The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Hepatic iron stores and plasma ferritin concentration in patients with sickle cell anemia and thalassemia major
Abstract
To examine the relationship between hepatic iron stores and plasma ferritin concentration in individuals treated with red cell transfusion and iron chelation therapy, 37 patients with sickle cell anemia and 74 patients with thalassemia major were studied. In each patient, hepatic iron stores were measured by an independently validated noninvasive magnetic method, and plasma ferritin was determined by immunoassay. The correlation between hepatic iron and plasma ferritin was significant both in patients with sickle cell anemia (R = 0.75, P < 0.0001) and in those with thalassemia major (R = 0.76, P < 0.0001). Regression analysis showed no significant difference between the two groups in the linear relationships between hepatic iron stores and plasma ferritin. Considering all 111 transfused patients as a group, the coefficient of correlation between hepatic iron stores and plasma ferritin was highly significant (R = 0.76, P < 0.0001). Regression analysis found that variation in body iron stores, as assessed by magnetic determinations of hepatic iron, accounted for only ∼57% of the variation in plasma ferritin, suggesting that the remainder was the result of other factors, such as hemolysis, ineffective erythropoiesis, ascorbate deficiency, inflammation, and liver disease. The 95% prediction intervals for hepatic iron concentration, given the plasma ferritin, were so broad as to make a single determination of plasma ferritin an unreliable predictor of body iron stores. Variability resulting from factors other than iron status limits the clinical usefulness of the plasma ferritin concentration as a predictor of body iron stores. © 1993 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hahn, G. J., Draper, N., & Smith, H. (1982) · Technometrics · doi:10.2307/1267833 · Cited by 5,773
BMDP Statistical Software 1981.
Bubolz, T. A., & Dixon, W. J. (1984) · Journal of the American Statistical Association · doi:10.2307/2288308 · Cited by 5,221
Bassett, M. L., Halliday, J. W., & Powell, L. W. (1986) · Hepatology · doi:10.1002/hep.1840060106 · Cited by 664
Addison, G. M., Beamish, M. R., Hales, C. N., Hodgkins, M., Jacobs, A., & Llewellin, P. (1972) · Journal of Clinical Pathology · doi:10.1136/jcp.25.4.326 · Cited by 595
Magnetic-Susceptibility Measurement of Human Iron Stores
Brittenham, G. M., Farrell, D. E., Harris, J. W., Feldman, E. S., Danish, E. H., Muir, W. A., Tripp, J. H., & Bellon, E. M. (1982) · New England Journal of Medicine · doi:10.1056/nejm198212303072703 · Cited by 367
Self-citationPlasma ferritin determination as a diagnostic tool.
Finch, C. A., Bellotti, V., Stray, S. M., Lipschitz, D., Cook, J. D., Pippard, M. J., & Huebers, H. A. (1986) · PubMed Central · Cited by 207
The effect of erythroid hyperplasia on iron balance
Pootrakul, P., Kitcharoen, K., Yansukon, P., Wasi, P., Fucharoen, S., Charoenlarp, P., Brittenham, G., Pippard, M., & Finch, C. (1988) · Blood · doi:10.1182/blood.v71.4.1124.1124 · Cited by 168
Self-citationHematology: Basic Principles and Practice
Chesterman, C. (1992) · Pathology · doi:10.1016/s0031-3025(16)35843-3 · Cited by 147
Baynes, R., Bezwoda, W. R., Bothwell, T. H., Khan, Q., & Mansoor, N. (1986) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.3109/00365518609083733 · Cited by 133
Worwoon, M., Cragg, S. J., Jacobs, A. J., McLaren, C. E., Rickeits, C., & Economidou, J. (1980) · British Journal of Haematology · doi:10.1111/j.1365-2141.1980.tb05987.x · Cited by 89
Self-citation
Cited by
Imaging iron stores in the brain using magnetic resonance imaging
Haacke, E. M., Cheng, N. Y. C., House, M. J., Liu, Q., Neelavalli, J., Ogg, R. J., Khan, A., Ayaz, M., Kirsch, W., & Obenaus, A. (2005) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2004.10.001 · Cited by 995
Rund, D., & Rachmilewitz, E. (2005) · New England Journal of Medicine · doi:10.1056/nejmra050436 · Cited by 939
Survival in Medically Treated Patients with Homozygous β-Thalassemia
Olivieri, N. F., Nathan, D. G., MacMillan, J. H., Wayne, A. S., Liu, P. P., McGee, A., Martin, M., Koren, G., & Cohen, A. R. (1994) · New England Journal of Medicine · doi:10.1056/nejm199409013310903 · Cited by 852
Self-citationLiver iron concentrations and urinary hepcidin in -thalassemia
Origa, R., Galanello, R., Ganz, T., Giagu, N., Maccioni, L., Faa, G., & Nemeth, E. (2007) · Haematologica · doi:10.3324/haematol.10842 · Cited by 365
Vichinsky, E., Onyekwere, O., Porter, J., Swerdlow, P., Eckman, J., Lane, P., Files, B., Hassell, K., Kelly, P., Wilson, F., et al. (2007) · British Journal of Haematology · doi:10.1111/j.1365-2141.2006.06455.x · Cited by 271
Metadata
- Authors
- Brittenham, G. M., Cohen, A. R., McLaren, C. E., Martin, M. B., Griffith, P. M., Nienhuis, A. W., Young, N. S., Allen, C. J., Farrell, D. E., & Harris, J. W.
- Venue
- American Journal of Hematology
- Publisher
- Wiley
- Published
- 1993-01
- Volume
- 42
- Issue
- 1
- Pages
- 81-85
- ISSN
- 0361-8609 (ISSN-L)
- 1096-8652
- OpenAlex
- W1995879313
- Cited by
- 270
- References
- 13
- FWCI
- 4.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Hepatic iron stores and plasma ferritin concentration in patients with sickle cell anemia and thalassemia major. https://app.cochat.ai/papers/10.1002/ajh.2830420116
- The paper
- Brittenham, G. M., Cohen, A. R., McLaren, C. E., Martin, M. B., Griffith, P. M., Nienhuis, A. W., Young, N. S., Allen, C. J., Farrell, D. E., & Harris, J. W. (1993). Hepatic iron stores and plasma ferritin concentration in patients with sickle cell anemia and thalassemia major. American Journal of Hematology. https://doi.org/10.1002/ajh.2830420116
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.