Cited by 8Ultrasound in Clinical ApplicationsInnovations in Medical EducationEmergency Medicine Education and Research

In training emergency physicians the carotid artery Doppler with passive leg raise, does previous sonographic experience influence scan time and competency?

Open access
Osgood, Robert, Mohan, Sangeeth, John, Lisa, Stirling, Erin, Stirling, Scott·2021·Australasian Journal of Ultrasound in Medicine

Abstract

Background: Determination of fluid responsiveness (FR) associated with intravascular fluid resuscitation in hypotensive patients poses a challenge, with current best evidence methods fraught with poor retest reliability and difficulty in image acquisition (Osman, Crit Care Med 2007; 35: 64; Marik, Crit Care Med 2009; 37: 2642). Doppler carotid blood flow with passive leg raise (PLR) is a recent modality for determining FR (Marik, Chest 2013; 143: 364). Purpose: This study aimed to determine whether emergency physicians with limited ultrasound experience can reliably acquire this skill. Method: This prospective study recruited 60 emergency physicians with varying experience, who underwent a 3‐step learning programme. Participants performed carotid velocity time integral (VTi) Doppler on healthy subjects, followed by repeat measurements in the PLR position. A 16‐point checklist and time recorded were assessed for each sonographer, with each participant completing a post‐study questionnaire to evaluate perceived competence and ease of skill acquisition. Results: Of the 60 emergency physicians recruited, 37 (61.6%) were inexperienced and 23 (38.4%) were experienced. Against the 16‐point assessment, 61% completed assessment without any errors. Fifty‐six out of 60 (94.3%) completed the assessment to acceptable standard with errors recognised and corrected, and four participants (6.7%) made critical errors without correction (Figure 1). Average (±SEM) total scan time was 4:52 ± 0:19, with no significant difference found between inexperienced and experienced groups. Conclusions: This study demonstrated feasibility to train emergency physicians, demonstrating that average FR assessment was obtained within 5 min, with no difference between prior experience in scan quality/time taken. 94% completed the scan to acceptable standards, demonstrating ease of carotid Doppler flow with PLR to provide critical information in management of the hypotensive patient.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/ajum.12204

Cites

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Operator experience may impact the reliability of carotid flow measurements.

    “obtaining and maintaining this mid-axis parallel view is difficult and literature describes that operator experience may impact the reliability of carotid flow measurements [2].”

    From ESICM LIVES 2023 (2023) · cites this paper as [2]

    The Reliability Parameter section (page unavailable) says differences in participants’ prior scanning experience may have altered their performance. But it also states that the study did not assess the reliability of their measurements against a gold standard; the Discussion reports no correlation between prior experience and scan quality. The paper therefore supports a possible effect on performance, not the claimed effect on measurement reliability. (LLM, conf=0.78)

    Experimental — accuracy not yet measured

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

No references could be resolved yet.

