A magnetically actuated microcatheter with soft rotatable tip for enhanced endovascular access and treatment efficiency

Open access

Abstract

Endovascular interventions require fast access to affected regions, followed by effective treatment. Catheterizations are effective approaches for treating vascular diseases; however, they face challenges in accessibility, efficiency, and invasiveness in narrow, tortuous vascular systems. This study presents a submillimeter magnetically actuated soft rotatable-tipped microcatheter (MSRM) designed to access small blood vessels and provide efficient, minimally invasive therapeutic interventions for blood clot treatment. The MSRM’s rotatable tip design enhances accessibility and navigation speed through a rotation-assisted active steering strategy. Improved blood clot treatment efficiency is achieved through the MSRM’s multifunctionality: It can accelerate drug-blood clot interactions, mechanically break down blood clots, and retrieve clot debris. The low invasiveness is attributed to the soft material design and conservative actuation strategy. The performance of the MSRM is validated in both in vitro phantom studies and in vivo rabbit models, and the invasiveness is evaluated using a human placenta model.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1126/sciadv.adv1682

Cites

80 of 80 references verified0 citation errors · 0 not checkable

Statistics

Figures

Fig. 1. Design of the magnetic microcatheter system for endovascular treatments. (A) Exploded view of the microcatheter design. (B) MSRM prototype that is compared to a one-dollar Hong Kong dollar coin. The inset shows the microscopic view. (C) Schematic illustration of the rotation-assisted steering strategy and its advantages. (i to iii) Convention method to navigate the microcatheter to the sharp turn branch where the friction on the tip could cause the catheter to buckle. (iv) Rotational motion at the tip releases the contact friction at the tip and smooths the insertion process. (D). Schematic diagram of the magnetically actuated microcatheter system working principle. The magnetically actuated microcatheter can efficiently navigate through narrow blood vessels and generate therapeutic interventions from three aspects: drug-clot interaction acceleration (E), rotational mechanical breakdown (F), and clot debris retrieval (G).
Fig. 1. Design of the magnetic microcatheter system for endovascular treatments. (A) Exploded view of the microcatheter design. (B) MSRM prototype that is compared to a one-dollar Hong Kong dollar coin. The inset shows the microscopic view. (C) Schematic illustration of the rotation-assisted steering strategy and its advantages. (i to iii) Convention method to navigate the microcatheter to the sharp turn branch where the friction on the tip could cause the catheter to buckle. (iv) Rotational motion at the tip releases the contact friction at the tip and smooths the insertion process. (D). Schematic diagram of the magnetically actuated microcatheter system working principle. The magnetically actuated microcatheter can efficiently navigate through narrow blood vessels and generate therapeutic interventions from three aspects: drug-clot interaction acceleration (E), rotational mechanical breakdown (F), and clot debris retrieval (G).CC BY · PubMed Central
Fig. 2. Rotation-assisted active steering strategy. (A) Key experiment frames of using rotation-assisted steering strategy to enter the sharp-turn branch. (i and ii) The directional field guides the microcatheter’s tip to the entrance. The stuck at the tip results in tension accumulation on the body of the catheter. (iii) Further advancement caused failure to enter the branch. (iv) Rotation motion decreases the friction force at the tip and directs the microcatheter to the desired branch. The magnetic field directions are marked by the purple arrows. (B) Keyframes of the experiment using the DMF to guide the microcatheter to the bifurcation phantom and the reachable workspace comparison between the DMF steering method (DMF-guided) and RMF-guided steering method (RMF-guided). A maximum 50% reachable workspace enhancement is observed at a magnetic field of 25 mT. Color areas represent the bending range of the microcatheter in the branch phantom. (C) Insertion force comparisons between passive insertion and rotation-assisted insertion through navigating a sharp turn. The L-shaped channel is divided into three segments by the point from A to D. In the rotation-assisted group, the norm direction of the rotation field θn is determined by the trajectory tangent direction. The branch angle θt = 90° describes the sharpness of the corner. (D) Results of the insertion force comparison that shows the RMF-guided group requires the least force compared to the DMF-guided group, commercial guidewire group, and nonguided group. The force reduction in segment C to D highlights friction release due to rotational motion, with color bands representing SD and lines depicting mean values. Each group of tests is repeated five times. (E) Required RMF strength when the microcatheter is in various branch angles.
