Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 160

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Normal ranges of angiogenesis regulatory proteins in human platelets

Open access
Peterson, Jon E., Zurakowski, David, Italiano, Joseph E., Michel, Lea V., Fox, Lucius, Klement, Giannoula L., Folkman, Judah · 2010 · American Journal of Hematology

Abstract

Platelets sequester angiogenesis regulatory proteins early in tumor growth, which suggests a new avenue for monitoring disease. To date, there are no clinically relevant reference ranges for markers of early angiogenesis. We introduce a new ELISA‐based method for accurate and reproducible measurement of vascular endothelial growth factor (VEGF), platelet‐derived growth factor (PDGF), platelet factor 4 (PF4), thrombospondin‐1 (TSP‐1), fibroblast growth factor, basic (bFGF), and endostatin in platelets. To facilitate clinical applicability, the platelet levels in isolated samples were determined utilizing a new actin ELISA method. Platelets from healthy donors at single and repetitive time points were used for the assessment of normal ranges of these proteins. The physiological levels in platelets were: VEGF (0.74 ± 0.37 pg/10 6 platelets); PDGF (23 ± 6 pg/10 6); PF4 (12 ± 5 ng/10 6); TSP‐1 (31 ± 12 ng/10 6); bFGF (0.44 ± 0.15 pg/10 6); and endostatin (5.6 ± 3.0 pg/10 6). There was an excellent correlation (R2 = 0.7) between the platelet levels calculated with the actin ELISA and complete blood count. The levels of the platelets were higher than those in platelet‐poor plasma by factors of: VEGF (215‐fold); PDGF (914‐fold); PF‐4 (516‐fold); TSP‐1 (813‐fold); and bFGF (17‐fold). The endostatin levels were nearly equivalent. The biovariability of the platelet proteins in eight healthy subjects over a 5‐week period was found to be minimal. We describe accurate and direct measurements of the concentrations of VEGF, bFGF, PDGF, TSP‐1, endostatin, and PF4 in platelets of healthy human subjects. In contrast to the highly variable levels in plasma and serum, the platelet‐derived measurements were accurate and reproducible with minimal biovariability. Am. J. Hematol., 2010. © 2010 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/ajh.21732

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 160

Metadata

Authors
Peterson, J. E., Zurakowski, D., Italiano, J. E., Michel, L. V., Fox, L., Klement, G. L., & Folkman, J.
Venue
American Journal of Hematology
Publisher
Wiley
Published
2010-06-23
Volume
85
Issue
7
Pages
487-493
ISSN
  • 0361-8609 (ISSN-L)
  • 1096-8652
OpenAlex
W2038327247
Cited by
160
References
2
FWCI
4.49
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.