Research works printed but not linked: 17

  1. Osman D, Ridel C, Ray P, Monnet X, Anguel N, Richard C, et al. Cardiac filling pressures are not appropriate to predict hemody- namic response to volume challenge. Crit Care Med 2007; 35: 64-8.
  2. Marik PE, Cavallazzi R, Vasu T, Hirani A. Dynamic changes in arterial waveform derived variables and fluid responsiveness in mechanically ventilated patients: a systematic review of the litera- ture. Crit Care Med 2009; 37: 2642-7.
  3. Marik PE, Levitov A, Young A, Andrews L. The use of bioreactance and carotid doppler to determine volume responsiveness and blood flow redistribution following passive leg raising in haemodynami- cally unstable patients. Chest 2013; 143(2): 364-70.
  4. Mackenzie DC, Noble VE. Assessing volume status and fluid responsiveness in the emergency department. Clin Exp Emerg Med 2014; 1(2): 67-77.
  5. Wang CH, Hsieh WH, Chou HC, Huang YS, Shen JH, Yeo YH, et al. Liberal versus restricted fluid resuscitation strategies in trauma patients: a systematic review and meta-analysis of random- ized controlled trials and observational studies. Crit Care Med 2014; 42: 954-61.
  6. Marik PE. Iatrogenic salt water drowning and the hazards of a high central venous pressure. Ann Intensive Care 2014; 4: 21.
  7. Lamia B, Ochagavia A, Monnet X, Chemla D, Richard C, Teboul JL. Echocardiographic prediction of volume responsiveness in criti- cally ill patients with spontaneously breathing activity. Intensive Care Med 2007; 33: 1125-32.
  8. Stolz LA, Jarrod MM, Gross AM, Douglas MJ, Blaivas M, Adhikari S. Can emergency physicians perform common carotid doppler flow measurements to assess volume responsiveness? West J Emerg Med 2015; 16(2): 255-9.
  9. Mandeville JC, Colebourn CL. Can transthoracic echocardiography be used to predict fluid responsiveness in the critically ill patient? A systematic review. Crit Care Res Pract 2012; 2012: 513480.
  10. Mohan S, John L, Stirling E, Stirling S. Can Emergency Physicians reliably use Carotid Artery Doppler Ultrasound combined with Passive Leg Raise to predict fluid responsiveness in healthy sub- jects? Conference presentation: A Pilot study Emergency Depart- ment Logan Hospital, Metro South Health, Qld Government, Australia.
  11. Dinh VA, Ko HS, Rao R, Bansal RC, Smith DD, Kim TE, et al. Measuring cardiac index with a focused cardiac ultrasound exami- nation in the ED. Am J Emerg Med 2012; 30: 1845-51.
  12. Peachy T, Tang A, Baker EC, Pott J, Freund Y, Harris T. The assessment of circulating volume using inferior vena cava collapse index and carotid Doppler velocity time integral in healthy volun- teers: a pilot study. Scand J Trauma Resusc Emerg Med 2016; 24: 108-16.
  13. Corl K, Napoli AM, Gardiner F. Bedside sonographic regime of the inferior vena caval index is a poor predictor of fluid responsiveness in emergency department patients. Emerg Med Australas. 2012; 24 (5): 534-9.
  14. Marik PE, Cavallazzi R. Does the central venous pressure predict fluid responsiveness? An updated meta-analysis and a plea for some common sense. Crit Care Med 2013; 41(7): 1774-81.
  15. Monnet X, Rienzo M, Osman D, Anguel N, Richard C, Pinsky MR, et al. Passive leg raising predicts fluid responsiveness in the criti- cally ill. Crit Care Med 2006; 34(5): 1402-7.
  16. Torres-Macho J, Anton-Santos JM, Garcia-Gutierrez I, de Castro- Garcia M, Gamez-Diez S, de la Torre PG, et al. Initial accuracy of bedside ultrasound performed by emergency physicians for multi- ple indications after a short training period. Am J Emerg Med 2012; 30(9): 1943-9.
  17. Jalil B, Thompson P, Cavallazzi R, Marik P, Mann J, El-Kersh K, et al. Comparing changes in carotid flow time and stroke volume induced by passive leg raising. Am J Med Sci 2018; 355(2): 168-73.

Cited by

Sorted by citations

Authors
Osgood, R., Mohan, S., John, L., Stirling, E., & Stirling, S.
Affiliations
  • Logan Hospital (AU)
  • Launceston General Hospital (AU)
  • The Royal Melbourne Hospital (AU)
Corresponding author
Osgood, Robert
Venue
Australasian Journal of Ultrasound in Medicine
Publisher
Wiley
Published
2020-04-16
Volume
24
Issue
1
Pages
20-26
ISSN
  • 1836-6864 (ISSN-L)
  • 2205-0140
OpenAlex
W3017384015
Cited by
8
References
0
Citations by year
2026: 2 · 2025: 2 · 2024: 2 · 2023: 1 · 2022: 1
FWCI
0.32
Type
journal article
Language
en
Open access
Locations
  • Australasian Journal of Ultrasound in Medicine (publishedVersion)
  • Europe PMC (PubMed Central) (publishedVersion)
  • PubMed Central (publishedVersion)
  • PubMed (publishedVersion)
Funders
Emergency Medicine Foundation (EMTR‐207R26‐2016)
Topics
  • Health Sciences › Medicine › Critical Care and Intensive Care Medicine › Ultrasound in Clinical Applications
  • Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Innovations in Medical Education
  • Health Sciences › Medicine › Emergency Medicine › Emergency Medicine Education and Research
Keywords
fluid responsiveness, passive leg raising, carotid Doppler ultrasound, velocity time integral, emergency physician training, ultrasound competency, scan time, fluid resuscitation, sonographer experience

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review