Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 194

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Safety and efficacy of a novel bioabsorbable, steroid‐eluting sinus stent

Murr, Andrew H., Smith, Timothy L., Hwang, Peter H., Bhattacharyya, Neil, Lanier, Brent J., Stambaugh, James W., Mugglin, Andrew S. · 2011 · International Forum of Allergy & Rhinology

Abstract

Background: Inflammation/polyp recurrence, adhesions, and middle turbinate lateralization are causes of suboptimal outcomes following sinus surgery and lead to increased rates of revision. A bioabsorbable, drug‐eluting stent was evaluated for its ability to preserve sinus patency by providing controlled steroid delivery to the sinus mucosa. The study objective was to assess safety and efficacy of a steroid‐eluting sinus stent when used following functional endoscopic sinus surgery (FESS) in patients with chronic rhinosinusitis (CRS). Methods: Prospective, multicenter, randomized, double‐blind clinical trial, enrolling 43 patients in 2 groups. One group (n = 38) used an intrapatient control design comparing drug‐eluting to non‐drug‐eluting stents. The other group (n = 5) received bilateral drug‐eluting stents to assess systemic safety. Endoscopic follow‐up was performed for 60 days. Efficacy endpoints included assessment of inflammation, polyp formation, adhesions, and middle turbinate position. Results: Stents were successfully deployed in all 86 sinuses. Compared to the control stent, the drug‐eluting stent provided statistically significant reduction in inflammation at days 21 to 45 (p < 0.003), frequency of polyp formation (p = 0.0391), and frequency of significant adhesion (p = 0.0313). Reduced frequency of middle turbinate lateralization was also apparent though not statistically significant. No device‐related adverse events occurred. Eluted steroid was unquantifiable systemically and there was no evidence of adrenal cortical suppression. Conclusion: This study demonstrates the safety and efficacy of a novel bioabsorbable, steroid‐eluting stent for use in CRS patients. The steroid‐eluting stent is effective in improving wound healing by preserving sinus patency, reducing inflammation, and minimizing adhesions via controlled local steroid delivery without measurable systemic exposure. © 2011 ARS‐AAOA, LLC.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/alr.20020

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 194

Metadata

Authors
Murr, A. H., Smith, T. L., Hwang, P. H., Bhattacharyya, N., Lanier, B. J., Stambaugh, J. W., & Mugglin, A. S.
Venue
International Forum of Allergy & Rhinology
Publisher
Wiley
Published
2011-01
Volume
1
Issue
1
Pages
23-32
ISSN
  • 2042-6976 (ISSN-L)
  • 2042-6984
OpenAlex
W2038990945
Cited by
194
References
3
FWCI
8.88
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.