Magnetically Actuated Continuum Medical Robots: A Review
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The magnetic field has unique advantages in manipulating miniature robots working inside the human body, such as high transparency to biological tissue and good controllability for field generation. Generally, the actuated magnetic robot can be classified into two categories: tethered devices like intravascular microcatheters and untethered devices like helical swimmers. Among these, the tethered devices have a long history and good clinical application prospects, considering their high‐dose delivery and easy removal after the procedure. As an evolution of traditional continuum medical devices, the integration with magnetic actuation provides them with better scalability and improved dexterity. Although rapidly developed in the last two decades, the field of tethered magnetic robots requires further advancements in terms of design, fabrication, modeling, and control, especially for clinical applications. Herein, the recent progress of magnetically actuated continuum medical robots is focused on, intending to offer readers a comprehensive survey of the state‐of‐the‐art technologies and an information collection for future system design.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biomedical applications of soft robotics
Cianchetti, M., Laschi, C., Menciassi, A., & Dario, P. (2018) · Nature Reviews Materials · doi:10.1038/s41578-018-0022-y · Cited by 1,435
Ferromagnetic soft catheter robots for minimally invasive bioprinting
Zhou, C., Yang, Y., Wang, J., Wu, Q., Gu, Z., Zhou, Y., Liu, X., Yang, Y., Tang, H., Ling, Q., et al. (2021) · Nature Communications · doi:10.1038/s41467-021-25386-w · Cited by 242
Cited by
Zhang, M., Yang, L., Yang, H., Su, L., Xue, J., Wang, Q., Hao, B., Jiang, Y., Chan, K. F., Sung, J. J. Y., et al. (2025) · Science Advances · doi:10.1126/sciadv.adv1682 · Cited by 36
Self-citation
Metadata
- Authors
- Yang, Z., Yang, H., Cao, Y., Cui, Y., & Zhang, L.
- Venue
- Advanced Intelligent Systems
- Publisher
- Wiley
- Published
- 2023-03
- Volume
- 5
- Issue
- 6
- ISSN
- 2640-4567 (ISSN-L)
- OpenAlex
- W4322773318
- Cited by
- 165
- References
- 2
- FWCI
- 12.10
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Magnetically Actuated Continuum Medical Robots: A Review. https://app.cochat.ai/papers/10.1002/aisy.202200416
- The paper
- Yang, Z., Yang, H., Cao, Y., Cui, Y., & Zhang, L. (2023). Magnetically Actuated Continuum Medical Robots: A Review. Advanced Intelligent Systems. https://doi.org/10.1002/aisy.202200416
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.