Fig. 2. Rotation-assisted active steering strategy. (A) Key experiment frames of using rotation-assisted steering strategy to enter the sharp-turn branch. (i and ii) The directional field guides the microcatheter’s tip to the entrance. The stuck at the tip results in tension accumulation on the body of the catheter. (iii) Further advancement caused failure to enter the branch. (iv) Rotation motion decreases the friction force at the tip and directs the microcatheter to the desired branch. The magnetic field directions are marked by the purple arrows. (B) Keyframes of the experiment using the DMF to guide the microcatheter to the bifurcation phantom and the reachable workspace comparison between the DMF steering method (DMF-guided) and RMF-guided steering method (RMF-guided). A maximum 50% reachable workspace enhancement is observed at a magnetic field of 25 mT. Color areas represent the bending range of the microcatheter in the branch phantom. (C) Insertion force comparisons between passive insertion and rotation-assisted insertion through navigating a sharp turn. The L-shaped channel is divided into three segments by the point from A to D. In the rotation-assisted group, the norm direction of the rotation field θn is determined by the trajectory tangent direction. The branch angle θt = 90° describes the sharpness of the corner. (D) Results of the insertion force comparison that shows the RMF-guided group requires the least force compared to the DMF-guided group, commercial guidewire group, and nonguided group. The force reduction in segment C to D highlights friction release due to rotational motion, with color bands representing SD and lines depicting mean values. Each group of tests is repeated five times. (E) Required RMF strength when the microcatheter is in various branch angles.CC BY · PubMed Central
Fig. 3. Rotational actuation design and simulation results. (A) Different tip designs: cylinder, straight fins, and helical fins with different rotation directions. (B) Side edge pressure distribution with respect to the distance to the catheter’s rear end at 5 Hz. (C) Pressure distribution of retrieving mode and pumping mode. (D) Simulation results to optimize the structural design of the rotatable tip. The optimal values are θp = 60° and α = 45°. (E) Simulation settings to investigate the optimal tip profile. (F) Simulation result that shows the affected area of different tip profile designs. (G) Pumping effect comparing with natural diffusion at rotation velocity of 5 Hz. Each group of tests is repeated three times. (H) Schematic flow status of the pumping mode and retrieving mode.
Fig. 3. Rotational actuation design and simulation results. (A) Different tip designs: cylinder, straight fins, and helical fins with different rotation directions. (B) Side edge pressure distribution with respect to the distance to the catheter’s rear end at 5 Hz. (C) Pressure distribution of retrieving mode and pumping mode. (D) Simulation results to optimize the structural design of the rotatable tip. The optimal values are θp = 60° and α = 45°. (E) Simulation settings to investigate the optimal tip profile. (F) Simulation result that shows the affected area of different tip profile designs. (G) Pumping effect comparing with natural diffusion at rotation velocity of 5 Hz. Each group of tests is repeated three times. (H) Schematic flow status of the pumping mode and retrieving mode.CC BY · PubMed Central
Fig. 4. In vitro accessibility verification. (A) In vitro navigation in full-size human cerebral blood vessel model. Two regions of interest are as follows: (i) the M3 to M4 transition region of the MCA and (ii) the S-shape tortuous blood vessel of the ICA. (B) Dimension details of the phantom region (i). (C) Dimension details of the phantom region (ii). R1 and R2 are the curvature radius of the first and the second turn, respectively. (D) Keyframes of navigation in the region (i). The microcatheter navigated two bifurcations and arrived at two destinations in the distal branches. The red arrow highlights the position of the microcatheter tip. (E) Keyframes of navigation in region (ii). The microcatheter passes two continuous 180° turns with small radius curvature. Scale bar, 5 mm. (F) Navigation efficiency comparison of the region (i). Each group of tests is repeated 10 times. (G) Navigation efficiency comparison of the region (ii). Each group of tests is repeated 10 times.
Fig. 4. In vitro accessibility verification. (A) In vitro navigation in full-size human cerebral blood vessel model. Two regions of interest are as follows: (i) the M3 to M4 transition region of the MCA and (ii) the S-shape tortuous blood vessel of the ICA. (B) Dimension details of the phantom region (i). (C) Dimension details of the phantom region (ii). R1 and R2 are the curvature radius of the first and the second turn, respectively. (D) Keyframes of navigation in the region (i). The microcatheter navigated two bifurcations and arrived at two destinations in the distal branches. The red arrow highlights the position of the microcatheter tip. (E) Keyframes of navigation in region (ii). The microcatheter passes two continuous 180° turns with small radius curvature. Scale bar, 5 mm. (F) Navigation efficiency comparison of the region (i). Each group of tests is repeated 10 times. (G) Navigation efficiency comparison of the region (ii). Each group of tests is repeated 10 times.CC BY · PubMed Central
Fig. 5. Endovascular treatment functions validation. (A) Experiment results to verify the blood clot–drug interaction enhancement. Clots are examined at intervals to assess volume reduction. (B) Treatment efficiency comparison using three methods to treat blood clots ( ϕ 2 mm × 5 mm, 30 min). Each group of tests is repeated three times. (C) Mechanical rubbing blood clot clearing efficiency at different speeds. The blood clot dimension: ϕ 2 mm × 5 mm. Each group of tests is repeated three times. (D) Schematic working principle and experimental demonstration of the blood clot retrieval strategy. (E) Blood clot retrieval efficiency on blood clots of different lengths. The retrieval time starts when the microcatheter exits and ends once all clot debris is collected. Each group of tests is repeated three times. (F) Blood clot retrieval efficiency and mechanical rubbing efficiency on blood clots of different ages. The retrieval time starts when the microcatheter exits and ends once all clot debris is collected. The rotating frequency is 5 Hz. Each group of tests is repeated three times.
