CoChat

Effect of epilepsy magnetic source imaging on intracranial electrode placement

Open access
Knowlton, Robert C., Razdan, Shantanu N., Limdi, Nita, Elgavish, Rotem A., Killen, Jeff, Blount, Jeffrey, Burneo, Jorge G., Ver Hoef, Lawrence, Paige, Lebron, Faught, Edward, Kankirawatana, Pongkiat, Bartolucci, Al, Riley, Kristen, Kuzniecky, Ruben · 2009 · Annals of Neurology
Cited by 152

The DOI matches its Crossref record.

Abstract

Objective: Intracranial electroencephalography (ICEEG) with chronically implanted electrodes is a costly invasive diagnostic procedure that remains necessary for a large proportion of patients who undergo evaluation for epilepsy surgery. This study was designed to evaluate whether magnetic source imaging (MSI), a noninvasive test based on magnetoencephalography source localization, can supplement ICEEG by affecting electrode placement to improve sampling of the seizure onset zone(s). Methods: Of 298 consecutive epilepsy surgery candidates (between 2001 and 2006), 160 patients were prospectively enrolled by insufficient localization from seizure monitoring and magnetic resonance imaging results. Before presenting MSI results, decisions were made whether to proceed with ICEEG, and if so, where to place electrodes such that the hypothetical seizure‐onset zone would be sampled. MSI results were then provided with allowance of changes to the original plan. Results: MSI indicated additional electrode coverage in 18 of 77 (23%) ICEEG cases. In 39% (95% confidence interval, 16.4–61.4), seizure‐onset ICEEG patterns involved the additional electrodes indicated by MSI. Sixty‐two patients underwent surgical resection based on ICEEG recording of seizures. Highly localized MSI was significantly associated with seizure‐free outcome (mean, 3.4 years; minimum, >1 year) for the entire surgical population (n = 62). Interpretation: MSI spike localization increases the chance that the seizure‐onset zone is sampled when patients undergo ICEEG for presurgical epilepsy evaluations. The clinical impact of this effect, improving diagnostic yield of ICEEG, should be considered in surgery candidates who do not have satisfactory indication of epilepsy localization from seizure semiology, electroencephalogram, and magnetic resonance imaging. Ann Neurol 2009;65:716–723

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/ana.21660

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Knowlton, R. C., Razdan, S. N., Limdi, N., Elgavish, R. A., Killen, J., Blount, J., Burneo, J. G., Ver Hoef, L., Paige, L., Faught, E., Kankirawatana, P., Bartolucci, A., Riley, K., & Kuzniecky, R.
Venue
Annals of Neurology
Publisher
Wiley
Published
2009-06
Volume
65
Issue
6
Pages
716-723
ISSN
  • 0364-5134 (ISSN-L)
  • 1531-8249
OpenAlex
W1987549688
Cited by
152
References
0
FWCI
5.91
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.