device.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/aisy.201900086

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 193

Metadata

Authors
Chautems, C., Tonazzini, A., Boehler, Q., Jeong, S. H., Floreano, D., & Nelson, B. J.
Venue
Advanced Intelligent Systems
Publisher
Wiley
Published
2019-10-03
Volume
2
Issue
6
ISSN
2640-4567 (ISSN-L)
OpenAlex
W2973098377
Cited by
193
References
1
FWCI
4.89
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Magnetic Continuum Device with Variable Stiffness for Minimally Invasive Surgery. https://app.cochat.ai/papers/10.1002/aisy.201900086
The paper
Chautems, C., Tonazzini, A., Boehler, Q., Jeong, S. H., Floreano, D., & Nelson, B. J. (2020). Magnetic Continuum Device with Variable Stiffness for Minimally Invasive Surgery. Advanced Intelligent Systems. https://doi.org/10.1002/aisy.201900086

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.