Fig. 5. Endovascular treatment functions validation. (A) Experiment results to verify the blood clot–drug interaction enhancement. Clots are examined at intervals to assess volume reduction. (B) Treatment efficiency comparison using three methods to treat blood clots ( ϕ 2 mm × 5 mm, 30 min). Each group of tests is repeated three times. (C) Mechanical rubbing blood clot clearing efficiency at different speeds. The blood clot dimension: ϕ 2 mm × 5 mm. Each group of tests is repeated three times. (D) Schematic working principle and experimental demonstration of the blood clot retrieval strategy. (E) Blood clot retrieval efficiency on blood clots of different lengths. The retrieval time starts when the microcatheter exits and ends once all clot debris is collected. Each group of tests is repeated three times. (F) Blood clot retrieval efficiency and mechanical rubbing efficiency on blood clots of different ages. The retrieval time starts when the microcatheter exits and ends once all clot debris is collected. The rotating frequency is 5 Hz. Each group of tests is repeated three times.CC BY · PubMed Central
Fig. 6. In vivo demonstrations in a rabbit model. (A) Two key regions: the carotid artery region and the iliac artery to kidney region. (B) System setup for x-ray imaging guided in vivo microcatheter navigation. (C) In vivo navigation to kidney artery. The dashed line highlights the desired trajectory and the bifurcation branches are highlighted in blue. Scale bar, 10 mm. (D) Navigation with static field actuation. The microcatheter can be steered toward the desired branch, but large friction at the tip may cause buckling on the microcatheter, as the arrow shows. (E) Navigation with rotational field guidance. The rotation-assisted steering mechanism can facilitate a smoother insertion process with a shorter duration and less tension on the catheter body. (F) System setup for in vivo blood clot clearance. (G) Preoperative stage of the in vivo blood clot clearance demonstration. The selected segment of the carotid artery is ligated at one end and connected to a catheter sheath at the other. In the preoperative stage, the blood clot is inserted through the sheath, filling the artery to the ligature site. (H) Intraoperative blood clot clearance demonstration. The microcatheter advanced deeper every 5 min. After 15 min, the blood clot is thoroughly broken down. (I) Postoperative stage of the in vivo blood clot clearance demonstration. The blood clot has disappeared from the imaging plane and cannot be observed after inflating the blood vessel.
Fig. 6. In vivo demonstrations in a rabbit model. (A) Two key regions: the carotid artery region and the iliac artery to kidney region. (B) System setup for x-ray imaging guided in vivo microcatheter navigation. (C) In vivo navigation to kidney artery. The dashed line highlights the desired trajectory and the bifurcation branches are highlighted in blue. Scale bar, 10 mm. (D) Navigation with static field actuation. The microcatheter can be steered toward the desired branch, but large friction at the tip may cause buckling on the microcatheter, as the arrow shows. (E) Navigation with rotational field guidance. The rotation-assisted steering mechanism can facilitate a smoother insertion process with a shorter duration and less tension on the catheter body. (F) System setup for in vivo blood clot clearance. (G) Preoperative stage of the in vivo blood clot clearance demonstration. The selected segment of the carotid artery is ligated at one end and connected to a catheter sheath at the other. In the preoperative stage, the blood clot is inserted through the sheath, filling the artery to the ligature site. (H) Intraoperative blood clot clearance demonstration. The microcatheter advanced deeper every 5 min. After 15 min, the blood clot is thoroughly broken down. (I) Postoperative stage of the in vivo blood clot clearance demonstration. The blood clot has disappeared from the imaging plane and cannot be observed after inflating the blood vessel.CC BY · PubMed Central
Fig. 7. Invasiveness evaluation in human placenta blood vessels. (A) Setup of the invasiveness evaluation test. We choose four segments from the superficial blood vessels of the human placenta. In segment I, the proposed microcatheter contacts the blood vessel’s inner wall and is rotational actuated for 30 min. In segment II, the proposed microcatheter contacts the blood vessel’s inner wall and is repeatedly inserted 100 times. In segment III, a commercial guidewire is inserted into the blood vessel with tip contact on the vessel wall 100 times. Segment IV is blank control. (B to E) Example images of the histological analysis that show the physical impact on the endothelial cell layer and the inner vessel wall. The black arrows show the cell layer detachments, and the dashed line shows the torn and missing cell layer [rotational actuation and contact frictional insertion (commercial)].
Fig. 7. Invasiveness evaluation in human placenta blood vessels. (A) Setup of the invasiveness evaluation test. We choose four segments from the superficial blood vessels of the human placenta. In segment I, the proposed microcatheter contacts the blood vessel’s inner wall and is rotational actuated for 30 min. In segment II, the proposed microcatheter contacts the blood vessel’s inner wall and is repeatedly inserted 100 times. In segment III, a commercial guidewire is inserted into the blood vessel with tip contact on the vessel wall 100 times. Segment IV is blank control. (B to E) Example images of the histological analysis that show the physical impact on the endothelial cell layer and the inner vessel wall. The black arrows show the cell layer detachments, and the dashed line shows the torn and missing cell layer [rotational actuation and contact frictional insertion (commercial)].CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 79 references

