Effect of epilepsy magnetic source imaging on intracranial electrode placement
Open accessThe DOI matches its Crossref record.
Abstract
Objective: Intracranial electroencephalography (ICEEG) with chronically implanted electrodes is a costly invasive diagnostic procedure that remains necessary for a large proportion of patients who undergo evaluation for epilepsy surgery. This study was designed to evaluate whether magnetic source imaging (MSI), a noninvasive test based on magnetoencephalography source localization, can supplement ICEEG by affecting electrode placement to improve sampling of the seizure onset zone(s). Methods: Of 298 consecutive epilepsy surgery candidates (between 2001 and 2006), 160 patients were prospectively enrolled by insufficient localization from seizure monitoring and magnetic resonance imaging results. Before presenting MSI results, decisions were made whether to proceed with ICEEG, and if so, where to place electrodes such that the hypothetical seizure‐onset zone would be sampled. MSI results were then provided with allowance of changes to the original plan. Results: MSI indicated additional electrode coverage in 18 of 77 (23%) ICEEG cases. In 39% (95% confidence interval, 16.4–61.4), seizure‐onset ICEEG patterns involved the additional electrodes indicated by MSI. Sixty‐two patients underwent surgical resection based on ICEEG recording of seizures. Highly localized MSI was significantly associated with seizure‐free outcome (mean, 3.4 years; minimum, >1 year) for the entire surgical population (n = 62). Interpretation: MSI spike localization increases the chance that the seizure‐onset zone is sampled when patients undergo ICEEG for presurgical epilepsy evaluations. The clinical impact of this effect, improving diagnostic yield of ICEEG, should be considered in surgery candidates who do not have satisfactory indication of epilepsy localization from seizure semiology, electroencephalogram, and magnetic resonance imaging. Ann Neurol 2009;65:716–723
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Epilepsy surgery in children and adults
Ryvlin, P., Cross, J. H., & Rheims, S. (2014) · The Lancet Neurology · doi:10.1016/s1474-4422(14)70156-5 · Cited by 501
Electroencephalographic source imaging: a prospective study of 152 operated epileptic patients
Brodbeck, V., Spinelli, L., Lascano, A. M., Wissmeier, M., Vargas, M.-I., Vulliemoz, S., Pollo, C., Schaller, K., Michel, C. M., & Seeck, M. (2011) · Brain · doi:10.1093/brain/awr243 · Cited by 427
“…localization studies in epilepsy [particularly those using magnetoencephalography (MEG)] utilize spherical head models and subsequent co-registration of equiva- lent dipoles with the patient’s MRI using simple fiducial-based matching methods (e.g. Sutherling et al., 2008; Knowlton et al., 2009).”
MethodMagnetoencephalography: From SQUIDs to neuroscience
Hari, R., & Salmelin, R. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.11.074 · Cited by 285
A high-performance seizure detection algorithm based on Discrete Wavelet Transform (DWT) and EEG
Chen, D., Wan, S., Xiang, J., & Bao, F. S. (2017) · PLOS ONE · doi:10.1371/journal.pone.0173138 · Cited by 223
Imaging in the surgical treatment of epilepsy
Duncan, J. S. (2010) · Nature Reviews Neurology · doi:10.1038/nrneurol.2010.131 · Cited by 219
Grouiller, F., Thornton, R. C., Groening, K., Spinelli, L., Duncan, J. S., Schaller, K., Siniatchkin, M., Lemieux, L., Seeck, M., Michel, C. M., et al. (2011) · Brain · doi:10.1093/brain/awr156 · Cited by 199
“Several studies have shown that the source of the spikes that is the most electroclinically relevant represents a good indicator of the epileptogenic zone (which includes the seizure onset zone), although some patients can show discordant results (Gavaret et al., 2004; Ray et al., 2007; Brodbeck et al., 2009, 2010; Kn…”
ResultIFCN-endorsed practical guidelines for clinical magnetoencephalography (MEG)
Hari, R., Baillet, S., Barnes, G., Burgess, R., Forss, N., Gross, J., Hämäläinen, M., Jensen, O., Kakigi, R., Mauguière, F., et al. (2018) · Clinical Neurophysiology · doi:10.1016/j.clinph.2018.03.042 · Cited by 167
“The MEG findings can for example change the plan for intra-cranial electrode implantation and alter the surgical plan itself (Sutherling et al., 2008; The AAN Board of Directors, 2009; Knowlton et al., 2009).”
BackgroundDynamic imaging of ictal oscillations using non-invasive high-resolution EEG
Yang, L., Wilke, C., Brinkmann, B., Worrell, G. A., & He, B. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.03.043 · Cited by 93
“But many of these EEG/MEG studies have focused on source imaging of interictal spikes and short epileptiform discharges (Knowlton et al., 2008; Knowlton et al., 2009; Lantz et al., 2003; Minassian et al., 1999) as opposed to ictal periods, although the precise correlation of the cortical…”
BackgroundA review on brain imaging techniques for BCI applications
Bhattacharyya, S., Khasnobish, A., Ghosh, P., Mazumder, A., & Tibarewala, D. N. (2017) · Medical Imaging · doi:10.4018/978-1-5225-0571-6.ch012 · Cited by 8
Metadata
- Authors
- Knowlton, R. C., Razdan, S. N., Limdi, N., Elgavish, R. A., Killen, J., Blount, J., Burneo, J. G., Ver Hoef, L., Paige, L., Faught, E., Kankirawatana, P., Bartolucci, A., Riley, K., & Kuzniecky, R.
- Venue
- Annals of Neurology
- Publisher
- Wiley
- Published
- 2009-06
- Volume
- 65
- Issue
- 6
- Pages
- 716-723
- ISSN
- 0364-5134 (ISSN-L)
- 1531-8249
- OpenAlex
- W1987549688
- Cited by
- 152
- References
- 0
- FWCI
- 5.91
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.