CoChat

Magnetic-Susceptibility Measurement of Human Iron Stores

Brittenham, Gary M., Farrell, David E., Harris, John W., Feldman, Edward S., Danish, Elizabeth H., Muir, W. Angus, Tripp, John H., Bellon, Errol M. · 1982 · New England Journal of Medicine

The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.

Abstract

We made direct noninvasive magnetic measurements of hepatic iron stores with a specially designed superconducting quantum-interference-device (SQUID) susceptometer in 20 normal subjects and in 110 patients with liver disease, iron deficiency, hereditary hemochromatosis, or transfusional iron overload. Magnetic in vivo measurements of liver non-heme iron were closely correlated with chemical in vitro measurements in liver-biopsy specimens (r = 0.98, P less than 10(-5) up to 115 mumol per gram of liver tissue (wet weight) or more. Magnetically determined storage-iron concentrations were below 6.0 mumol per gram in iron-deficient patients and normal men and premenopausal women, but they were raised (9.7 to 31.4 mumol) in 12 of 67 patients with liver disease and were greatly increased (22.9 to 117.7 mumol) in patients with untreated hereditary hemochromatosis or transfusional iron overload. Magnetic measurements of iron stores provide a new quantitative technique for early detection of hereditary hemochromatosis and for rapid evaluation of treatment regimens for transfusional iron overload.

Overview

Integrity signals

Registry

Crossref · 10.1056/nejm198212303072703

Cites

17 of 17 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 17 references

Research works printed but not linked: 11

  1. Bauman, 1967, J Lab Clin Med, 70, 246
  2. Messer, 1967, J Lab Clin Med, 70, 1008
  3. Harris, 1978, Clin Res, 26, 504A
  4. Farrell, 1982, Appl Phys Comm, 1, 1
  5. Brittenham, 1980, Trans Assoc Am Physicians, 93, 156
  6. Richter, 1978, Am J Pathol, 91, 361
  7. Weinfeld, 1964, Acta Med Scand [Suppl], 427, 1
  8. Feldman, 1981, Clin Res, 29, 718A
  9. Brittenham, 1981, Semin Hematol, 18, 194
  10. Modell, 1979, Prog Hematol, 11, 267
  11. Marino, 1977, Physiol Chem Phys, 9, 131

Cited by

See all 368

Metadata

Authors
Brittenham, G. M., Farrell, D. E., Harris, J. W., Feldman, E. S., Danish, E. H., Muir, W. A., Tripp, J. H., & Bellon, E. M.
Venue
New England Journal of Medicine
Published
1982-12-30
Volume
307
Issue
27
Pages
1671-1675
ISSN
  • 0028-4793 (ISSN-L)
  • 1533-4406
OpenAlex
W2338855129
Cited by
367
References
17
Citations by year
2026: 2 · 2025: 4 · 2024: 2 · 2023: 3 · 2022: 2 · 2021: 4 · 2020: 1 · 2019: 6 · 2018: 7 · 2017: 10 · 2016: 9 · 2015: 6 · 2014: 9 · 2013: 13 · 2012: 7
FWCI
4.67
Type
journal article
Language
en
Open access
closed
Locations
  • New England Journal of Medicine (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Hematology › Iron Metabolism and Disorders
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
  • Health Sciences › Medicine › Genetics (clinical) › Hemoglobinopathies and Related Disorders
Keywords
hepatic iron stores, magnetic susceptibility, hereditary hemochromatosis, transfusional iron overload, iron deficiency, liver disease, liver biopsy
MeSH terms
Iron Deficiencies, Female, Ferritins, Hemochromatosis, Hemosiderin, Humans, Iron, Liver, Liver Diseases, Magnetics, Male, Methods, Tissue Distribution, Transfusion Reaction

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Magnetic-Susceptibility Measurement of Human Iron Stores. https://app.cochat.ai/papers/10.1056/nejm198212303072703
The paper
Brittenham, G. M., Farrell, D. E., Harris, J. W., Feldman, E. S., Danish, E. H., Muir, W. A., Tripp, J. H., & Bellon, E. M. (1982). Magnetic-Susceptibility Measurement of Human Iron Stores. New England Journal of Medicine. https://doi.org/10.1056/nejm198212303072703

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.