Cited by

See all 40

Metadata

Authors
Zhang, M., Yang, L., Yang, H., Su, L., Xue, J., Wang, Q., Hao, B., Jiang, Y., Chan, K. F., Sung, J. J. Y., Ko, H., Liu, X., Wang, L., Ip, B. Y. M., Leung, T. W. H., & Zhang, L.
Affiliations
  • Chinese University of Hong Kong (HK)
  • Hong Kong Polytechnic University (HK)
  • Nanyang Technological University (SG)
  • University of Science and Technology of China (CN)
Corresponding author
  • Yang, Lidong
  • Ip, Bonaventure Yiu Ming
  • Leung, Thomas Wai Hong
  • Zhang, Li
Venue
Science Advances
Published
2025-06-20
Volume
11
Issue
25
Pages
eadv1682-eadv1682
ISSN
2375-2548 (ISSN-L)
OpenAlex
W4411472631
Cited by
36
References
79
Citations by year
2026: 26 · 2025: 10
FWCI
11.27
Type
journal article
Language
en
Open access
Licence
cc-by
Locations
  • Science Advances (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • PubMed Central (publishedVersion, cc-by)
  • DR-NTU (Nanyang Technological University) (submittedVersion)
  • PolyU Institutional Research Archive (Hong Kong Polytechnic University) (submittedVersion, cc-by)
Topics
  • Physical Sciences › Physics and Astronomy › Condensed Matter Physics › Micro and Nano Robotics
  • Physical Sciences › Engineering › Biomedical Engineering › Soft Robotics and Applications
  • Physical Sciences › Engineering › Mechanical Engineering › Advanced Materials and Mechanics
Keywords
endovascular access, thrombolysis, clot retrieval, active steering, soft robotics, microcatheterization, rabbit model
MeSH terms
Animals, Equipment Design, Female, Humans, Pregnancy, Rabbits, Thrombosis, Phantoms, Imaging, Endovascular Procedures, Catheters

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A magnetically actuated microcatheter with soft rotatable tip for enhanced endovascular access and treatment efficiency. https://app.cochat.ai/papers/10.1126/sciadv.adv1682
The paper
Zhang, M., Yang, L., Yang, H., Su, L., Xue, J., Wang, Q., Hao, B., Jiang, Y., Chan, K. F., Sung, J. J. Y., Ko, H., Liu, X., Wang, L., Ip, B. Y. M., Leung, T. W. H., & Zhang, L. (2025). A magnetically actuated microcatheter with soft rotatable tip for enhanced endovascular access and treatment efficiency. Science Advances. https://doi.org/10.1126/sciadv.adv1682

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.